Tel No. (+86) 371-55629010

150 mw power plant generator

(DB44/765-2019)

Recently, Guangdong Province issued a "Boiler Air Pollutants Emission Standards" (DB44 / 765-2019) (hereinafter referred to as the "standard").

A "standard" in the context of the implementation province domain for coal, oil, 65 tons of steam per hour and the material forming steam boiler burning fuel gas and raw, hot water boilers of various capacities and organic heat carrier boiler; stoker of various capacities, stoker furnace.

Second, the implementation of the emission limits of air pollutants specified in Table 1 of the boiler since July 1, 2019, since 2020 July 1 implementation of air pollutant emission limits specified in Table 2.

Third, the new boiler since April 1, 2019 (the date of the present embodiment standard) executed from air pollutants emission limits specified in Table 2.

Fourth, not the implementation of clean energy transformation of 35 tons of steam per hour and higher coal-fired boiler from January 1, 2021, implementation of the provisions of air pollutants emission limits in Table 3 in particular.

Why can steam 150 mw power plant generators exemption? You can exempt steam boilers What are the benefits? According to the "Steam Boiler Safety Technology Supervisory Regulations" provides water capacity less than 30L in the boiler does not belong to the scope of the surveillance. According to the "Steam Boiler Safety Technology Supervisory Regulations" provides water capacity less than 30L in the boiler does not belong to the scope of the surveillance. The steam generator water capacity of only 26L, like installing a home water heater as safe. So, Yinxing boiler steam boiler belongs to the exemption. You can avoid the security of small steam boiler What are the benefits? 1, you can not build a separate boiler room, can be placed in the basement, roof and other places 2, do not have a full-time duty Boilermakers (conventional boiler requires certified fireman) 3, eliminating the need for a year dealing with government departments, more peace of mind gas gas steam generators have any advantages over electric heating steam generator? Electrically heated steam generator is a small steam generating device. But steam production of electric heating steam generator is very small, and relatively low overall efficiency, the steam pressure generated steam temperature is relatively low, only suitable for use in the canteen steamed rice and the like occasions. Also much higher operating costs than on Yinxing gas steam boiler. The steam generator What are the advantages over conventional steam boiler? Steam boiler, is lower than conventional gas steam boiler safety running costs, fast start, no registration and annual inspection. Gas boilers suitable for use in what place? It can be used in hotels, factories, hospitals and other occasions. The hotel can be used as a steam boiler steam laundry places, canteens and other uses. As plant steam for a steam boiler may be used in the process. Steam boiler can be used as a hospital to disinfect hospital use. Free acceptance steam generator characteristics: 1, automatic water features: During operation, the pump automatically add make-up water, so the water level inside the work holder itself, it provides continuous high pressure steam to the external device. Without special care. 2, the triple pressure automatic protection to ensure safe and reliable devices: a weight Protection: when the body of the steam pressure reaches the upper limit of the pressure set by the controller can automatically cut off the heating power, when the body of reduced vapor pressure to the lower limit of the set , it can be automatically connected to the heating power, in order to ensure a substantially constant steam output pressure. Double Protection: the accidental causes the body to use the steam pressure exceeds the pressure limit set by the controller, the relief pressure automatically cut off the heating power controller. Triple protection: When the pressure in the pressure on the body due to an unexpected reason than the set limit safety valve, safety valve can be effective and timely release, in order to protect the safety of equipment and operating personnel. 3, dry automatic protection: accidental causes the water level falls under the level of the body, can be automatically cut off the heating power to ensure that the heating element will not be damaged due to the dry water. 4, is as a multi-chamber structure, two transition chamber by steam treatment, saturation is greatly improved, and a cool air discharging means, to ensure the quality of the steam, the steam quality requirements for higher user ideal. 5, the housing 304 drawing steel sheet, attractive and durable. 6, the control components used Schneider Electric or Siemens programmable and touch screen, reliable and durable. 7, plus turbo pump high-pressure pump, high pressure, low-power, reliable and durable. 8, a pressure and a water level automatic alarm device, a failure to timely processing.

ZG is one of biggest internal CFB 150 mw power plant generator manufacturer in China, The internal CFB Boilers plants provided in a successful operation for many years in capacities ranging from 30 to 350 MWe. Steam generators with internal circulating fluidized bed (ICFB) combustion have found acceptance throughout the world over the past few years, in particular for power generation, but also as industrial CFB power plants and cogeneration CHP stations.

As the cost of powering this equipment by burning fossil fuels has steadily risen, the use of biofuel cogeneration as a source of power production has become more prevalent. Many sugar mills have updated their bagasse-fired 150 mw power plant generators and linked them to generators that produce electricity used to power the mill’s operations and to be sold to the local power grid.