Tel No. (+86) 371-55629010

gas fired steam boiler for beer production

How how electric fired steam boiler for beer production maintenance electric steam boiler maintenance 1, boiler maintenance, must be cut off and must relief. 2, the burner every two months to be removed from the boiler, carefully remove foreign bodies such as dust and soot. Photocell light-receiving surface wipe once a month, fuel filter should always be kept clean and filtering capabilities; carefully clean the filter in the pump, do not break the seal. Oil-burner not idle, so as not to damage the pump. 3, the water level gauge should always be kept clean, rinse the purge valve is opened, the water level in order to ensure a clear day. 4, pulling the safety valve once a day, to prevent rusting failure. 5, electric steam boilers stop running long time, turn off the power, and do maintenance work: (1), dry maintenance, shutdown after the release came out water, dirt clean the furnace, with a slow fire the burner drying pot (burning time not too long, to avoid damage to the boiler), then all of the drained gas boiler, all pipe valve closed, checked every three months. (2), wet maintenance for a period not exceeding one month shutdown of the boiler, furnace shutdown after water release, discharge and clean fill with water, cut off the power, close the valve.

Six months from Hainan Sinochem Pharmaceuticals boiler equipment normally used in odd years, the equipment in good condition, our technical staff has repeatedly went to inspect the guidance. In the process of Hainan with the pharmaceutical companies, the other either for my company's product or service we are very satisfied with our company's reputation and expressed trust. --customer feedback

WNS type gas fired steam boiler for beer production system control principle: ①, after WNS type gas steam boiler on the power switch, click on the pump control switch open position, after boiler feed water rises to the normal position, click-burner power switch, clicking the start button, the control system power is on, the burner into the working state, according to the operation program for the controller, to be re-ignition burner fires into the combustion state, the boiler enters normal operation this stage. ②, high output level when the water level rose to a high level alarm signal indicator light, when the water level rises to the pump stops running + 25mm, the water pump when the water level falls -25mmm automatic restart, when the water level falls -50mm, outputs a low level alarm indicator light, with bell sound, and cut off the power to the controller to achieve protection shutdown, -75 mm when the water level falls, the output signal of low water level indicator light. ③, when the pressure is raised 0.73MPa, the output signal of the first indicator light overpressure, combustion conditions and off the controller circuit, the controller stops the shutdown. Output when the pressure rises above a second overpressure 0.75MPa signal issued bell sound, alarm and cut off the power supply control system implemented emergency stop. Regulating the pressure when the pressure exceeds the upper limit, the controller output signal of a small fire fire closed valve, a valve to open the small kerosene ignition burner. When the lower limit pressure drops below the regulated pressure, the controller outputs the fire signal to open fuel valve fire, the fire to burn. ④, after the failure of the burner failure occurs, the burner control valve is automatically shut down to stop the oil combustion. Vertical coal-fired steam boiler structural features

Gas fired steam boiler for beer production and the hydraulic classification precision classification by use gas steam boiler 1, an industrial gas steam boiler: heating and the like used in industrial production. Most of the parameters for the low, low capacity boilers, the fire bed combustion and thermal efficiency is relatively low. 2, power station boilers: mainly for power generation. Most high-parameter, large-capacity boiler, firebox and allow more efficient combustion. 3, the ship's boiler: a marine power. Such boilers generally low parameters, fuel oil, the requirements of small size, light weight, easy to move more. 4, locomotive boiler: The main use of locomotive power. Lower overall parameters are small capacity boilers, fire bed combustion, requires compact, movable. Two gas steam boiler in accordance with the kind of the working fluid and an output state classification can be divided into: 1, the steam boiler: the working fluid is steam outlet. 2, hot water boiler: hot water as the working fluid outlet. 3, special working fluid boiler: export of special working fluids, such as certain organic matter. Three outlet gas steam boiler in accordance with the pressure of the working medium can be divided into: 1, pressure boiler: the outlet steam pressure 14MPA (140kgf / cm). 2, high-pressure boiler: the outlet steam pressure 10MPA (100kgf / cm). 3, sub-pressure boiler: the working fluid outlet pressure of 2.5MPa. 4, pressure in the boiler: the outlet steam pressure of 3.9MPa (39kgf / cm). 5, supercritical pressure boiler: outlet steam pressure is about 25MPa (about 250kgf / cm). 6, subcritical pressure boiler: outlet steam pressure of 17MPa (170kgf / cm?). 7, low-pressure boiler: the outlet refrigerant pressure (gauge pressure) is less than or equal to 1.3MPa (13kgf / cm). Accuracy of the hydraulic machine, determines the precision of the parts. However, only static accuracy to measure the level of accuracy of press is not very accurate. This is because the size of the mechanical strength of the press itself has a great influence on the punching accuracy. If the strength of the press itself is low, the machine will be modified such that the pressure at the instant of Ao punching pressure is reached, so that, when the above-described conditions in a static tune even good, also since the strength of the deformation caused by the sample bed, differences occur. This indicates that the accuracy of the press and has a lot of strength, and the magnitude of the intensity of the work has a great influence on the press, so that high-precision parts and punched continuous strong cold stamping, the accuracy must be selected high, and the rigidity of the press.