Tel No. (+86) 371-55629010

12 mw coal fired steam boiler

Effect of boiler fine coal combustion boiler operating principle is to use thermal energy or heat in industrial post fuel released by combustion is transferred to the water in the container, the temperature or pressure of the water reaches a certain desired steam heating equipment. Many people will feel that coal-fired boiler more detailed the better, but is it really? From a combustion point of view, the finer coal particles more easily form a good mixing with the air, the more complete the combustion. But the coal particles too small, for boilers, milling power consumption will be greatly increased. Industrial boiler, the coal into the furnace too small, there will be the following questions: 1, coal leakage losses, etc. from grate gap increased. 2, boiler grate to be at full speed, power consumption increases. 3, fly ash, fuel loss increases. 4, a coal burning ember i.e., unstable combustion, furnace volume heat load difficult to sustain stable. So the boiler when using fine particles of coal, coal is subject to how much water, raw coal water, play groups and then into the furnace. If the burning coal of 8 to 12h before the water, so that the penetration of moisture into the interior of the coal particles is better. Water vapor produced is moistened triatomic gases, flue gas can strengthen radiation, facilitate ignition, exhaust and reduce heat loss

6 tons gas 12 mw coal fired steam boiler steam pressure adjusting a boiler operation, must frequently monitor the pressure gauge indicated. To maintain stable steam pressure, boiler pressure must not exceed the design pressure. Second, increasing boiler load: Steam pressure decreased boiler load is increased, if the level is high at this time, the amount of water should be reduced to a water supply or suspend, the amount of coal and increase the air volume. Gradually increase the amount of water at the same time to strengthen the burning, keep the steam pressure and the water level is normal. Third, the boiler load reduction: the vapor pressure rises to reduce boiler load, if the level is high at this time, the amount of coal should be reduced and the air volume, reduced combustion. Then the appropriate water reduction or suspension of water supply to the water vapor pressure and stability in the nominal range. Then press the normal combustion and the amount of feed water 8 to adjust. If the actual water level within the boiler is low, to increase the amount of water should, until the water level returns to normal after the combustion and needs to be adjusted according to the water vapor pressure and load changes.

Cade Shopping Mall is located in central Shanghai Hongkou District, Shanghai Daily larger flow of people in the region. The introduction of Shanghai air pollutant emission standards, boiler flue gas emissions of nitrogen oxide emissions to less than 80 mg / m, Shopping Mall a coal-fired boilers have been used for many years, NOx emissions far super to this request, the urgent need to replace more environmentally friendly low nitrogen emission boilers. Other units through the use of fast Boiler introduction and understanding, determined and fast boiler to achieve cooperation, party fast to their specific needs to recommend one condensing gas hot water boiler of a 4.2MW for heating needs of the shopping center.

The third reason is that the amount of nitrogen oxide released during operation is very small. Most heating equipment such as ordinary boilers need to use coal materials as raw materials when they are in operation. Materials such as coal generally release a large amount of hazardous air-quality substances when burned. The condensing boiler uses the steam produced by natural gas combustion as the raw material when it is in operation, so the nitrogen oxide content released during the operation is much lower than the prescribed standard. The analysis of the reason for the year-by-year increase in the sales of condensing boilers has come to an end for the time being.