Tel No. (+86) 371-55629010

Automatic Ignition Straw Pellet Fired Boiler Raipur

On the gas automatic ignition straw pellet fired boiler raipur, if it is 1 ton of water, then heat the temperature of progress once the demand is 1,000 calories, but this time, can reduce gas consumption. If the natural gas heating value is 8600 kcal, then the above problems can be obtained through the calculation is concluded, each producing 8.6 tons of hot water, it can save the amount of natural gas is of 1 m.

2.10 tons boiler, the amount of natural gas consumed per hour, how much is? Different auxiliary boilers are equipped with the same right?

10 tons of boiler, which is on the calorific value, the equivalent of 6 million kcal. Therefore, if the heat value of natural gas in accordance with the calculation to 8600 kcal, then its consumption of natural gas per hour, is about 700 cubic meters. And on the issue of two, whose answer is NO, that is, different boilers, auxiliary equipment, it is not the same.

3. The dual-pressure waste heat boiler, in which steam pressure and temperature, what are the conditions? In addition, the condensed water temperature is too high, what should I do?

"Wet back" Gas-fired steam automatic ignition straw pellet fired boiler raipur Description: Henan party fast production of gas boilers have been all over the country, Southeast Asia, the Middle East, South America and other places have also used the Henan party fast product description Henan party fast production of boilers have been domestic and foreign for recognition. Among the many products, I want to say is that a product gas boiler, gas boiler which when introduced advantages, there is such a word to say; wet back structure, full board edge butt welds, high reliability, low maintenance costs, what is wet-back structure is wet back boiler transfer means move inside the smoke chamber of the boiler drum, transfer the smoke chamber of the tube plate, the back plate and the cylindrical body are surrounded by pot of water (i.e., immersed in the furnace water), so called wet-back (also known as water-back).

Gas fired steam automatic ignition straw pellet fired boiler raipur pressure is not on what causes? Gas fired steam boiler is not very common on the pressure, the main cause of 1, if the pump is working properly. 2, the pressure gauge is broken. 3, the check valve is blocked. 4, whether to reverse the induced draft fan. Mainly caused due to the above four reasons. Users have been asking how to burn gas steam boiler do not increase the pressure, there are a lot of factors, and today we talk about a few of these factors. First, check to see if the pump work, can achieve much pressure pump, pump installation is going to be a pressure gauge installed in the pump above, this is because, if the increase to no water inside the steam boiler can detect whether it is caused by reason of the pump . Pressure gauge to detect what is not broken. Check whether the induced draft fan reverse, users have encountered this situation, the beginning is very anxious to buy gas fired steam boiler has been not on the pressure, so he checked the pump, check valve, no problems, after his inspection induced draft fan is not inverted, after examination revealed induced draft fan power line reversed, and after adjusting all normal. After the situation encountered gas steam boiler is not burning on the pressure do not worry, first check the steam boiler attachment which is not connected to the wrong place or method of operation requires no installation operations, after then contact technical personnel.

In recent years, the state environmental protection is all the more attention we as a company with the times, in order to respond positively to the implementation of the national environmental protection requirements from coal to gas project. But the choice of automatic ignition straw pellet fired boiler raipur suppliers in this area quite a headache, after repeated comparison and investigation, we chose to partner with fast boiler. Fang did not disappoint quickly proved that the recommended boiler operation after use to fully meet our needs, both energy saving and environmental protection, high thermal efficiency, to a certain extent, cost savings for our fuel. --customer feedback