China coal hot water boiler prices

To further promote the comprehensive management of coal-fired boilers, Jincheng City, Shanxi Province, according to "Jincheng Blue win the Battle of three-year action plan" requirements, plans to complete 109 units of 10-20 tons of steam "small coal-fired boilers" within this year the phase-out, at the same time, Jincheng will start working out of 35 tons of steam coal-fired boilers.

This year, Jincheng counties (cities, districts) the environmental sector will urge the relevant enterprises and institutions to eliminate the basis of 10 tons of steam and coal-fired boilers on in 2018 to accelerate the phase-out and 20 tons of steam coal-fired boilers. This year, the city to complete 109 units (10-20 tons of steam boilers) working out of a total of 589.5 tons of steam boilers; at the same time, Jincheng will also speed up the foundation and 20 tons of steam coal-fired boiler out, start 35 tons of steam phase out coal-fired boilers, in principle, within the city's new domain-wide 35 tons of steam coal-fired boilers.

In addition, Jincheng will accelerate the transformation of ultra-low emission. Before the end of September this year, the city will complete 52 units (65 tons of steam per hour and higher coal-fired boilers) coal-fired heating boilers ultra-low total of 4530 tons of steam boilers transformation, and the county (city) built-up area, biomass boilers emissions transformation. After transformation, under condition of the reference oxygen content of 6%, soot, sulfur dioxide, nitrogen oxides emission concentration of these boilers respectively not higher than 10 mg / m, 35 mg / m and 50 mg / m.

Transformation of low nitrogen in the combustion aspect, before the end of October, Jincheng station 610 will complete the transformation of low-nitrogen combustion Total 1940.15 tons of steam gas boiler, after completion of the transformation, the boiler NOx emission will not exceed 50 mg / m.

Gas boiler SZS, WNS, F, A, L, N, B and other parameters have what meaning? SZS gas boiler water is commonly used parameters. Wherein the meaning of each letter, S: double drum. There are two drum boiler, goes under the distribution structure. Z: vertical type. Using the "D" type arrangement, arranged longitudinally down drum, as the flue gas flow partition Wall full mode, the left side of the boiler convective tube bank is arranged. S: combustion chamber. Fuel is powdered (solid fuel, such as coal), mist (liquid fuels, such as oil), gaseous (gaseous fuel, such as natural gas) along with the air into the furnace (combustion) combustion in suspension. WNS is automatic gas (oil) parameters commonly used boiler. In which the meaning of each letter, W: horizontal. A boiler according to the design and installation of the outer layout, was lying state. An exhaust gas stream produced by the boiler is of horizontal flow, the flow of hot gas, in the same section on the exhaust gas temperature is low compete. N: internal combustion. After all of the fuel combustion flue gas, without burning the residue was heated with a heating surface directly mixed working fluid (water), and the flue gas, steam as the working fluid work output, the flame in the combustion furnace through the center of the drum. S: combustion chamber. Fuel is powdered (solid fuel, such as coal), mist (liquid fuels, such as oil), gaseous (gaseous fuel, such as natural gas) along with the air into the furnace (combustion) combustion in suspension. F: split. A: three return. N: N is low. L: condensation. B: Center backdraft.

Power plant: utility boiler burning coal with various power, natural gas, heavy fuel oil, coke oven gas blast furnace steel plant, biomass (straw, rice hulls, coconut shells, sawdust, etc.), waste rock, shale oil, petroleum coke, water treatment plant sludge, garbage and so on.

How to provide boiler thermal efficiency thermal efficiency of the steam boiler has the following methods: low-pressure boiler at the factory has been designed considering the problem of thermal efficiency of the boiler, the flue gas from the device or change little aspects of energy-saving possibilities, it is best to start from the energy-saving operation (here talk recovered water vapor condensation method). The current design thermal efficiency of domestic low-pressure boiler is generally 70 to 90%, generally the actual operation of the thermal efficiency of about 60 to 80%, some even below 50%, a small low pressure industry as long as the operation, maintenance properly, can meet the design thermal efficiency of manufacturers. I think the management and operation should pay attention to the following points: First, the boiler flue gas temperature monitoring. Typically the maximum exhaust heat loss is loss, it is important to good control of exhaust gas temperature, exhaust gas temperature is generally low pressure coal-fired boiler of 150 ~ 180 ℃, fuel boiler exhaust gas temperature is 210 ~ 240 ℃, so when the boiler to find out why when the exhaust temperature is too high and promptly eliminated. Coal-fired boiler flue gas temperature is too high reasons are: high furnace pressure; shorting smoke; thick soot on the heat pipe; thick scale pot like. High temperature fuel exhaust reasons are: 1 air not adjusted oil, the oil is not completely burned in the chimney the secondary combustion occurs aft; 2 soot too, the need for timely cleaning; 3 shorting smoke; 4.... thick scale; Second, controlling blowdown rate. Without restricting the general rate of industrial sewage control in 5 to 10%, in the pot of water to ensure that qualified (mainly total alkalinity and pH value), the blowdown rate as low as possible, the sewage to adhere to the "ground row, row less, are ranked "the rules. Third, the maintenance of good furnace wall insulation. The heat loss is also a relatively large heat losses, now the manufacturers in the manufacturing and design has been well thought out, so we do not need to change, we just trying to be difficult to maintain. Outer surface temperature generally does not exceed 50 ℃, it will have to find out the reasons such as too high, and remove. Boiler insulation should always be kept dry, for coal, not a long positive run, or easy to damage the coal furnace wall and gate and so on. Fourth, adjust the ratio of fuel and air volume, complete combustion of the fuel as possible. Generally do not have a small amount of wind testing instruments, we can only go by experience adjustment. For oil, the normal combustion flame was yellow-white, non-glare, flame stability, no visible smoke chimney; For coal, the normal combustion flame pale, no visible smoke chimney, basic cinder burn coal particles as even as possible. Fifth, the need for a sound water treatment. Improve water treatment and water quality testing can maximize prevent fouling and correct guidance of the sewage, but it did not do a lot of small, companies usually do not pay attention.