Tel No. (+86) 371-55629010

6 Ton Steam Boiler Russia

Large hotel rooms with big gas boiler: current gas-fired boilers within the city limits is one of the most widely used universal equipment, to introduce the next chapter focuses on how to choose the most suitable for large hotels gas boiler model: First, we quickly sell the shares in accordance with Henan party to the gas heating boiler, a large bath for example, to share with the whole process is the hotel of how design is a large bathing places total rooms have 340 rooms, including 160 standard rooms, there are 100 single rooms, cheap there are 80 rooms, Henan party then quickly given by customers bath with hot water usage to calculate the consumption of hot water per day through a statistical average, customers at the hotel everyone bathing water is a 80L, if all the rooms to live in accordance with standard full count the total water consumption is calculated as follows: (160 * 2 + 100 + 80) * 80 = 40000L, and is often calculated based on the tonnage of the boiler, the volume of water equal in terms of tonnage 1L 1kg, so the daily water the amount is calculated on the amount of water 40000kg needs.

Speaking from personal interests, this approach not only to minus expenses chemicals can also be removed from water analysis personnel expenses, but not fundamentally solve the problem of boiler scale and corrosion, but not only resulted in a waste of energy also reduces the life of the boiler.

In the specific implementation process should pay attention to a few points:

1, according to the strict rules of water treatment, to ensure acceptable addition salt supply, to reduce the impurities in the water, to reduce the water vapor thus reducing the salt content of the salt furnace, to ensure good quality feed water.

2, reasonably boiler blowdown. Boiler blowdown discharge points periodically and continuous blowdown, periodic blowdown of boiler water can be eliminated and the precipitate slag. Continuous blowdown pot of water can reduce the amount of salt, silicon content. Therefore boiler attendant should be carrying out the work of the technical measures for emission standards for technical and operational breakout strictly enforced.

3, according to the technical standard boiler regulations: strict control of boiler water level normal, caused by high water levels prevent steam with water, resulting in the deterioration of the quality of steam. Also, avoid sudden changes in the load, in order to avoid false water level caused by the sharp increase in water level in a serious deterioration in the quality of steam.

4, water quality requires stringent requirements, real-time adjustment of boiler operating conditions. Because soda boiler monitoring indicators to determine the chemical experiments of each heat boiler, the operation should remain qualified soda quality.

Fangkuai Company has a fully-automatic PLC intelligent control system designed and developed by itself with complete intellectual property rights. It adopts a combination of mechatronic control equipment and a programmable logic controller (PLC). Take the advanced programmable logic controller (PLC) as the "central processing unit" of the control system. The control system is operated through the touch screen, which greatly improves the degree of automatic control and operation reliability of the boiler, and the operation is simpler and more intuitive.