Tel No. (+86) 371-55629010

biomass hot water boiler for hotel

Wood waste water tube steam boiler is a kind of biomass fired steam boiler, which mainly takes biomass energy as its fuels, such as rice husks, straw, tree branches, firewood, corn cob, cane bagasse, lees, palm shell and other wood waste as its fuels.

Di steam boiler safety valve installation and adjustment of safety valves for steam boilers, its importance is self-evident, its purpose is to protect the safe operation of steam boilers, when the medium pressure steam boilers or pipes increases more than the prescribed the value is automatically turned on, the steam boiler safety shutdown. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass biomass hot water boiler for hotel, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. There are heating and hot water boiler bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Safety valve is so important, then for its installation, precautions, the author based on years of experience, in particular, are summarized below. 1. The safety valve safety valve should be installed after the installation of the boiler pressure test and adjust safety valve operating pressure at the first fire. The pressure should 7≤2 provided for in section 143 of the National Bureau of Labor Table "Supervision and Regulation steam boiler safety technology" to adjust. 2. Remove the adjustment valve opening pin, remove the cover, loosen the hex lock nut, the adjustment screw is then screwed, to relax or tighten the spring to meet the required pressure exhaust valve. After adjusting tighten the lock nut, and then install the remaining components. When the valve reaches a predetermined set pressure, it should be sealed lead-sealed, unless the check valve, otherwise not allowed to remove the lead seal at any other time. First, when adjusting the safety valve, the water level should be slightly lower than normal water level of the barrel, and ready to enter the water when the safety valve is opened. Second, do not knock any part of the safety valve, the safety valve can only be opened using the valve control lever. Finally, the boiler is absolutely prohibited until the safety valve is adjusted.

4 large superior protection systems protect the water steam boiler steam boiler is provided with two pumps, run and standby. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass biomass hot water boiler for hotel, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. Boiler plate with one or two level timing, should always be compared with each other, find instruction inconsistent, it must be corrected immediately. Each class should rinse water level gauge to determine its true level. And also has balanced water pipe poles can accurately capture level signal or alarm to the pump control. 1, a pressure protection when the boiler pressure exceeds the vapor pressure protection rating, it is necessary to chain protection: is shutdown, the system stops the combustion; nozzle can be replaced, a single stage or two stage combustion, the amount of oil can be adjusted. , thereby reducing the pressure to ensure the safe operation of the boiler. As water pressure protection with protective oil (gas) steam boilers, the use of multiple protection: (1) the pressure controller typically uses two pressure control pressure signal into an electric signal electromechanical conversion device, which is a function of the high and low pressure signals to electrical switches, and the automatic control circuit or an external interlock protection. Normal pressure controller and make electrical contact pressure gauge vapor pressure and overpressure alarm off burner limit is reached, the pressure controller adjusts single or double fire burning fire based on the actual pressure. For large burner, the fuel can be adjusted according to the amount of pressure, the pressure is always maintained in a stable operating state. (2) is the last line of defense to protect the safety valve of the boiler. When the boiler pressure exceeds the limit, according to the set pressure relief valve design, releasing exhaust pressure, in order to ensure the normal operation of the boiler. 2. Temperature protection is an important part of the process of the safe operation of the boiler, especially for steam boiler temperature regulation and protection. While achieving regulation and protection function of the hot water boiler superheater. Conventional boiler temperature protection means is a bimetallic temperature controller 3. Flameout protection against furnace explosion. Oil (gas) boiler must be equipped with flame protection device, and its function is combustion monitoring furnace (including an ignition when the ignition failure or extinguish combustion, typically re-ignited within five seconds, runs in one second, closed oil ( gas) solenoid valve, is opened concurrent silent alarm signal, the blower continues to operate at this time. after the furnace was purged of combustible residual gas, after purging two thirty seconds, the fan and various auxiliary power cut off, stopping the boiler operation.) by a flame monitoring device and control components. Flame monitor display function is to signal the presence of a flame or an interrupt from the control device. Its main purpose is a photomultiplier tube, a photovoltaic cell and photosensitive resistance, they have an ultraviolet or infrared type photoelectric conversion element, its working principle is converted to the corresponding light radiation intensity of the high current and low current. And a linear output state, the induced current is sometimes weak, and thus affect the controller amplification. 4. The self-locking power failure protection in case of sudden power failure, the boiler operation immediately closed self-locking, if the current power is restored, start at any time, must be reset to unlock in order to re-start the ignition. Imported monochrome color touch screen control system, fully automated operation. Having automatic water supply, water, over-temperature, over-voltage, automatic power failure alarm, leakage protection security systems.

Under the guidance of our customers professional and technical personnel, the full solution of the fast square excellent products and brand strength, our company is very interested in several steam products, finalized the purchase of three 1.25MPa, respectively 2 tons of steam , 4,15 (WNS2 / 4 / 15-1.25-YQ) and two 1.6MPa, steam tons the amount of 4,10 (WNS4 / 10-1.6-YQ) integrated condensing gas boiler steam, and hope to establish with our company long term cooperative relations.