Tel No. (+86) 371-55629010

water tube szl boiler

2: Temperature for steam water tube szl boiler efficiency:

(1) the outside temperature differences in the winter and summer will be 20-50 ℃, affect the industrial boiler exhaust gas temperature 10-30 ℃, the impact on the steam boiler efficiency shall be 1% -2%. The difference between day and night will be around 10 ℃, affect the steam boiler exhaust gas temperature shall above 5 ℃, the impact on boiler efficiency shall around be 0.3%.

Hot water water tube szl boiler maintenance method which hot water boiler hot water boiler maintenance methods if poor maintenance during outage or maintenance, the harm is great. Thus, the boiler shutdown should first remove the drum, the angle circle header, the internal pipe and the external wall and smoke vertical boiler scale, slag and all dirt. Fouling and cleaning inside the furnace water wall tubes and convection inside the smoke tube Huigou and boiler maintenance should be performed. Around its maintenance methods commonly used the following two methods. 1, wet maintenance: taking with a sufficient concentration of the alkaline solution in contact with the metal surface of the boiler, the alkaline metal surface to form a protective film to prevent corrosion in the metal. Usually of NaOH, Na2CO3 or formulated as protective Na3PO4 solution (NaOH per ton of oven 8 to 10 kg of water was added, Na2CO3 per ton 20 kg boiler water, boiler water Na3PO4 per ton 20 kg). The specific method is: the boiler all valves, baffles, manholes, hand holes, inspection door is locked, then the good previously dissolved NaOH, Na2CO3 or Na3PO4 solution was added to the boiler, the boiler and then filled with demineralized water. Alkali concentration in the furnace is the water released alongside consistent water gas (mainly O2 and CO2), the furnace may be raised Microflame warming (warmed before, the air valve to open the boiler, without air valve, safety valve available Instead of or relief valve) boiling water into the furnace, so that a natural circulation boiler water. After completion of the air valve (relief valve or safety valve) exhaust gas, and then close the air valve (relief valve or safety valve), then turn off the fire. Boiler water once a week should test to ensure that there is excess boiler water alkalinity. If insufficient alkalinity, should be added NaOH, Na2CO3 or Na3PO4.2, dried maintenance: desiccant absorbs moisture, boiler holding surface drying, to prevent corrosion. Lime (CaO) or anhydrous calcium chloride (of CaCl2) are commonly used as a desiccant. Specifically, the following: After the inner and outer surfaces clean boiler, boiler with Weihuo drying, then open wooden box containing a desiccant into the drum, the header, and furnace flue. The amount of the desiccant is determined according to the volume of the boiler (with large lime, in the boiler 2 to 3 kilograms per cubic meter, if anhydrous calcium chloride, from 1 to 2 kilograms). Then close all valves, flapper, check door, hand holes and Manhole prevent intrusion of external moisture. During the maintenance of open manholes, hand holes and door on a regular basis. If the desiccant is invalid, it should be replaced.

There are steam water tube szl boiler plant yellow water several reasons for it: the steam boiler burning equipment, water appears yellow case, is the following eleven due to lack of water pH of the steam boiler plant, the water quality will certainly appear Piansuan case, generally speaking, all parts of the entire inside of the boiler has some corrosive conditions, in this case, the situation will naturally appear yellow. Saturation vapor pressure of the steam boiler plant is how strong regulation of gas boilers | oil-fired boilers | steam boiler Environmental Equipment Co., Ltd.

On January regular press conference, Secretary, Ministry of Environment environment atmosphere Liu Bingjiang said: Through the joint efforts of the whole society, national ambient air quality is generally improving. But issues of current emissions of air pollutants is still high, industry structure, energy structure is still prominent, air pollution control remains to be done.

2019 is to win the battle of the blue sky in tackling it. China Environmental Science Research Institute Professor Xue Zhigang said China is still partial to change the energy mix of coal to Beijing and Tianjin, for example, though not local, but coal consumption per unit area of ​​5 to 6 times the national, so to adhere to focus total coal consumption areas under control.

First, the structure of coal-based energy, coal pollution characteristics significantly. Shaanxi, Shanxi coal-producing province is also the province's coal consumption, coal consumption Fenwei plain more focused, coal accounted for nearly 90% of energy consumption, much higher than the national average of 60%.

Second, the emphasis on regional industrial structure, industrial pollution emissions from large. Fenwei plain alumina, coke, iron and steel, coal, chemical and other heavy chemical industry, small-scale enterprises, low level of equipment, and most enterprises have yet to achieve a stable discharge standards, ultra-low emission completion percentage less than the transformation of thermal power enterprises in Beijing, Tianjin the level of pollution control needs to be improved.

Third, the prominent road transport pollution, emissions from large heavy vehicles. Fenwei plain is an important channel Shaanxi, Inner Mongolia and Shanxi coal Sinotrans, common to road transport, heavy industry-oriented industrial structure to further increase the pressure of road transport.

Hebei Province in 2019 government work report, determined to win the battle of the blue sky, ultra-low emissions to accelerate the transformation of key industries and promote clean coal casual alternative, "scattered dirt" dynamic business continuity cleared, Hebei Province, the year will be 10 million tons of coal Yajian thermal power 500,000 kilowatts.

Tianjin in 2019 to promote low-nitrogen transformation and construction work clean diesel transformation of mechanical gas-fired boilers, in an orderly urban and rural residents clean alternative to coal for heating, PM2.5年均浓度持续下降. In addition, Guizhou, Gansu, Heilongjiang and other places have made the coal control target.

It is reported that, after the heating season this year, the Ministry of Environment will work with ecological scientific and reasonable arrangements around 2019 bulk coal management plan. Regional authorities will further strengthen joint prevention and control, continue to implement the autumn and winter tackling action in key areas. In the future, China will focus on promoting the Beijing and Tianjin and the surrounding areas, as well as bulk coal governance Fenwei plains, to the 2020 heating season, the basic completion of the plains to live and bulk coal for heating in winter instead.