Tel No. (+86) 371-55629010

8 Ton Gas Boiler Machine

Recently, the Tianjin Municipal Government issued the latest "2018 ~ 2019 autumn and winter tackling air pollution comprehensive management action plan" (the "Program"), "plan" put forward specific remediation requirements: the city's 65 steam tons / hour and above the basic realization of coal-fired 8 ton boiler machines coal-fired power plant ultra-low emission standards, the development of energy-saving and ultra-low emissions rehabilitation programs for 65 steam tons / hour or more coal-fired boilers, the implementation started after the end of the heating season. Before the end of this year, within the city basically eliminated 35 tons of steam / h and coal-fired boilers of 25 iron and steel industrial enterprises discharge waste depths of governance, the basic completion of the iron and steel, building materials, thermal power, coking, casting and other key industries and coal-fired boiler fugitive emissions control.

"Plan" the implementation process to uphold the objectives warm winter and clean heating double standards, combined with the actual development of coal-fired boiler rehabilitation programs, to ensure completion before the end of the year 206,100 rural residents to use clean energy alternative to coal for combustion. Guidelines established after the first break, for the substitution of gas for coal to electricity instead of coal and other alternatives, in the case of gas supply, power supply is not implemented, the existing heating facilities will not be dismantled until the gas supply, power supply after the successful implementation be removed. And to develop high-pollution fuel combustion zone ban zoning adjustment programs, complete with electricity instead of coal, substitution of gas for coal in the region included the range of high-pollution fuel combustion zone ban. For failure to implement the heating area clean, good smokeless coal tender, production, supply, to ensure smokeless coal substitute the existing polluting large coal-fired boilers. Among them, before the heating period to complete large-scale centralized distribution, heating Doing the fragmented coal blending, before the end of December 2018, the actual realization of bulk coal dealers cleared.

With such a steam 8 ton boiler machine now been applied, so now this boiler equipment, can be said to be able to get among the many enterprise application, so now select the boiler equipment, it becomes a very important thing. In such a device for selected time, taking into account the efficiency of the performance of equipment, facilities, and there is now power energy equipment, because now the boiler equipment, began to appear in coal, natural gas and electricity and other energy sources, it is also It enables businesses can now go to select.

IBR Small industrial 8 ton boiler machine in factory

IBR Oil or Gas Fired Boilers :

Master these techniques can prolong the life of your 8 ton boiler machine low nitrogen, is determined not to look at it: low-nitrogen boiler is in obvious advantages on the basis of environmental policy and saving money on, are widely used. But there are many business units are new low nitrogen boiler, for how to operate properly and prolong the life of the boiler, and not very good grasp. Fast boiler professional production of low nitrogen boiler, summarizes the following three extend boiler life low nitrogen tips to help users better operating low nitrogen boiler. 1, low nitrogen good power boiler inspection work is the driving force of energy in industrial production, before use, you must first do a good job security and troubleshooting, power checks and maintenance work, in order to ensure the safety of high-speed operation and boiler operator; in addition , but also on the part of a full range of equipment and inspection work, to make the life of low nitrogen boiler becomes longer. 2, the holding device periodically to check whether dried and smoke when a low nitrogen boiler tube patency after completion, the operator should be promptly cut off the power, and when the apparatus until the temperature drops, dust and dirt need to clean the housing, but also to boiler placed in a dry and ventilated place, the next device in order to ensure the normally open, secondly, due to the low nitrogen boiler exhaust gas is carried out primarily by the threaded pipe, so that the operator using this device, after completion, then periodically cleaning the smoke pipe, to avoid being blocked by dust and affect their effectiveness. 3, regularly adding parts in time to make the right judgments and processing lubricants low nitrogen boiler in the low load operation, the supervisory inspector must concentrate on strengthening the analysis of each instrument, abnormal situation, in order to ensure the boiler normal operation and prolong its service life; in addition, also regularly add the oil to low nitrogen in various parts of the boiler, the boiler can reduce the running resistance, improve production efficiency.