Tel No. (+86) 371-55629010

10t Gas Boiler Price Ukraine

Gas oil furnace and expansion tank should pay attention to what effect the high slot: the gas oil furnace, I believe we will not feel strange, but should also have a certain degree of knowledge and understanding, if the box has been concerned about the 10t boiler price ukraine site, and at the same time to carefully read the relevant article, and at the same time, to grasp their knowledge of words. So, based on this, then, we will continue this work, to promote a good learning process of the product, and so that everyone from a new harvest and inspiration. 1. Gas conducting oil conducting oil furnace exhaust port, which is typically what position the boiler on? HTF HTF furnace gas exhaust port, generally speaking, at the top of the boiler, i.e. high boiler shell. Furthermore, in this site, as well as the seat member, it is mainly used to install safety valve. Moreover, this drawing on the boiler, also will be marked out, as long as you can read drawings, you can, so can avoid making mistakes. 2. Gas expansion slot conducting oil furnace, which is in use, should pay attention to what issues? Gas expansion tank of oil furnace, the origin of their name, in part because of the boiler will heat transfer oil into the expansion slot, the expansion play a role. And this means that during erection, caution needs to be done is, it can not be damaged or broken. In addition, the oil level in the expansion tank, should be well controlled, so as to ensure the normal operation of the boiler.

How to maintain the 10t boiler price ukraine shutdown? After boiler shutdown cooling, heating surface must be thoroughly cleaned of fouling and ash grate the upper, the lower portion of the furnace. Then to maintain a certain degree of natural ventilation flue. In general, in order desiccant moisture should be placed in the furnace, flue. The quicklime as a drying agent, within the furnace or flue gas per cubic meter should be placed generally about 3kg. After placing all the ventilation should be tightly closed doors. After the change of lime powder to be replaced. Low-lying position as boiler room, ground during shutdown severe flood tide, often approach should be used and placed a small fire to dry desiccant combination. How to care? If the boiler shutdown a long time, the boiler shutdown after complete removal of soot coated with an anti-corrosion red lead paint in oil or other metal surface furnace. As internal corrosion Maintenance shutdown of the boiler body, under normal circumstances, can be used wet shutdown maintenance is not more than one month, one month electrically operated steam boiler should be taken to dry more maintenance. To note the following problems when a dry maintenance: desiccant boiler not in direct contact with the metal surface, may be mounted in a container such as the iron plate after the desiccant is placed, and a hole for shutting the other hand hole cover.

Gas 10t boiler price ukraine safe handling as the country increasingly stringent emission standards for air pollution, the country has already started work boilers from coal to gas, out of heavily polluting coal-fired boilers, gas boilers using clean fuels. In this regard, Kono Tips boiler, gas boiler process, the need to pay attention to some safety issues: 1. burner to keep the working environment clean and dry, burner cleaning and maintenance once per shift to the control circuit must not get wet, affected by high temperature. 2. Check the electrical installations, mainly: whether the damaged wire, jacket damage, without loosening the screws, the contact is good, the motor is running any abnormal sound. 3. During normal operation, the burner portion close to thermodynamic device (such as a flange connection part) will be very hot, to avoid burns. Do not place near flammable materials, so as not to cause a fire. 4. combustor during startup, if the burner is locked repeated alarm reasons should be identified, and then identify failures and excluded press the reset button (pressing the reset button must not exceed 10 seconds), continue to start. 5. After the total gas pipeline experienced a temporary power failure solenoid valve (steel tile shed) to stop gas supply will automatically shut down until the first call burner electric alarm device to send, then a small hammer solenoid valve with total on hand to pull, you must first send electricity to manually open solenoid valve, solenoid valve will be closed and vice versa total. 6. fireman not mess-tune the burner, abnormal promptly notify management personnel, approved by management and then make adjustments. 7. In the long-term shutdown state, to do maintenance work on the boiler equipment, for each transmission parts to clean, lubricate.

The competition, the segment is slowly 45 contestants only a female welder, most of the other competitors from China Electric Power Construction, veteran welders in the petroleum, petrochemical, and other large number of country prefix units, with a very rich practical operation of work experience. Faced with numerous welding expert, slowly segment did not flinch and fear, but to actively exercise their welding ability, the old master who humbly ask to try a variety of different welding methods, and repeat the training to do practice makes perfect. By her welded 10t boiler price ukraine parts forming the United States, no weld defects neat; in her station, welding clean, neatly stacked tools, work order. It is because of her usual work down to earth, hard work and practice, lay a solid foundation for the success obtained.