Tel No. (+86) 371-55629010

8t Seller Industrial Boiler Lithuania

To speed up solving air pollution prevention and control Liaoyang key and difficult issues, Liaoyang city government combined with the actual circumstances of the sky to win the Battle of implementation. Details are as follows.

1, promote clean heating. To proceed from reality, should the electric power, gas should the gas, the coal should be coal, should be hot is hot, warm winter to ensure the safety of the masses. In strict accordance with the "Notice on and of" (Municipal Office Liao Fa [2018] 19) requirements, minutes from the town to the countryside level steady implementation of clean coal-fired heating, natural gas heating in an orderly way, actively promote electric heating, heat pump heating scientific development, expansion of industrial waste heat heating, heating to accelerate improvements in the proportion of clean, implement the relevant provincial price policy, ensure the power supply. 2019 Clean heating rate should reach 44% in 2020 to clean the heating rate should reach 49%.

2, control total coal consumption. According to energy-saving emission reduction Work Leading Group Office of the City "on the issuance of Liaoyang control total coal consumption program of work (2018-2020 years)" (City of Liaoning Office Savings Fa [2018] No. 3), the city's total coal consumption do control. Vigorously for shutting down energy consumption, safety, environmental protection and other 300,000 kilowatts coal-fired units of non-compliance, capacity indicators for shutting down the unit, allowing the transaction or replacement, can co-ordinate arrangements for building the capacity of ultra-low emission coal-fired units. In 2020, the city's coal accounts for the proportion of total energy consumption control to 58.6% or less.

3, in-depth implementation of coal-fired boiler control. Increase the small coal-fired boilers (including coal-fired boilers and furnaces tea, operating the stove, grain storage and drying equipment, coal-fired facilities) elimination efforts. According to the principle of small demolition and Japan to promote clean energy use, developing the approach to co-ordinate the establishment and management of inventory ledger. Strengthen ecological environment, housing and urban construction, industry and information technology, market regulators linkage, strictly control new coal-fired boilers. 2018, 10 steam tons / hour (or 7 MW) coal-fired boilers and focus on the completion of the phase-out of county level and above all the urban area and old inefficient coal-fired boilers small tasks within the industrial park, small demolition boiler mission of 111; 2019, to phase out coal-fired boilers to further improve standards, expand the scope to promote the elimination of urban built-up area of ​​20 steam tons / hour (or 14 MW) and coal-fired boilers, in addition to special planning according to urban heating heating boilers other than essential to retain, urban built-up area 20 steam tons / hour (or 14 MW) coal-fired boilers to be eliminated and all.

4, the development of industrial furnaces governance special action. Development of industrial furnace remediation plan to carry out an intensive investigation, the establishment of various types of industrial furnaces inventory management. Increase the non-compliance of industrial furnaces out of efforts to speed up the elimination of small and medium gas furnace. Encourage industrial furnaces use electricity, natural gas and other clean energy or heat from the surrounding power plant. Key areas banned fired stove, the coal-fired cogeneration substantially eliminated heating pipe network coverage heated oven (furnace); out hearth diameter of 3 meters fuels gas furnace, a fixed bed to increase fertilizer industry intermittent coal gasifier reform efforts; focus on the use of gas furnace industrial park, they will not have to switch to natural conditions, should build a unified clean coal gas central principle; prohibition blended with high-sulfur petroleum coke. The industrial furnace governance as key tasks of environmental inspectors, who have not included in the list of industrial furnaces were included in the autumn-winter peak load shifting production program.

Measures food factory gas 8t seller industrial boiler lithuania fire prevention measures which have food factory gas boiler fire prevention measures which food factory gas boiler fire prevention have what? For food plants are some dry goods. If the improper use of the boiler, is likely to cause a fire. In this case, that will cause great losses. So, for food plants, it must be for measures to prevent fires do carefully. Otherwise, if indeed there is a fire, then the loss caused by the food factory is immeasurable. 1, fire prevention measures (1) when food factory gas boiler ignition before combustion, as in the gas boiler has been filled with combustible gas remaining, so before combustion, to be launched first delivery, induced draft fan forced ventilation 5-10 minutes, plenty of gas replacement in the furnace, the eradication of combustible gases in the furnace to boost the normal combustion, a combustion burner from scratch unsuccessful demand, must be ventilated before combustion to the hearth again, plenty eradicate combustible gas. When selecting manual burning, manual and commissioning is difficult to ensure accuracy, according to the rules of supervision regulation, gas boiler active protection device to device, including active combustion, flame protection, burning and automatically adjust the necessary proactive alerts protective equipment. (2) When the furnace temperature is low or when wetter, difficulties due to combustion, the need to take appropriate measures to preheat the furnace. (3) in the intake pipe in front of combustible gas nozzle, the device should the pressure gauge. (4) If the calm flame, the combustible gas is fed immediately discontinued, only for air, the ventilation, then the combustion operation. (5) To prevent the onset of bursting gas boiler during combustion, it is necessary to check before the gas pressure in the combustion in the intake pipe, when the pressure to meet the requirements, then the furnace was purged using a blower, eradication explosive mixture in the furnace. Should strictly abide by burning first combustion gas after opening the guidelines. 2, food factory fire prevention measures (1) prevent gas boiler work off the fire: combustible gas burner output is too large, the flame will disengage burner, too many episodes of incomplete combustion of the combustible gas, a lot of memory product in the furnace blast mixed gas, there is a risk of explosion at any time. Therefore, we should pay attention to fire off phenomenon, specific measures are: a, stable embodiment of the flame; B, to adjust the air-fuel ratio near the theoretical mixture ratio; C, artificially increased combustion speed; D, adhere to stable pressure of the combustible gas; E, reducing the discharge velocity of the fuel. (2) prevent tempering: flammable gas output is too small, the flame will be retracted into the combustor, the boiler operation and stable flame without flame. After the moment continuously into a combustible gas, the combustible gas reaches the limit blasting, blasting rattling. Prevent tempering phenomenon approach are: a, the minimum discharge rate increase; B, it is necessary that the fuel discharged from the nozzle velocity greater than the burning velocity, i.e. adhere to the furnace pressure (3) into the post-combustion process until a stable condition , the supervision to be good combustion conditions, pay attention to conditioning the combustion air flow, stable combustion pressure, a stable flame can burn. (4) to cut chimney smoke, the Mars and pollute the environment, flaming chimney should be comprehensive treatment, such as smoke and dust removal equipment and Mars quell equipment. (5) in normal operation, can not pay attention to cold and hot temperatures, to prevent the onset of bursting. 3, to prevent severe food shortage in gas-fired boiler plant boiler severe lack of water or dry out somethin 'somethin' is a kind of chemical, oil-producing boilers throughout the attack. Fireman to supervise closely the timing of the water level in the boiler operation time in Sheung Shui, the water level indicator to check whether a job is often normal, the sewage discharge dirt cleaning process.

Paper industry coverage is very wide, the user in the choice of a steam 8t seller industrial boiler lithuania, require a combination of local environmental policy as well as the actual operating cost analysis, select the appropriate boiler selection.

Many users will find when operating electric steam 8t seller industrial boiler lithuania, the boiler will not appear abnormal ring, the water flow is abnormal happens, but do not know where in the cause. In this paper, electric steam boiler in the water shortage, what would happen, expand and talk.