travelling grate steam boiler

It features multi-fuel pot is made of the holding furnace bottom is inclined to the back wall for holding furnace bottom, in order to obtain good combustion characteristics. This is not the kind of boiler for the gas pipeline, also want to be able to lower the cost of the normal operation of the boiler, then oil-fired boiler is a good choice. Oil-fired boiler is an important sign of progress now era, the purpose is to serve humanity well, according to further improve the people's needs. Oil-fired boiler is carried out in accordance with certain commercial standard boiler design, to a certain extent, guarantee the quality of the boiler, but also increase the boiler heat absorption intensity to some extent, then how should we use it?

14 ton travelling grate steam boiler application:

14 ton steam boiler not only can be using in textile plant boiler industry, but also have a high reputation in central heating , like boiler for hospital, chemical industry, food plant, paper mill etc on where using steam and hot water.

The party hot water boiler output fast enough to provide high efficiency, give us save a lot of fuel costs, and exhaust gas discharged tested in full compliance with environmental regulations on emissions of air pollutants in Henan Province. Fast boiler responsible attitude also left us with a deep impression, overhaul maintenance problems for a number of aspects of boiler operation and post, sent a very professional technical staff and our butt, fireman guide our people, for the quick sale of party, we are also very satisfied. --customer feedback

Industrial boilers and gas condensate natural gas hazard industrial boilers produce condensate water hazards 1, the corrosion of condensate water boiler heating surface of the main hazards to the natural gas industry is a corrosive effect on the boiler heating surface of the boiler. Condensate corrosion WNS rear of the boiler heating surface of the bottom of the tube focus, mainly iron oxide corrosion products. Condensate corrosion can cause intense side wall thinning, strength weakened. (1) condensation with the flue gas evolution corrosion, some CO2 is dissolved in the condensed water, CO2 generated in case of weak electrolyte H2O H2CO3, ionized hydrogen ions, so that a weak acid condensate, and another part of the nitrogen oxides and containing a very small amount of sulfur dioxide dissolved in the condensate, enhances the acidity of the condensate, the pH of the condensed water as in table 1 were lower than the position of the drum 4.3. iron hydrogen evolution corrosion can occur in the acidic solution, and the strong acid, the reaction The faster rate. (2) Since the oxygen etching gas during combustion boiler need to ensure a certain air ratio, combustion flue gas contains oxygen. When the steam condenses, some oxygen will be dissolved in the condensed water, causing corrosion of the metal heating surface of the oxygen. 2, when the cross-sectional area to reduce the flue gas flow type gas boiler industrial boilers operate at low load, the heated surface of the flue gas, the condensed water gathered in the smoke tube, the resulting corrosion products accumulate in the bottom of the tube, even clogging of the pipe part, thus reducing the flow area of ​​the flue gas, the flue gas resistance increases, and increase in power consumption of the blower. 3, the furnace temperature is lowered, damage to the burner within the examination of natural gas in industrial boilers, often find a certain amount of condensed water. We found condensate discharge tube boiler such severe congestion, resulting in condensed water in the lower furnace does not discharge, and refluxed for aggregation. When the boiler is started, the heat accumulated in the furnace absorbs the condensed water and evaporated fuel combustion, thereby reducing the furnace temperature. If the furnace condensate accumulated too much, and even dipped into the burner, causing damage to the burner. Suddenly turn off the boiler, the boiler does not start, because the burner too much condensation water immersion, affecting the safe operation of the boiler. 4. Effect of boiler condensate generated on the heat sealing material penetrates into the sealing material of the boiler insulation, the point of the arrow indicated gas tank gas boiler WNS industrial boilers. Sealing condensed water immersion insulation material for a long time, the insulation effect will be weakened or even physical damage, increased heat loss. Meanwhile, the condensed water will make the sealing material deformation aging, sealing capability weakened, leading to a certain amount of flue gas emissions, which not only be dangerous, can also cause a certain amount of heat loss.