Tel No. (+86) 371-55629010

small vertical type coal fired steam boiler

Factors that affect factors superheated steam temperature changes affect food factory superheated small vertical type coal fired steam boiler plant food temperature variation effects superheated steam boiler temperature variation food factory, 1, 2 changes, and the air volume ratio of 3 changes, burner fuel properties and 4, 6, 7, change the saturated steam temperature change and desuperheating water flow operation mode change in water temperature in the pulverizing system 5, the heating surface cleanliness variation boiler load variations. Change in fuel volatile carbon content, calorific value and the like: 1. Variations in the nature of the fuel. When the roughening coal, fuel combustion in the furnace a long time, the center of the flame increases, the steam temperature. When the fuel water is increased, the heat absorption of water evaporation furnace, the furnace temperature is lowered, the increase in humidity, but also increases the volume of the flue gas, the flue gas flow increases, reducing the superheater heat radiation, convection superheater heat absorption is increased. 2. And change the air volume ratio: when increasing the oxygen content of the furnace, the low temperature due to heat absorption of cold air, the furnace temperature is lowered, the furnace outlet temperature. At a total gas flow is constant, a change will also cause shifts air distribution steam temperature. When a low flow rate is insufficient, part of incomplete combustion of pulverized coal, the flame center is moved upward, the furnace exit gas temperature. 3, changing the operating mode of the burners and pulverizing system: operating system will result in an upper pulverizing the steam temperature is increased, the swing angle of the burner changes, the change in center of the flame, steam temperature changes.

Overview of 10 Ton Gas Fired Steam Boiler

10 ton gas fired steam boiler for sale in ZG Boiler is a “D” type double drums water tube boiler, and its furnace hearth is adopted with membrane water wall structure. The 10 ton gas fired steam boiler has a good fuel application, such as light oil, heavy oil, natural gas, liquefied gas, city coal gas and so on. And it has the following advantages: compact structure, small occupation area, good degree of flame; Good thermal insulation performance; With automatic burner, high combustion efficiency; Multiple protection function, safe and reliable operation; ISO9001-2008, IBR and ASME certifications.

Fire fighting methods inventory boiler in the boiler use, if a fire phenomenon, you know how to deal with it? Today, Xiao Bian teach you the recipe. When coal is poor or low load, it may be administered less number, to maintain a high pulverized coal concentration, but can not chipping operation or asymmetric operation. Load is less than 170MW, should remain A, B powder layer to stable operation, when any failure to a powder, should be administered stable combustion, the failure to the powder to be put into operation, combustion stability, and then exit the gun run . Adjustment of the amount of the low-load air supply, to maintain the oxygen 4-5%, and adjust the opening degree of the auxiliary windshield. If it is a bad case of fire, may be appropriate to increase the primary air temperature, wind speed reduces time, but not overshoot the spark plugs burned once or blocked ducts. When the job should be strictly periodic system and to reduce powder powder switching system, dust bunker normal position at least 2.5 meters, so that a stable working state bunker, at each adjusting shutter powder to powder, the powder as far as possible amount consistent and stable, no spark plugs to prevent dust and to dust gravity caused by combustion fluctuations. Should maintain acceptable fineness of pulverized coal, according to chemical analysis, after adjusting the test plate to open Classifier, coal is poor or low load, it may be appropriate to increase the fineness of pulverized coal, in order to facilitate combustion. Maintain normal milling system, powder separator shall not clogging the tertiary air pinkish large deterioration in combustion. Furnace can eliminate air leakage and air leakage milling system, all view of the fire without plugging holes, play Giocondo, etc. should be tightly closed. Value of the long should keep abreast of the situation of coal and coal quality fuel, combustion instability occurs when, such as when a fault powder, coal mutation, the differential signal changes drum is too large, the oil should immediately cast coal combustion stability and taking samples for analysis. High load, the premise of ensuring steam temperature, combustion can be appropriately adjusted to prevent the shift of the center of the flame, so that the furnace exit gas temperature rise, caused by coking. Operator adjusting the main steam temperature may be employed with positive pagoda wind run, the central flame stabilizer. Should be a bellows pressure control as a basis for wind speed, in time to observe the duct pressure and temperature, the premise of ensuring primary air duct is not blocked, a bellows pressure should not exceed 4000Pa.

Fangkuai Company has a fully-automatic PLC intelligent control system designed and developed by itself with complete intellectual property rights. It adopts a combination of mechatronic control equipment and a programmable logic controller (PLC). Take the advanced programmable logic controller (PLC) as the "central processing unit" of the control system. The control system is operated through the touch screen, which greatly improves the degree of automatic control and operation reliability of the boiler, and the operation is simpler and more intuitive.