Tel No. (+86) 371-55629010

Gas Steam Boiler Cheap Armenia

Gas steam boiler cheap armenia how gas consumption is calculated: gas consumption gas steam boiler how to calculate: there are a lot of users do not know how to calculate the gas consumption of gas steam boiler steam boiler gas before you buy, there are a lot of phone users consulted, this this problem has plagued some users, it decided to write it again this morning article on "how gas consumption gas steam boiler computing", following on from me explain to you about the principles of operation of the gas boiler gas consumption formulas and gas boiler. 1. First, we first look at the gas steam boiler operating principle: the pressure of the fuel through the gas line is controlled by the flow valve through the ignition burner Automatic combustion air, the heat emitted by the heating surface of the boiler sufficiently absorbed (three return) flue gas (carbon dioxide and water) into the atmosphere through the chimney. 2. Gas-fired steam boiler fuel consumption cost analysis (we have a 4-ton gas-fired boiler, for example) fuel light oil and gas projects Rated evaporation 4t / h2t / h thermal efficiency of 92% to 92% fuel heating value 8500Kal boiler / Nm310300Kal / Kg fuel consumption amount 300Nm3 / h24Kg / h auxiliary mechanical and electrical consumption 11KW · H11KW · H fuel Price yuan / Nm3 yuan / Kg fuel costs per hour yuan per hour RMB auxiliary mechanical and electrical consumption costs the first year cost of fuel (million, according to 350 days / annualized) in the auxiliary equipment costs (million yuan, according to 350 days / year basis) of the total cost (million, according to 350 days / year basis) (Note: at 12 hours per day)

The onset of winter, is located in Jilin Province Dongliao has entered the heating season. Recently, the Market Authority early planning, meticulous planning, to increase the safety supervision of the winter heating boiler, ensure the safe operation of heating boilers, curb the occurrence of all kinds of accidents, to protect people's safety, warm through the winter.

Market Authority set up a special investigation and remediation work organization boilers, special equipment to carry out self-examination from the security situation boiler heating units used to implement the main responsibility for the use of special equipment unit; simultaneous information collection boiler safety hazards, analyzing, improving risk control mechanism, proper risk monitoring, early warning and disposal of systematic risks and hazards should be reported promptly and truthfully; submit the initiative "special equipment unit security risk self-examination and self-change information tables to special equipment safety supervision organs ", and accept the supervision and inspection of the market, ensure that the boiler control risks effectively.

As of now, the council inspected the heating boiler unit 13, heating boilers and other special equipment to check 18 times, investigation and security risks 3 onwards, has been completely removed. The bureau said the next phase will further increase the safety and inspection of heating boilers, heating boiler unit supervise the implementation of the safety requirements, ensure that the heating boiler and other special equipment safe and stable operation. While strengthening the duty to timely and properly handle emergencies, a comprehensive good winter heating special equipment emergency security work.

Boiler fire phenomenon, how to do 1, furnace pressure fluctuations or to limit and alarm. 2, no flame detector flame, flame flameless television display. 3, flue gas oxygen abnormal fluctuations. 4, steam pressure steam temperature dropped drastically. 5, furnace black, black smoke chimney. 6, the flue gas temperature is reduced. 7, MFT action, turbine trip, splitting the unit. Cause 1, the furnace combustion conditions organizations unreasonable, improper wind coal proportion. 2, the load is too low, unstable combustion conditions without oil combustion vote, or vote, although oil but not good combustion results. 3, cast oil, poor quality oil, oil spray gun is bad, low oil pressure, oil system failure. 4, poor coal quality, coal is too rough, the water is too large pulverized coal combustion adjustment is not timely. 5, the primary air temperature, air pressure is too low. 6, boiler MFT protection action. 7, a large area of ​​the furnace coke collapse, smashing off the flame. 8, severe water wall pipe explosion will blow out the flame. 9, all coal-fired condition, mill pulverizing system failure caused most or all trips. 10, a part of auxiliary machinery such as a fan, blower, fan, air preheater tripped, causing unstable furnace combustion conditions. 11, sootblowing properly, resulting in a large number of normal operation of the furnace ash effects of fire inspection of the boiler. 12, bottom seal damage. Treatment 1, the boiler fire, MFT should be action, otherwise manual MFT. 2, normal inspection device linkage linkage MFT, confirm that all fuel cut. 3. quickly identify the cause, try to eliminate the boiler can be re-ignition, the recovery unit operation. 4, when the mill started again after the trip, the trip must be the primary air tube mill full purge. 5, the MFT operation, checks, Fan normal operation, automatic furnace vent. 6, the MFT movement, check all the secondary purge air damper position is set, the total air volume is automatically adjusted to 30 ~ 40% BMCR sufficiently purged air volume. 7, the MFT operation, when the turbine is in a state disk drive, the disk drive must continue until the normal turbine eccentricity, before re turn red. 8, if temporarily unable to identify or eliminate the cause, restart and could threaten personal safety equipment, non-start. 9, processing according to the corresponding predetermined remaining MFT.

Industrial electric steam boiler cheap armenias, electric, industrial steam boilers offer much quote how much? Although natural gas steam boiler is mainstream, but as many local companies still need electricity steam boiler. So, in industrial production, there are still many places need to use electric steam boilers that do not have a specific price of industrial enterprises to fast boiler consulting industrial electricity steam boiler. In this regard, the pre-sales engineer fast boiler after a detailed understanding of the needs of the industrial enterprises to provide current data capacity, there is the production of steam required tonnage, so, to be able to be used for the enterprise the tonnage of the most accurate accounting, for which data fast boiler pre-sales engineer is given the industrial enterprises 2t electric steam boiler on it. The current price of the fast boiler models at around 180,000.