Tel No. (+86) 371-55629010

98 efficiency electric hot water boiler

Fangkuai Boiler has more than 200 after-sales service outlets across the country. Each after-sales service outlet is equipped with a professional 98 efficiency electric hot water boiler technical engineer, providing 24-hour emergency repair services, and has sufficient spare parts and wearing parts all year round, convenient. Customers change in time.

1 ton gas 98 efficiency electric hot water boiler running on natural gas cost calculation users in the purchase of boiler equipment, in addition to considering the quality and price of the boiler, operating costs are also most concerned about. As a large industrial boilers special equipment, operating costs after start-up is not low. Today, small series to calculate the running costs of natural gas boiler, to help you better understand the gas boiler. On the whole, operating costs including natural gas boiler: fuel costs, utilities, labor costs, maintenance costs. Run 1 ton gas steam boiler 1 hour example to calculate the cost of running the boiler. 1, the cost of gas, 1 tons of gas steam boiler steam rated the amount of 1 ton / hour, different in different parts of the integrated natural gas quality and other factors, natural gas consumption in the 70-80 cubic meters / hour, according to our understanding, now on the market of natural gas the price of 3.5 yuan / cubic calculated (prices slightly floating), gas consumption is calculated according to 75 cubic meters. Gas Cost: 1 × 75 × 3.5 = 262.5 / hour 2, the cost of water, gas steam boiler 1 tons an hour to convert 1 ton 1 ton of steam into the water, because the middle of demineralized water and sewage water treatment needs, 1 ton of normal use of the steam boiler takes about 1.1 tons of water, according to our understanding, the market price is now floating around 3 yuan / ton. The cost of water: 1.1 × 3 = 3.3 yuan / hour 3, the cost of electricity, the main fuel gas steam boiler 1 ton electric burner position and pumps, other mostly weak. Burner using power 1.5KW, use the pump power of 1.4KW, other weak power use of about 1KW. During normal use of the boiler, electrical power is 0.65 times the full load power, calculate the total electric power (1.5KW + 1.4KW + 1KW) × 0.65 = 2.535KW. The electricity is $ 1 / calculation. Electricity costs: 2.535 × 1 = 2.535 / hour 4, labor costs, fast boiler into gas boiler market is the intelligent automatic high boiler plant, only coal fireman who patrol back and forth without the need to manually add fuel high intensity work. Fireman who according to 3000 yuan / month wage, working 12 hours a day, in two shifts. Labor costs: 3000 × 2 times / 30 days / 24 h = 8.33 yuan / 5 hours, gas boilers, and maintenance costs of model SZS fast WNS square type gas boiler in the factory after the quenching treatment and a full range of testing, failure rate Very low, response, post-boiler maintenance costs are reduced. If it is a gas station one ton steam boiler, the maintenance cost is about 2000 a year on it. According to 365 days a year, eight hours a day of computing time, the boiler operation cost per hour is: 2000/365/8 = 0.68 yuan. Combining these five aspects of the cost of inputs, it can be summed up 1 ton operating cost per hour of gas boilers: 262.5 yuan / hour + 3.3 yuan / hour +2.535 yuan / hour +8.33 yuan / hour +0.68 yuan / hour = 277.345 yuan / hour . In addition Xiao Bian also like to remind you that the above calculations are based on the cost of using boiler operating at full capacity, but due to the use of the boiler boiler enterprises have different needs, it may not be fixed to keep running at full capacity. Therefore, some of the actual running costs of the boiler than it is now calculated 277.345 yuan low. If you have more questions about natural gas boiler in the running cost, please direct online consultation fast boiler for more details boiler equipment!

First, before regularly shutting down 98 efficiency electric hot water boilers and inspecting electric furnaces, the following three aspects of preparation should be done: The main contents are as follows: (1) consult the technical file of boiler retrofit electric furnace registration and understand the use of boiler retrofit electric furnace. In order to make the boiler reform electric furnace inside and outside inspection, the general need to know: boiler transformation electric furnace design, manufacturing, installation situation; boiler transformation electric furnace transformation situation; boiler transformation electric furnace operation history and use situation; Boiler retrofit electric furnace water treatment, boiler rules and regulations implementation, and so on.

2) the preparation for stopping the furnace before inspection. First, according to the maintenance schedule, the furnace shutdown date is arranged, and then the boiler revamping electric furnace is shut down according to the normal shut-down procedure, so that the furnace is slowly frustrated. The cooling method can be adopted by injecting gas to dissipate the sinking water, replacing the furnace water for cooling, and cooling by ventilation in the in-line furnace. When the temperature of the furnace water drops to 70 ℃ 80 ℃, the water can be discharged. Open all the doors. When opening the door hole, prevent warm water, steam suddenly spurts out to burn people. The steam, feed water and sewage pipes in the furnace are separated from the corresponding pipes in the boiler revamping furnace in operation. The baffle used for partition should be strong enough to avoid being bulged out by high pressure media. Break position Clear instructions should be given. The flue which is connected with other boiler revamping electric furnaces should also be reliably separated. In addition, it is necessary to remove the soot and scale on the heating surface of the boiler retrofit electric furnace.

3) preparation of inspection tools and lighting. In order to ensure smooth inspection work, inspectors should prepare the necessary instruments, tools, gauges and safe and reliable lighting.

The importance of water supply equipment Gas supply equipment continuous steam 98 efficiency electric hot water boiler steam boiler 1. The effect of gas boiler room in the boiler room of the water supply equipment is a very important device all the boiler system. It is responsible for steam boiler feed "raw material", it can be a need to use the normal production of steam. During the operation of the boiler, the water supply equipment necessary to support synchronous operation, in order to continue to supply feed water to the boiler, the boiler can get enough water supply in normal operation safely. 2. Classification feedwater steam boiler steam boiler water supply equipment, there are two methods of water supply, water supply and electric steam-driven water supply categories. Steam-driven water supply equipment mainly refers to water vapor and reciprocating pumps, spare typically acts on the boiler water supply equipment. Another method of comparison used is an electric water supply through an electric centrifugal pump for water supply and vortex. Steam boiler during operation usually needs water supply equipment with active control function, the choice of the water level drops to a certain position to take the initiative to open pump water to the boiler, the water to a certain position but also take the initiative to stop the pump "bit" type conditioning. Boiler feed water can also be (a) water conditioning or heating condition circulated. Therefore, the gas boiler are usually equipped with an electric centrifugal or vortex pump, not equipped with the movable steam supply equipment.