Tel No. (+86) 371-55629010

Double drum coal fired steam boiler for food industry

Advancing the ignition point of coal, the temperature of the furnace to improve the ash carbon content decreased. Smoke swirling mix and strengthen the separation of coke particles in the flue gas, so that it falls on the fire bed and the new layer further fuel burn. Flue gas also strong swirl in the flue gas CO, H2, CH4 and other combustible combustion gases, thereby improving the thermal efficiency of the boiler is more than 4%. But also improve the boiler output to meet the needs of the production of steam, reducing environmental pollution, expanding the scope to adapt varieties of coal. 2. The air supply and reasonable regulation. In Grate, vibration stove, oven and forth, depending on the characteristics of the combustion process, reasonable air, to promote combustion furnace is very important. As the chain furnace, with grate the fuel is kept in motion, occur sequentially ignition, combustion, burn various stages. Along the longitudinal direction of the combustion grate stages, the partition, the amount of air required in the grate longitudinal direction is different. In the preheating zone of the head and the tail of burnout grate stage, small air requirement in the middle stage of combustion grate, the air amount required.

The method of adjusting the temperature of the superheated steam heating stove have? The method of adjusting the temperature of the superheated steam heating stove have? DC boiler steam temperature is mainly adjusted by adjusting the quantity of fuel to water. In actual operation, because the efficiency of boiler feed water and fuel heat enthalpy (depends on the water temperature) and the like will change, so the actual boiler operation to ensure the water-fuel ratio of the exact value is not easy. Coal-fired furnace will fluctuate because of the amount of coal and the amount of fuel due to the steam temperature. So, except DC boiler fuel to water ratio as the coarse adjustment means, but also must be used as a method of spray desuperheater means of fine-tuning adjustment. There is also some boiler flue gas recirculation, dampers and methods of the swing center of the flame as an auxiliary adjusting device.

Henan combustion control and adjust fast boiler boiler company to introduce small series with the boiler combustion control and adjustment. 1 double drum coal fired steam boiler for food industry combustion process is the basis of all the work process of the boiler, from the safe operation of the economy, environmental protection point of view, how to properly regulate the burning furnace, saving coal consumption is the responsibility of each fireman. 2 hot water boiler combustion conditions primarily by uniformly supplying the fuel, and air distribution adjusting reasonable combustion equipment is achieved, the coordination of the three, to ensure stable combustion conditions, economy, safety. When coal and boiler load changes, will need to adjust the amount of coal feed and the amount of the wind, in order to obtain a normal combustion conditions. Indicator 3.1 normal combustion conditions 4.8.3 normal combustion means: timely fire burning strong, ash burnout. Specific requirements:. A fuel inlet from the anterior arch 0.1-0.15 m fire, gray ash ex chain at the 0.3-0.4 m burnout. B. fire bed smooth, dense and uniform flame, without flame or blown partial blackening phenomenon. C. Flame intermediate white light, two dark, the fire grate bed length representing more than 3/4 of the effective length. D. pale gray smoke or nearly colorless. In order to achieve good combustion conditions, must maintain a high furnace temperature, the temperature of the upper layer is generally burner combustion layer preferably 1100-1300 deg.] C, may be determined according to the color of the flame. Furnace temperature and flame color relationship in the following table. The outlet temperature of the furnace can also be used to determine, 29MW boiler design furnace outlet temperature of 1017 ℃, 58MW of 998 ℃. 3.3 In the case of normal combustion, the oxygen content in the flue gas is constant, the oximeter, fireman can understand the situation of excess air in the furnace, the furnace excess air is generally mechanical 1.2-1.4%, of excess air and oxygen table below. Ash 3.4 combustibles content is an important sign of good and bad conditions of the boiler combustion, which fuel, combustion equipment, and operations are closely linked, general mechanical furnace ash carbon content should be less than 10%. 3.5 water boiler operation should ensure that in the case of no condensation of the tail to minimize exhaust gas temperature, exhaust gas temperature is controlled at 110-160 ℃. Adjusting and controlling the amount of coal to a fireman who adapt to changes in load, the supply must be based on different types of coal and the various stages of the heating season, the weather trend, the thickness of the seam is determined, the general control of the thickness of 80-100mm low load, medium load control in 100-120mm, high load control in 120-160mm. 2 fireman in specifying a seam thickness, to be due to the furnace, because coal should comprehensive analysis, on balance, for the ash content, water large, large particles, high ash melting point of the coal, generally the appropriate tone thick seam, opposite seam is to tune thin. Small particles of coal or pulverized coal and a low ash melting point of the plurality coal i.e. strong bonding to a thin coal seam. Generally the 3 or the boiler when the load change is not too large, the method should not be used to adjust the thickness of the seam. Because coal seam thickness adjustment can not be effective immediately adjust the load only when a large load changes, and long-term stable operation of the boiler in the new load considering regulating coal seam thickness. 4 seam thickness can be achieved by adjusting the height of the coal and layered coal hopper shutter speed of the drum. Shutter elevation coal, coal may be added into the same hierarchical improved coal hopper drum speed may be increased into the amount of coal seam in order to obtain a proper height, the height of the shutter must coal, coal hopper drum speed stratified and chain speed adjustment of the three. Given the limited level editor, inevitable errors and inadequacies, please correct me! Henan fast Boiler Company is committed to a wide variety of gas-fired boiler, steam boiler manufacturing, product quality, reasonable prices and widespread customer industry praise, if you have any needs, please contact us!

Shandong Mining Group in the six months after the boiler use, users submit a report to our company, our company started in 2017 using WDR0.5-0.8-Ⅱ electric fast Boiler Co., Ltd. of heating double drum coal fired steam boiler for food industry. Large output, stable and reliable, high degree of automation, simple operation, do especially in terms of security is in place. After-sales service is very timely response to our technical consulting reply quickly and accurately. Whether it is party party products or fast fast service. My company is very satisfied. --customer feedback