10t Boiler Brand Cheap Ukraine

Currently the design of water tube 10t boiler brand cheap ukraine configuration, there are four, namely, D, A-type, O-type and angle tube. Four structural types of the most popular type D, since D-type arrangement is more flexible in terms of superheater and economizer, the boiler can save a lot of building area.

Gas 10t boiler brand cheap ukraine full of water occurs, the occurrence of how to deal with gas boiler filled water, a high level alarm will sound an alarm level signal, beginning with the water vapor, decreased steam quality, increased salinity, superheated steam temperature drops. Severe full of water, or even furnace water into the steam line, steam line caused water hammer occurs, resulting in a serious impact to the boiler. When full of water for the boiler this situation occurs, fast Boiler summarize the following knowledge points, for your reference. First, the phenomenon when the boiler is full of water 1, the water level is not visible or not, a high level alarm; 2, steam temperature decreases, main steam isolation valves and the turbine inlet valves visible white steam; 3, turbine or steam pipes water hammer; 4, the normal water flow is not greater than the steam flow. Second, a full water Boiler feed water is automatically jump manually, resulting in abnormal increase of water supply; 2, or drum set on the safety valve steam header, resulting in up water or with water; 3, ultra-evaporation boiler load more, happens priming. Third, the full boiler water treatment 1, boiler steam pressure and water pressure to normal, while the drum water level rises, exceeds + 50mm, should take the following measures: wash drum were compared with the two water gauge to check their instructions are correct. Water supply from the automatic to manual adjustment, and shut off the manual door small total feedwater adjusted to reduce the amount of water to the door. 2, if After the treatment, the inner drum water level is still rising, exceeds + 75mm, the following measures should be: open the door for emergency drain drum should be put to the normal water level water level shut down immediately. The steam temperature condition, turn down or turn off desuperheating water door, door open and main steam superheater tubes hydrophobic hydrophobic gate. 3, when the boiler full of treated water drum water level continues to rise, and exceeded the upper drum level table when the water level is visible, the need for emergency shutdown, as soon as possible with the main pipe splitting, immediately stop the water, recycled to open doors, to strengthen boiler drain, and note the emergence of drum water level gauge upper water level, the water level to be put to the normal level after closing. After the normal Standby furnace, obtain professional fireman who consent, it may furnace stoked operation. 4, such as the water level in the steam drum water level tables invisible, not in time, should take the following measures: wash drum were compared with the two water gauge, check if the indication is correct. Full drum water level tables turn on the water door, turn on the water and then slowly close its doors, as there is water in the water table appears, and water levels continue to rise full of tables full of water and has not been proven boiler water level gauge steam over the side of the tube, press the emergency shutdown process. Open the door turn on the water table level, and slow to close its doors after the turn on the water, the water level in the water table invisible. To prove a serious full of water, soda and then close the door, turn on the water to open the door, the water level of the water table memory after the release to do, turn on the water shut the door immediately. Ajar quickly and valve inner water table level occurs, and filled with water, before this time has exceeded the determination level of the steam drum level side through the tube sheet, emergency shutdown should be treated as soon as possible and the manifold splitting. When the water level in the boiler accident occurs, it is difficult to judge if the water level should be shutdown immediately. After a boiler shutdown called water method called water, check the water level in the drum.

Whether steam 10t boiler brand cheap ukraine can be modified and return Type Description: steam boiler, which is more common and we can see a number of occasions in a kind of boiler, because of its wide range of applications. However, for now, we have reached the level of learning, is not comprehensive and specific, there are many omissions, so below, it may be added that, so we have to learn content, thus, can be shortened between the target distance. 1. installation inspection certificate on the steam boiler, usually a few years a check ah? This statement, in the steam boiler is not, because, when you install steam boilers Supervision, Inspection issued, not inspection certificate, but the installation inspection report boilers. Moreover, it is generally installed after the acceptance of the issue in the boiler does not require a check of a few years.

For a long time, the 10t boiler brand cheap ukraine and burner are attributed to two different sectors each R & D re-combination, but the overall performance of the gas boiler, there is a qualitative impact. Fang fast R & D team after two years, estimates adjusted 300 times, breaking the status quo burner and boiler production separate, optimized depth coupled combustion system and heat transfer system architecture, combined boiler and combustion system, combustion system and successfully developed the depth of the heat transfer system coupled "Euromonitor θ5", so that gas-fired boiler into a complete energy system, to achieve a qualitative leap. "Euromonitor θ5" additional air pre-heater, cold air through the heat exchange tubes and the body opening for the flue gas countercurrent heat exchanger, the exhaust gas temperature is lowered while saving fuel; using a condenser, economizer flue gas heat recovery, thermal efficiency of the boiler can be increased by 10%; the use of FGR flue Gas recycling technology and Ultraten wing technology, improve heat transfer efficiency, emissions of nitrogen oxides emissions standards in line with domestic cities.