Distributor Boiler Plant 2t Lithuania

Chinese wine culture has a long history, wine blend. In the process of making wine, almost all wine prices are inseparable from the brewing process steam, we can say the stability and quality of steam purity of the wine production plays a decisive role. Lefort Wine has been committed to producing high-quality wine products, December 2016 No. 1, Lefort wine and I signed a one 4 tons of steam condensing steam distributor boiler plant 2t lithuanias, the company continues to provide high-quality wine work steam.

4 tph WNS series gas-fired fire tube distributor boiler plant 2t lithuania project for NongFu SpringSteam boilers are typically indispensable pieces of equipment in the production, providing enough steam for filtration, sterilization, aseptic filling and other processes. Nongfu Spring is one of China’s leading bottled water supplier, producing natural drinking waters, vegetable and fruit juices, functional beverages and other natural soft drinks. Nowadays, large scale production has been carried out in eight high-quality water sources. Nongfu Spring has always worked hard to be conscientious in taking care of the environment. This time, they decided to order several gas-fired boilers for green development. ZOZEN is preferred by Nongfu Spring by their rich experience and systematic solutions, helping provide two sets of 4 tph WNS series gas-fired fire tube boilers. Large corrugated furnace is adopted by these boilers for fuels to be fully burned and works with thread smoke tube, which makes thermal efficiency reach above 98%. Furthermore, ultra-low NOx emissions are able to be realized. Fully automatic safe operation can help save the running cost.

Misunderstandings in cleaning of condensing distributor boiler plant 2t lithuanias and their improvement measures

During the manufacture, transportation and installation of the condensing boiler directly supplied by the new factory, the inner wall of the condensing boiler is concentrated with oxide or other dirt, which causes the condensing boiler to be corroded by the hot surface during its initial operation. Therefore, a series of measures should be taken to ensure the cleanliness of the condensing boiler when it is installed and ready to run. So in the process of consumer cleaning, what mistakes will be misplaced, and how to use it correctly?

1. there is no chemical analysis in the process of chemical cleaning: chemical cleaning is a very rigorous process. But if the chemical cleaning is not complete, some of the dirt has not been completely cleaned; and if the cleaning time is too long, Wash phenomenon will occur; cleaning effect is not good, secondary cleaning will waste raw materials, and delay time. The phenomenon of excessive washing will aggravate the corrosion of condensing boiler, cause the metal bearing capacity of condensing boiler to decrease, and affect the normal operation of condensing boiler. The improvement measures are: must do the chemical analysis detection in the chemical cleaning process, every ten minutes to test the acidity, the total iron ion concentration, the PH value. When the two analytical data are close, the chemical cleaning reaches the end point, neutralizing the acid solution to the neutral and then discharging.

2. no passivation after chemical cleaning: passivation process is actually a clean condensation boiler body surface and passivation agent re-reaction process. Because the control point of passivation is more strict, if the control point is not well controlled, the passivation will fail, and if the pickling is finished, only simple neutralization will be carried out, and the cleaning will end, which makes the surface of the cleaned condensing boiler easy to produce secondary floating rust. The scale-inhibiting ability of condensing boiler is reduced, which makes it easy to rust. The improvement measure is to rinse and passivate the condensing boiler after pickling. Because the passivation requirement is relatively strict, the concentration of total iron ions must be strictly controlled in the rinsing process. Rinse After finishing, the pH value should be adjusted to strong alkalinity immediately after the iron ion is detected, and the passivation agent should be added to passivate the temperature.

Precautions

1, the general position of the explosion vent means in the top wall or the steam outlet of the boiler furnace furnace furnace side of the fuel gas flue.

2, explosion-proof doors should be installed in place without the threat of operator safety, and a pressure relief guide tube, it shall not be stored near inflammable and explosive materials, highly preferably not less than 2 meters.