Tel No. (+86) 371-55629010

biomass 5000 kg steam boiler

Wood waste biomass 5000 kg steam boiler is a type biomass fired steam boiler which mainly takes wood waste as its fuels. In Zimbabwe, there are over 70,000 tons wood waste generated from the timber industry each year. In the long-term, this figure is projected to double by 2015. At most large timber mills, only a small fraction (~10%) of wood waste is currently consumed in process steam boilers for lumber drying kilns, while the vast majority is burned in the open air or dumped. Therefore, there is large potential to build power plants and wood waste steam boiler is good choice which is not only energy-saving but also eco-friendly.

Use small electric biomass 5000 kg steam boiler steam boiler electric steam boiler steam boiler using a small electric steam boiler electric steam boiler manufacturer boiler Class A: Yongxing boiler - designated national, A-level qualifications, professional supplier of electric steam boilers, gas boilers, coal-fired steam boilers, biomass steam boiler. Kinds of environmental protection steam boiler. Factory Scope of supply: all regions of the country and Southeast Asia. Boiler types: electric boilers, electric steam boilers. Supply and installation of: direct factory boiler, installation, commissioning and after-sales service can directly call or message advice. What are the advantages of small electric steam boilers that? One. When the electric steam boiler leak hazard, the boiler controller automatically cut off power supply to avoid electrical shock. 2. Automatic water supply function: When the water in the boiler is lower than the safety level, the automatic stop heating the heating tube to prevent damage caused by dry combustion and ignites the indicator water; III. Typically, cable is connected between the ground and well grounded. When the boiler steam pressure exceeds a set limit pressure relief valve start and release the steam to reduce the pressure. four. Overcurrent protection: When the boiler overload (high pressure), earth leakage circuit breaker is automatically disconnected. 5. Power Protection: use of advanced electronic circuit detects over-voltage fault condition, undervoltage, reliable power failure protection. 6. The vapor pressure of the small electric steam boiler with a variety of specifications, the power of the select electric steam boiler; 7. Electric steam boiler is electric energy, no noise, no pollution, no emissions of environmental protection products. 8. A steam boiler is heated by a small electric power control, ease of installation and matching, large boiler (500Kg) of the furnace is prevented and the control electronics electronic control portion of the furnace affected. High temperatures, to ensure stable operation. 9. The boiler temperature by automatic control cabinet. Insulation and electric heating control technology, the thermal efficiency of 97%. ten. Boiler advanced electrical controller having a computer boiler reliable performance, high degree of automation, easy operation. Using the electrical components to ensure high quality of production. Life products. Small electric heating steam boiler 1. The boiler performance characteristics of the boiler furnace using steel pressure vessel, the longitudinal and circumferential weld furnace automatic welding, and X-ray detection. Small furnace and electrical integration, easy installation. 2. The JB / 2379-93 standards and technical requirements of the metal pipe heating element, a low load heating surface of the heating element. Thick stainless steel high electric wire outer tube, the inner tube is filled with the high purity magnesium oxide, electrically heated tubes and long service life. Each heating element has a flange, simple structure, high mechanical strength, safety and reliability, can be replaced. 3. Compact, scientific and rational design, advanced manufacturing technology enables the boiler space is small, easy to transport, saving the use of space. four. Intelligent automatic control technology, without duty. Flexible and can be set to manual or automatic mode. 5. Set the boiler automatic operation time period, day provided several different duty cycles, the boiler is heated in each group sharing start automatically cut off the heating cycle and into the group. Contacting all use the same frequency and time, improve the life of the device. control. Seven. Full protection, leakage protection, water protection, ground fault protection, steam overvoltage protection, overcurrent protection, power protection, the boiler automatic protection, security. Full home. 8. No noise, no pollution, high thermal efficiency. High quality and efficient boiler heat insulation materials, low heat dissipation, energy saving. 9. Boiler packaging design using well-known color plate, elegant appearance, easy to rust. Small electric steam boiler - Boiler power plant with procurement requirements.

Shunde main business of special sea oil production and processing, etc., in the course of special oil refining, a large amount of steam required for oil and gas extraction, distillation and extraction technology and other aspects, therefore, the boiler is supplied special sea oil processing technology company Shunde indispensable less equipment. As environmental policy progresses, the chemical industry as more polluting industries are highly valued the various departments of quality supervision, sea Shunde companies to follow the development of the State Environmental Protection pace, choose clean the boiler industry-leading fast Boiler cooperation with the parties by quickly assess the specific needs on-site estimates and sea Shunde, to provide a SZS series of 25 tons of steam water tube biomass 5000 kg steam boiler (SZS25-2.0-YQ).

The solid fuel fired and biomass fired boilers are mainly used in hotel, hospital, university, central heating, refineries, utilities, petrochemical, chemical, paper and pulp, steel and iron, food processing, power station, and other major processing industries. Solid fuel boiler is chain grate type boiler burning coal, biomass or mix-firing both. It adopts membrane water wall, with economizer in the rear of boiler. High combustion efficiency, energy saving and low emission. Three-pass tube design incorporating a wet back turnaround that eliminates the need for rear door refractory. Larger steam disengagement area providing high quality steam, larger steam storage capability for quicker response to sudden steam demand. Equipped with PLC-based control system to realize automatic operating in start-up, standby and shutdown control Designed, constructed and stamped in accordance with the requirements of the American Society of Mechanical Engineers.