Tel No. (+86) 371-55629010

coal fired steam boiler for sale price

Henan combustion control and adjust fast boiler boiler company to introduce small series with the boiler combustion control and adjustment. 1 coal fired steam boiler for sale price combustion process is the basis of all the work process of the boiler, from the safe operation of the economy, environmental protection point of view, how to properly regulate the burning furnace, saving coal consumption is the responsibility of each fireman. 2 hot water boiler combustion conditions primarily by uniformly supplying the fuel, and air distribution adjusting reasonable combustion equipment is achieved, the coordination of the three, to ensure stable combustion conditions, economy, safety. When coal and boiler load changes, will need to adjust the amount of coal feed and the amount of the wind, in order to obtain a normal combustion conditions. Indicator 3.1 normal combustion conditions 4.8.3 normal combustion means: timely fire burning strong, ash burnout. Specific requirements:. A fuel inlet from the anterior arch 0.1-0.15 m fire, gray ash ex chain at the 0.3-0.4 m burnout. B. fire bed smooth, dense and uniform flame, without flame or blown partial blackening phenomenon. C. Flame intermediate white light, two dark, the fire grate bed length representing more than 3/4 of the effective length. D. pale gray smoke or nearly colorless. In order to achieve good combustion conditions, must maintain a high furnace temperature, the temperature of the upper layer is generally burner combustion layer preferably 1100-1300 deg.] C, may be determined according to the color of the flame. Furnace temperature and flame color relationship in the following table. The outlet temperature of the furnace can also be used to determine, 29MW boiler design furnace outlet temperature of 1017 ℃, 58MW of 998 ℃. 3.3 In the case of normal combustion, the oxygen content in the flue gas is constant, the oximeter, fireman can understand the situation of excess air in the furnace, the furnace excess air is generally mechanical 1.2-1.4%, of excess air and oxygen table below. Ash 3.4 combustibles content is an important sign of good and bad conditions of the boiler combustion, which fuel, combustion equipment, and operations are closely linked, general mechanical furnace ash carbon content should be less than 10%. 3.5 water boiler operation should ensure that in the case of no condensation of the tail to minimize exhaust gas temperature, exhaust gas temperature is controlled at 110-160 ℃. Adjusting and controlling the amount of coal to a fireman who adapt to changes in load, the supply must be based on different types of coal and the various stages of the heating season, the weather trend, the thickness of the seam is determined, the general control of the thickness of 80-100mm low load, medium load control in 100-120mm, high load control in 120-160mm. 2 fireman in specifying a seam thickness, to be due to the furnace, because coal should comprehensive analysis, on balance, for the ash content, water large, large particles, high ash melting point of the coal, generally the appropriate tone thick seam, opposite seam is to tune thin. Small particles of coal or pulverized coal and a low ash melting point of the plurality coal i.e. strong bonding to a thin coal seam. Generally the 3 or the boiler when the load change is not too large, the method should not be used to adjust the thickness of the seam. Because coal seam thickness adjustment can not be effective immediately adjust the load only when a large load changes, and long-term stable operation of the boiler in the new load considering regulating coal seam thickness. 4 seam thickness can be achieved by adjusting the height of the coal and layered coal hopper shutter speed of the drum. Shutter elevation coal, coal may be added into the same hierarchical improved coal hopper drum speed may be increased into the amount of coal seam in order to obtain a proper height, the height of the shutter must coal, coal hopper drum speed stratified and chain speed adjustment of the three. Given the limited level editor, inevitable errors and inadequacies, please correct me! Henan fast Boiler Company is committed to a wide variety of gas-fired boiler, steam boiler manufacturing, product quality, reasonable prices and widespread customer industry praise, if you have any needs, please contact us!

Wuhan Port District Social Welfare Institute (apartments for the elderly) is invested by the government pension services, with a total construction area of ​​38,000 square meters, 532 beds, mainly adopt destitute persons, social support on behalf of the elderly. Hope to provide welfare to the elderly year-round 24-hour hot water, the original boiler equipment can not meet this demand, therefore, require additional purchase orphanage hot water boiler. After much investigation, in cooperation with the welfare determined fast boiler, provides three integrally condensing gas hot water boiler (WNS1.4-1.0 / 95/70-Y.Q) by a fast boiler.

Vertical coal fired steam boiler for sale price introduce vertical steam boiler Products: vertical steam boiler, all kinds of domestic furnaces comprehensive technical improvements, absorb the international advanced technology and the introduction of the new generation of horizontal fuel (gas) boilers, the product has been designed applied for the patent, the boiler head boiler shell, boiler shell, U-rings, furnace, furnace head, transverse pipes, tubes cupola. Combustion boiler using conventional techniques, from the media into the door hole, in the upper combustion grate, the flue gas was washed repeatedly laterally staggered in the cross-pipe furnace, in the flue gas containing fine dust particles and carbon black during the rise , multilayered tube is blocked, reducing the speed of movement, again falls on the combustion grate, burn the fumes into the atmosphere through the chimney. Performance: the boiler furnace grate rests within an upper portion of the U-shaped scraps, the direct flame furnace, and flushing mounted within curved tube furnace; vertical bent tube boiler structural features are: furnace interior curved inner pipe, increase radiation heating area. However, due to large water-cooling degree furnace, the furnace temperature reduced accordingly, therefore, generally suitable for burning high quality coal. The increase in the furnace masonry bricks, to maintain a high temperature furnace burn less coal. Better water circulation, where the site has been washed flue gas cooling water, the whole structure, good elasticity. Features: use of double grate combustion section of the combustion chamber, heating up, fast boosting of unburnt gas through the secondary combustion, functions as combustion, smoke, dust effect. Bending the upper furnace tube arrangement convection heating region, disposed in the lower furnace grate tubes and radiation heating furnace area, structure of the furnace and the flue gas flow, reasonable layout, good heat transfer, the boiler reasonable design, simple structure operation, easy maintenance, small footprint, less investment in infrastructure, the company is one of small enterprises with steam, heating and other equipment ideal.

Henan run several areas, including Henan gas boiler gas boiler operation includes several aspects: daily monitoring and adjustment operations; accident treatment; start and stop; optimal operation mode and technology improvements. When the normal operation of the boiler, the daily operation of the monitoring and adjustment of the operating accounts for the major part. "Stable" is the key, pressure, temperature, water level, negative pressure, milling parameters, etc., remain stable conditions is an important guarantee for safe and economic operation. Briefly, the steady working primarily by "balancing" the means to obtain, for example, outside the furnace combustion conditions and load balance, the pressure is stable; to balance the amount of water and evaporation, is stable water level; primer with the supply air volume the amount of negative pressure equilibrium is stable, according to Henan gas boiler operation adjustment purposes, and in accordance with the purpose of regulating the boiler operation, to take the necessary means of regulation. Daily adjustment of the key - "steam pressure." Among the major parameters of Henan gas boiler, main steam pressure to maintain stability is the key which only the steam pressure is stable, the remaining parameters to stabilize. Unstable steam pressure, steam temperature, the water level will also change, so first of all start from the pressure adjustment. Vapor pressure is divided into an outer and an inner interference disturbance, our plant, i.e. outside the external disturbance load generally little change, so change in vapor pressure are changed within the furnace i.e. interference caused by operating conditions, so holding furnace combustion conditions the stability is the stability of the vapor pressure. If the combustion conditions change, such as wind than powder, coal calorific value and other factors change, a pressure change occurs, requires us to be adjusted, thereby changing into a stable state of the combustion furnace transient state conditions.