Tel No. (+86) 371-55629010

boiler accessories

Steam boiler accessories in Sheung Shui should pay attention to what you want to steam boiler steam boiler conduct a comprehensive inspection before ignition, Sheung Shui steam boiler things should note the following requirements: Requirements 1, the steam boiler water, boiler water quality if the place of use water hardness is too high should be supporting, supporting demineralized water hardness can reduce scaling in the boiler tubes, thereby increasing the life of the boiler to reduce operating costs. 2, Sheung Shui, when should slow to add water inside the steam boiler feed water temperature is not too high. 3, add water, not too much, as the temperature of the water will continue to increase expansion, resulting in waste. Generally, add water to the normal water level of the water line also is the middle line on it, now supporting the steam boiler above all intelligent devices in Sheung Shui, simply open the smart addition of water it can be had. 4, to put inside the boiler economizer and air inside the boiler duct excluded when water was added. 5, after the Sheung Shui to see whether the water level in the water level dropped, there may be drain valve not closed tightly reason, you should check the steam boiler population during the Sheung Shui, welding flanges, pipe is leaking phenomenon exists, if found leaking immediately stop adding water and appropriate treatment.

Tai Chi, Jiaozuo City, Jiaozuo City Sports Center is one of important sports infrastructure, a total area of ​​11.73 hectares, held several international events. With strict management in Henan Province for air emissions of pollutants, Jiaozuo City, also launched the governance of coal-fired boiler accessoriess, thermal power and other equipment. Jiaozuo Sports Center actively cooperate with municipal workers, took the lead from coal to gas activities, the serious pollution of the original extent of coal-fired boilers to replace gas boilers. Gas boiler cleaning binding understanding of the market, to achieve cooperation with the finalization fast boiler by providing a fast side 2.8MW integrally condensing gas hot water boiler (WNS2.8-1.0 / 95/70-YQ), it is used to Sports Center provides heating and hot water.

Diagnosis: case of an electric steam boiler accessories can occur when water vapor through the use of electric boilers electrical energy, which is converted into heat, and then the converted electric heating system of the boiler steam output having a certain thermal energy outwardly. Many users will find when operating electric steam boiler, the boiler will not appear abnormal ring, the water flow is abnormal happens, but do not know where in the cause. In this paper, electric steam boiler in the water shortage, what would happen, expand and talk. In general, when there are electric steam boiler explosion that, at the door began to steam out, it shows electric steam boiler water shortage is very serious and should be carried out immediately pay, or they may be dangerous. Mainly as electric steam boiler water level has been cut siren sounded the alarm sound level below the safety line. At this performance should let dry electric steam boilers stop running, and then the alarm sound off, then add the water in the electric steam boiler above the water line, electric steam boiler restart just fine. Electric steam boiler exhaust smoke temperature rises, then it should be because the pipeline rupture caused by electric steam boiler, the solution is to pipe water shortage caused by electric steam boilers quickly repaired, or to replace a new pipeline. Boiler water can be divided into two cases, one slight lack of water, one serious water shortages. When the water level in the water level below the specified minimum but can see or can not see the water level has instead of "water law called" waters, could see the water level, water shortages were classified as minor. As the water level is not visible, but still a serious lack of water when the water level not seen as "Water Act called" waters. Program called the water: first turn on the water faucet is turned on, turn off the steam cock, rinse water connecting pipe parts, then slowly turn on the water tap is closed, pay attention to whether the water into the inner man boiler water level gauge, this method is referred to as "called Water Act." The reason water; the loss of the water level control light; dereliction of duty fireman; water supply system failure, such as lack of water pressure, no water fill, water level indicator is incorrect and false water level; boiler blowdown valve may be caused by a leak caused by lax boiler water. Boiler water should be promptly find the cause and correct treatment, improper handling can cause serious accidents. Water treatment: The water level is just below the normal level. But still we see, you can restore the normal water level should be strengthened and rinse water level in Sheung Shui. Check the water supply, water and other systems, for damage and leakage and other problems, severe cases should be treated shutdown. When the use of "water law called" flushing water level and other treatment still do not see the water level, severe water shortages may occur accident, should immediately shutdown, quickly turn off, find out why. In this case, the operator should remain sober and avoid confusion, non-Sheung Shui to the boiler, eager to avoid the possibility of replenishment and cause serious explosion in the boiler drum water boiled.

Electric steam boiler accessories into electronic and mechanical two categories: electric boiler level controller is a central nervous system-controlled steam, into mechanical and electronic two categories. Electronic probe electrode level controllers by three different high and low control level (i.e., the difference in height level) so as to control the heating time of the water supply pump and the furnace heating system, working pressure is stable, broad range of applications .