Tel No. (+86) 371-55629010

1t gas fired Boiler

Chinese wine culture has a long history, wine blend. In the process of making wine, almost all wine prices are inseparable from the brewing process steam, we can say the stability and quality of steam purity of the wine production plays a decisive role. Lefort Wine has been committed to producing high-quality wine products, December 2016 No. 1, Lefort wine and I signed a one 4 tons of steam condensing steam 1t fired boilers, the company continues to provide high-quality wine work steam.

How to set the height of the 1t fired boiler chimney

The coal fired boiler can be divided into two kinds´╝Üvertical boiler and horizontal boiler. And the horizontal boiler is very economic because of its long flue gas flow, slow smoke discharge, high heating efficiency. So it is widely sued in the market. After buying a boiler, it is necessary for them to build a boiler room,in the installation the height of the chimney also need to pay attention. According to the ZG engineer, the chimney height should be accordance with the lowest height of GB13271-2001 stipulation. Only one chimney is allowed in a boiler room. The specific requirements was listed below:

1.When the boiler’s output capacity is more than 1t/h or 0.7MW, a permanent thief hatch and relevant facilities should be setted in compliance with the stipulations of measuring method for smoke and dust of boiler emission, and The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source.

2. The exit diameter of the chimney should be not lower than the largest load. The smoke flow should not be too fast. when the load of the coal fired boiler is at its lowest level, the velocity of the chimney exit should not lower than 2.5~3m/s.

3. If the chimney heat does not reach the height of the above stipulations, the maximum discharge concentration of the dust,sulfur dioxide, nitric dioxide should be carried out at 50% of the corresponding area and time emissions standard .

Selection and classification of fuel gas thermal control system fuel gas 1t fired boiler 1. The boiler classification thermal control system (1) electric system for an electric meter instrument cluster system consists of relays, time relays, the relay program composed of program control and interlock system; manufactured by electronic control and intelligent series or digital instruments, measuring instruments display, sound and light alarm monitoring instrumentation and control system and other components. Electric instrumentation system design experience mature, the price is cheap, but it is difficult to achieve system redundancy, remote data transmission, maintenance is more difficult, more difficult to implement advanced control methods. Electric meter system is mainly used for small boilers, but the electronic control Applications for closed-loop regulation of decreasing almost been replaced by intelligent multi-function instrument, the following sections mentioned electronic control just want to take advantage of familiar industry and the series combination of a widely used instrument that time to explain the principles of the control system configuration and (2) programmable control system programmable control system is the core of programmable logic controller (PLC). Programmable logic controllers are widely used in the initial control, since the 1990s has increased the ability of process control, the programmable logic controller in the field of process control applications more widely.

This standard at age requirement 1t fired boiler flue soot, sulfur dioxide and nitrogen oxides emission concentration maximum permissible emission limits, and the blackness. This standard applies to coal-fired capacity and intended use of the fuel and emissions of air pollutants manage outside gas boiler boiler, and construction project environment (65t / h) In addition to power generation boilers and pulverized coal is greater than a single output 45.5MW impact assessment, design, final acceptance and after the completion of the sewage management.