Tel No. (+86) 371-55629010

300Mpa Coal Fired Steam Boiler In Mongolia

Fuel oil combustion process differs from the process industry Industrial Combustion fuel oil-fired boilers for industrial oil fired boilers and industrial boilers, having a certain temperature and pressure injected into the furnace through the nozzle is atomized into fine droplets, and then absorbs heat in the furnace, vertical oil-fired boiler, surface gradually vaporized into oil, mixed with intake air in the furnace, form a combustible mixture. The combustible mixture continues endotherm temperature reached ignition ignition combustion. Fuel amount, air amount and the amount of the composite has a one to one relationship of steam, it is necessary according to the load amount of steam required to control the amount of fuel and air supply, but also by the wind furnace pressure control apparatus. Different oil-fired boiler with a different point of industrial coal-fired boilers point of industrial boiler fuel industry and industrial coal-fired boilers. PM2.5 pollution damage to the environment led some coal-fired boilers industrial boilers is facing new boiler renovation or change of situation, which makes oil-fired boiler to become the darling of the market. Oil-fired boiler with a coal-fired boiler in comparison with structurally quite different purposes, as follows: (1) injecting fuel into the boiler furnace through the burner, combustion chamber without using fire grate facilities; (2) Since the oil, gas did not produce combustion ash, it is no oil or gas boiler slag and slag outlet device; (3) injecting a gas or oil furnace materialized, if mixed with air or flame within a certain range, is easy to form an explosive gas, Thus fuel (gas) required automated combustion boiler system, comprising a flame monitoring, flame protection, explosion-proof safety; (4) Since the oil, gas calorific value is much larger than the calorific value of coal, so the thermal strength than fired furnace high multi-furnace, so relatively small and the capacity of the boiler with coal-fired boilers, compact, small footprint; combustion process (5) fuel (gas) is suspended in a boiler furnace, the furnace is provided so its before and after the arch, the furnace structure is very simple. Meter manufacturing, Supervision, Inspection and the main characteristics of biomass fuel boilers [] protection devices and control systems introduced a biomass fired boiler biomass fuel boilers are in strict accordance with "Steam Boiler Safety Supervision", JB / T10094-2002 "general industrial boilers technical conditions ", JB / T1619-2002" shell boiler body manufacturing technology, "execution, ensure long-term security and stability of the boilers. Body is a shell type three return all wet back downstream pyrotechnic pipe structure, large combustion flame in the combustion chamber a slight positive pressure, stretched stretch, combustion heat load is low, less NOx emissions of harmful substances. Waveform furnace and threaded pipe structure that improves the strength, but also to meet the needs of each portion of the thermal expansion. Master butt welds are connected, and by X-ray and ultrasonic nondestructive testing, to ensure the welding quality to meet national requirements. Boiler water volume and large air space, adaptable load capacity. Design reasonable pot, with water vapor to ensure that less than 4%, to meet user requirements for higher quality steam. Using the new insulation materials, light weight, low heat loss, good insulation properties. Water level alarm stainless steel rods as electrodes, an insulating material as polytetrafluoroethylene. Inserted from above, linked to pollution easy, reliable, and long service life. Before and after the smoke box is hinged, can easily open, repair and maintenance quick and easy maintenance. Adjusting the oxygen content (optional): The system can successfully monitor the oxygen content in the flue gas, and transfer the data to the real-time control systems, intelligent analysis by a computer, the automatic adjustment device stoichiometric combustion, it is in real-time good working shape, combustion efficiency is greatly improved, which can significantly reduce fuel consumption. Biomass fuel boiler operation timing of the protection device, the operation of the control system by the timer, the system automatically enters the work or off duty. The control system may be provided multiple sets of the timing period within 24 hours. Any period of time in a group of a plurality of sets of timing of the current time period, the system enters the working state. Work within the timing period, the status screen is displayed automatically. In the period of time in commuting to work outside the state. Each group comprises a turn-on time period (hour, minutes) and a closing time (hours, minutes) may be set or modified when the three control period, divided by the setting operation and the current time. The user can set different time different temperature ranges.

In the process of cooperation with Lulu, the company has maintained a serious and responsible attitude and enthusiasm, any after-sales problems in a timely manner to communicate and resolve site or through the network. Lulu's relevant person in charge to give us feedback, we buy fast boiler is not only fast because of strong party strength, but also because of the powerful party fast service, any improper operation can get our phone to remind party fast remote monitoring, this allows us to use very reassuring. --customer feedback

The heat loss of exhaust smoke is the largest of all kinds of heat loss in boiler. Generally, the heat loss of exhaust smoke is 6% of the heat fed into the furnace, and the heat loss of exhaust gas increases 0.5% when the temperature of exhaust gas increases by 12 ℃ and 15 ℃. So the exhaust temperature is one of the most important indicators of boiler operation. The following are several possible causes of increased flue gas temperature in the furnace: (1) slagging and ash accumulation on the heated surface. No matter it is the slag accumulation in the water-cooled wall of the furnace, or the ash deposition in the superheater, convection tube bundle, economizer and preheater, the thermal resistance of the flue gas measurement will increase, the cooling effect of the flue gas will become worse due to the deterioration of the heat transfer, and the exhaust temperature will rise. (2) excess air coefficient Big. Under normal conditions, the exhaust temperature increases with the increase of excess air coefficient at furnace outlet. After the increase of excess air coefficient, although the amount of smoke increased, the rate of smoke increased, and the convection heat increased, the increase of heat transfer was not as much as that of the increase of flue gas. It can be understood that after the increase of smoke speed, the flue gas leaves the heating surface without time to transfer heat to the working fluid. (3) the air leakage coefficient is too large. The flue gas leakage in the furnace and rear shaft of a negative pressure boiler is inevitable and the leakage coefficient allowed by a certain heating surface is specified. When the air leakage coefficient increases, the effect on the exhaust temperature is similar to that of the superheated air coefficient. And the air leaks away. The closer the furnace is, the greater the influence on the rise in exhaust temperature. (4) Water supply temperature. When the steam turbine load is too low or the high pressure heater is out of line, the feed water temperature of the boiler will be lowered. Generally speaking, if the fuel quantity is kept constant, the heat transfer temperature difference of the economizer decreases and the heat absorption of the economizer decreases when the feed water temperature is increased, which makes the exhaust temperature increase. (5) moisture in the fuel. The increase of moisture in the fuel increases the amount of smoke, thus increasing the exhaust temperature. (6) Boiler load. Although the boiler load increases proportionally, the amount of smoke, the amount of steam, the amount of water supplied, and the volume of air increase proportionally, however, the flue gas temperature at the furnace outlet increases proportionally. Increase, so that the exhaust temperature increased. After increasing the load, the outlet temperature of the furnace increases, the heat transfer temperature difference of the convection heating surface increases and the heat absorption increases. Therefore, the more the convection heating surface is, the less the influence of the boiler load on the exhaust gas temperature is. (7) fuel varieties. When the low calorific value gas is fired, the radiative heat transfer in the furnace decreases due to the decrease of furnace temperature, and the non-combustible components in low calorific value gas, mainly N _ 2, CO _ 2 and H _ 2O, increase the amount of flue gas, so the exhaust temperature increases. Although the excess air coefficient of furnace outlet is lower than that of coal burning, the ash content in the fuel oil is very low after the pulverized coal furnace is changed to burn oil, although the excess air coefficient at the furnace outlet is lower when burning oil. There is no larger ash particle in flue gas, and there is no cleaning effect of larger ash particle on the heating surface, and the convection heating surface is polluted more seriously. Therefore, combustion is not good, often smoke-emitting boiler smoke temperature rise. When there is a steel ball dust removal device at the tail, the exhaust temperature is slightly lower than that of burning coal because the tail is cleaner. (8) the operation mode of pulverizing system. For a closed pulverizing system with a silo, when the pulverizing system is in operation, as a part of the water in the fuel enters the furnace, the furnace temperature decreases and the flue gas increases, and the cold air leaking into the pulverizing system enters the furnace as a primary air during the operation of the pulverizing system. Reduction of air flow through air preheater To raise the exhaust temperature. On the contrary, when the pulverizing system is shut down, the exhaust temperature decreases.

Small 300mpa coal fired steam boiler in mongolias will be fully modernized popular in the market after the 1980s, China's economy has undergone rapid changes in boiler industry is more prominent, national boiler manufacturing companies increased by nearly 1/2, small steam boilers will be fully prevalent in the modern market, and It can be formed independent development of generation after generation of new products. Small steam boiler is the era of economic development indispensable commodity, what the future will bring, but is well worth study. Group mainly used for small industrial R & D and production of small steam boiler, as far as we know, much higher production of small steam boiler manufacturers of small steam boiler prices, leading to small industrial input costs are also high, so many customers stay away, we had to continue small traditional steam boilers. Small steam boilers will be fully popular us on this cost, has been doing research experiments, and finally developed a small steam boilers for small industrial production process used at the beginning of 2017, we produced a small overall structure of the steam boiler Unlike other steam boilers in the modern market , through our special processing technology, the structure of the entire boiler changes, the use of safer, lower operating costs, more cost savings for small industry owners. Small steam boilers will be fully prevalent in the modern market, the Group's how we analyze the energy industry Riding out the following four points:? First, in terms of environmental protection, small steam boiler burning material is primarily natural gas, natural gas is a now clean energy, without waste combustion, the exhaust gases, as compared to coal, oil and other energy sources have a safe, high calorific value, clean and other advantages. Small steam boilers will be fully prevalent in the modern market two small steam boiler from a safety point of view is generally aspirated pipeline, the use of gas pressure units pre-tuned, fuel combustion more fully, the boiler is stable. Third, the thermal efficiency perspective, a small part of a steam boiler steam boiler pressure, since the connection within the furnace condensing system, the exhaust gas temperature is less than 110 deg.] C, operating thermal efficiency of 93%. Fourth, the use of the economic point of view, since the small water capacity of less than 30 liters steam boiler, from cold start to 5 minutes to produce saturated steam, warm-up time is greatly reduced, saving energy. Automatic intelligent operation, no fireman guard, eliminating salary expenses. Small steam boilers will be fully prevalent in the modern market is not difficult to see that the future prospects for the development of small steam boiler is very broad, because it is a vertical, small, small footprint, easy installation, small steam boiler to replace the traditional small excellent product steam boiler.