Tel No. (+86) 371-55629010

1t Condensing Boiler Dealer Uzbekistan

Shandong Mining Group in the six months after the 1t condensing boiler dealer uzbekistan use, users submit a report to our company, our company started in 2017 using WDR0.5-0.8-Ⅱ electric fast Boiler Co., Ltd. of heating steam boiler. Large output, stable and reliable, high degree of automation, simple operation, do especially in terms of security is in place. After-sales service is very timely response to our technical consulting reply quickly and accurately. Whether it is party party products or fast fast service. My company is very satisfied. --customer feedback

How to operate a natural gas 1t condensing boiler dealer uzbekistan, the preparatory work before starting: 1. Check gas pressure is normal, pipeline valve leaks, valve switch is in place. 2, the test gas reliable alarm system is working properly, the fan can start pressing the test button 3, the system checks whether the normal demineralised water, to ensure that the water softener is operating, the normal water tank. 4, check the boiler, the switching valve is normal decontamination. 5, 6 deaerator normal operation, water softening equipment can operate normally. Demineralized water should meet the standard GB / 576, the normal water level inside the water softener, water pump trouble-free operation. Second, the boot 1, the total power of the switch cabinet, check all parts are normal, whether there is a fault signal. If no signal should take appropriate measures to check or repair, troubleshooting. 2, into the automatic cleaning burner ignition, partial load, full load operating state. 3, when up to a certain pressure, should be regularly sewage once, and check the water level in the furnace. Third, the operation of the inspections: 1, the boiler power is turned on, the monitoring operation of the boiler normal ignition, flame status check, check the operation member without abnormal noise. 2, patrol boiler heating conditions, the size of the converted fire control situation is normal. 3, inspection of gas pressure is normal and stable, the natural gas flow rate is within the normal range, to determine whether the filter is clogged. 4, patrol pump pressure is normal, any abnormal sound. Fourth, the accident shutdown 1, when found in the boiler body to produce abnormal phenomenon, the safety control device failure, emergency disconnect button should move to stop the boiler operation. 2, boiler feed water pump damage, mediation device failure, should move emergency disconnect button to stop the boiler operation. 3, when power problems should take fuels pressing the emergency disconnect button. 4, when a boiler or jeopardize the safety of the phenomenon should take urgent measures to shutdown five temporary power outages Note 1, quickly turn off the main steam valve to prevent dehydration drum 2, turn off the power switch and the gas valve 3, shut down the boiler continuous blowdown valve to prevent the presence of other failures boiler 4, oxygen gas in addition to closing the valve 5, the normal shutdown sequence, checking boiler fuel, gas, water shutdown valve meets the requirements VI Notes 1 insufficient gas, fast scheduling and gas get in touch, ask why clear the accident, and take feasible measures 2, 3 report to the higher authorities and leader, always observe the combustion flame is normal wheat yellow

The fuels burnt in the furnace and combustible gasses move into the fire tubes, travel through these tubes from rear to front of the 1t condensing boiler dealer uzbekistan drum and finally the gases come into the smoke box. The hot gasses in the tubes under water transfer heat to the water via the tube walls. Due to this heat energy steam bubbles are created and come upon the water surface. As the amount of steam is increased in that closed drum, steam pressure inside the drum increases which increase significantly the boiling temperature of the water and hence rate of production of steam is reduced. In this way a fire tube boiler controls its own pressure. In other words this is a self pressure controlled boiler.

Why condensing gas 1t condensing boiler dealer uzbekistan thermal efficiency can reach 108% of the high? Many users in understanding the fast boiler, will provide a number rather confused - thermal efficiency, faster production side of the boiler thermal efficiency Why can reach 108% of the high?