Tel No. (+86) 371-55629010

5 ton coal fired steam boiler in canada

The transformation of low nitrogen boiler should be noted that what matters for retrofitting low nitrogen boiler should be noted that what? Of nitrogen oxide emissions is large, complex sources, environmental problems caused by acid deposition, fine particles, ozone, nitrogen oxides and analysis of contamination status must be further strengthened. If you do not take further measures to reduce emissions, with the United States and the United States to speed up economic development, population growth and urbanization, nitrogen oxide emissions will continue to grow in China in the future. Based on current trends, by 2030, emissions will reach 35.4x106 tonnes, will inevitably cause serious environmental impacts. Therefore, we must effectively enhance the emission control of nitrogen oxides. From this we can see that low nitrogen boiler is imperative! A check device to check for low NOX combustion gas before commissioning is in place, the gas pipeline flow is clean, whether the valve is open. There is a burner pipe leaks, reasonable pipeline installation. Discharging vent pipe valve from the foregoing, to ensure that no mixing of the air duct, and the exhaust pipe should be connected to the outdoor. Second, stable combustion and combustion of homeostasis Remember, combustion adjustment is the basis for all of the low nitrogen burner adjustment, as long as guaranteed under any changes in operating conditions of combustion stability and combustion of dynamic equilibrium, to burn steam temperature influence is even greater. Since the steam temperature is a sign flue gas heat value balance between the steam and heat absorption, this can be maintained as long as the dynamic balance, steam temperature can be kept stable. Third, the level of flame boiler boiler central flame center is also an important factor in high impact low-temperature steam. In the high temperature steam operation, the amount of coal combustor exhaust can be reduced, the amount of the lower stage burner of coal may be increased, and vice versa. Running low nitrogen burners, it should also be noted effect of different combinations of temperature steam mill. Steam at a low temperature exhaust composition regulating a large margin, the combination of the high temperature exhaust temperature adjusting stage so small margin overheat. It should be strengthened and soot blowing air distribution according to the situation.

What is the principle of the boiler? No matter how much the tonnage, the boiler works basically the same. Role of the boiler fuel chemical energy is converted into thermal energy, heating and heat inside the pot with water to become superheated steam having a mass and a sufficient amount (steam temperature, steam pressure) of the steam turbine for use. Now the power plant boiler capacity, high parameters, technical complexity, high levels of mechanization and automation, the main fuel is coal, and coal prior to combustion of pulverized coal first made, and then into the boiler combustion heat release in the furnace. Broadly speaking, the work process is the main boiler fuel combustion, heat transfer, vaporization and heating of the water with the superheated steam and the like. The entire boiler boiler composed of two parts and auxiliary equipment. Boiler: boiler body is the main part of the boiler equipment, is composed of two parts, "pot" and "furnace" composition. "Pot" is the soda system which main task is to attract the heat receiving fuel discharged, the water is heated, evaporated and finally becomes superheated steam having certain parameters. It consists economizer, the drum, the downcomer, the header, water wall, superheater and reheater connecting pipes and other equipment and valves. 1) economizer. Vertically positioned rear of the boiler flue, the use of flue gas waste heat boiler feed water, reducing the exhaust gas temperature, increase boiler efficiency, fuel economy (2) drum. At the top of the boiler, it is a cylindrical pressure vessel, which is under water, the upper portion of the steam is that it accepts the economizer runoff, while the downcomer composed header, Wall water circulation circuit. Wall water absorbs heat generated in the soda mixture was collected in the drum, conveyed by the saturated steam to the superheater steam-water separator (3) downcomer. Water supply pipe water wall, the effect of which is introduced into the water in the steam drum to the lower header redistribution respective waterwall tubes. Dispersion in small diameter and the large diameter downcomers Downcomer two kinds. Small diameter tubular small diameter drops, the water cycle of negative (4) waterwall lower header. The main role of the header is a mass pooled or working fluid through the header to the header redistributed through other conduits. A water wall is thicker lower header tube closed at both ends, its role is connected to the downcomer and the water-cooled wall, so as to function together, mixing, redistribution effect working medium (5) water wall. At the furnace around its main task is to absorb radiant heat of the oven, to evaporate water, which is the main heating surface modern boilers, while protecting the furnace wall (6) superheater. Its role is to drum saturated steam into superheated steam on heating (7) having a predetermined temperature reheater. Its role is done in the steam turbine power section is heated up again, and then continue to work in the steam turbine. "Furnace" is the combustion system, its task is to make the fuel burn in a good furnace, heat. It consists of the furnace, the burner, ignition means, air preheater, the smoke duct and the furnace wall, frame and other components. (1) furnace. It is transferred from the furnace wall and into the water wall for fuel combustion, the fuel combustion in suspension, the release of large amounts of heat within the space. (2) burners. Located on the furnace walls or corners, its role is the fuel and air injected into the furnace at a constant speed, so that it can be well mixed in a furnace in order to ensure timely ignition and rapid and complete fuel combustion. DC sub-burner and swirl burner two basic types. (3) air preheater. Located in the boiler backpass, whose role is to use waste heat of flue gas to heat the fuel required for the combustion air, exhaust gas temperature can be further reduced not only, but also for strengthening the furnace combustion, improve the economy of combustion, pulverized coal drying and conveying is advantageous of. Boiler efficiency can be increased by 2%. And rotary two kinds of charge. (4) smoke duct. From the furnace wall is a pipe, the pipe heating surface and the portion of the tube wall and other components of the package, for guiding the flow of flue gas through the heat exchanger and the respective heating surface, and is divided into horizontal flue backpass. Auxiliary ventilation apparatus comprises auxiliary equipment (delivery, induced draft fan), a fuel transportation equipment, milling system, in addition to ash and dust removal equipment, desulfurization equipment.

Horizontal 0.5 tons supervisory inspection-free amount of gas 5 ton coal fired steam boiler in canada is how much? There are a lot of users call and ask when will the relationship between the amount of gas steam boilers are, of course, this problem is related to the user's operating costs, and all of us today about 0.5 tons of horizontal gas-free amount is how much steam boiler inspection supervisor . First to introduce my company developed its own supervisory inspection-free steam boiler, only about 110 degrees this steam boiler exhaust gas temperature, and ordinary steam boiler exhaust gas temperature as high as 250-350, saves considerable steam boiler if the index is to see its exhaust gas temperature, exhaust gas temperature is lower fuel burn more fully explained in the furnace, the more fuel is absorbed by the heat from the steam boiler, the more fuel-efficient, the company supervisory inspection-free horizontal 0.5 tons of steam per hour coal boiler is about 40-50 kg, Common horizontal 0.5 tons coal consumption is about 70-80 kg.

Cade Shopping Mall is located in central Shanghai Hongkou District, Shanghai Daily larger flow of people in the region. The introduction of Shanghai air pollutant emission standards, boiler flue gas emissions of nitrogen oxide emissions to less than 80 mg / m, Shopping Mall a coal-fired boilers have been used for many years, NOx emissions far super to this request, the urgent need to replace more environmentally friendly low nitrogen emission boilers. Other units through the use of fast Boiler introduction and understanding, determined and fast boiler to achieve cooperation, party fast to their specific needs to recommend one condensing gas hot water boiler of a 4.2MW for heating needs of the shopping center.