Steam Boiler Dealer 6 Ton

Fast boiler also has a boiler industry-leading cloud service system, users use the site each boiler are closely linked to the after-sales system, system timing boiler full range of checking and monitoring the daily operation of the boiler once the abnormal situation immediately triggers an alarm, devices and notify management personnel of the boiler, to avoid a great extent on the accident.

Hot water boiler heating industry is our essential equipment, gas hot water boiler water provided by the party fast flotilla, high thermal efficiency direct savings on fuel costs of inputs for our company, the intelligence facilities let the boiler run more convenient and effective to reduce the labor intensity of fireman people. --customer feedback

Burner gas boiler after damage for the boiler is very influential, so users among normal use, strengthen the adjustment and control of boiler operation, including the timely grasp the changes of gas pressure and quality, to ensure that gas and hot air reasonable proportion of fire gas was observed, adjust the size of the second damper, when necessary need to change the angle of operation of the operating layer, when the low load conditions change, to adjust the negative pressure within the boiler good combustion, gas and the ratio of hot air, to ensure coordination with the furnace flame is not good west of the layers gas opening.

Vertical coal-fired steam boiler dealer 6 ton pressure gauge purchase What are the requirements? Each vertical inter-fired steam drum must be fitted with a pressure gauge (potshell) directly connected to the vapor space, the pressure gauge should be installed in the following areas: vertical pre-fired steam feedwater control valve; separable economizer outlet; between the superheater outlet valve and a main steam; vertical start fired steam separator; soda valve system before the first vertical-fired steam; forced circulation boiler water circulating pump out of the pot, the inlet ; a reheater inlet. For rated steam pressure less than the vertical-fired steam 2.5MPa, the pressure gauge with an accuracy not less than 2.5; the rated steam pressure greater than or equal to the vertical-fired steam 2.5MPa, the accuracy of the pressure gauge should less than 1.5; gauge should be selected according to the working pressure. Vertical limit gauge dial scale coal-fired steam should be 1.5 to 3.0 times the working pressure, suggested the use of 2 times; the vertical size of the dial gauge fired steam boiler fireman shall ensure that personnel can clearly see the pressure indicator value , dial diameter not less than 100mm. Vertical coal-fired steam boiler optional pressure gauge should comply with the relevant technical standards, vertical coal-fired steam boilers calibration and maintenance should be consistent with national metrology department. Pressure gauges should be verified before use and indicate the date of the next check. It should draw the red line indicates the working pressure gauge on the dial. We should seal the gauge calibration.