Tel No. (+86) 371-55629010

Harga Coal Oil Boilers

The reason the gas harga coal boilers burner increased noise analysis when making use of the gas boiler and found this small fire normal, but this time turn the fire, extinguished or flashing instability. First speaking, that is because of this fire damper of the air volume setting is too large; i.e. after an oil fire because the micro-switch valve (damper outermost that group) inappropriate setting (set lower than the fire damper of the air flow larger) burner gas noise increases, mostly because the oil shut-off valve which is closed or lack of oil into the oil filter clogging; or, this is because of low temperature into the oil, the viscosity is too high or the pump into the oil temperature is too high; oil pump failure; fan motor bearing damage; there is because the fan impeller dirty equipment resulting in large noise. The above-described failure when using gas boiler, but also because the viscosity is too high oleaginous easy to be atomized (heavy oil); cyclones and because improper disc and the nozzle pitch; Note that because the fire is worn or dirty nipple; also because this preparatory tank the heating temperature is too high, causing the oil pump oil feed steam does not conform; or because the fuel inside the boiler resulting aqueous oil. When the above-described fault gas boiler used to perform this process, the test should be done gradually decreases; after heating temperature should be; adjusting the distance (between 0 ~ 10mm); clean or replace; is set to about 50 deg.] C to about; or drain oil change.

Select the first steam harga coal boilers to know what parameters? Steam boilers have the following main parameters: 1, Rated evaporation Rated evaporation is power steam boiler, steam boiler is the most important parameter, usually expressed in tons evaporation, that is, we usually say how many tons of boiler. 2, rated steam pressure rated steam pressure means that the steam pressure generated in the steam boiler, generally expressed in MPa or kg. 1MPa is 10 kg, like laundry, all hospitals, factories and the like conventional steam occasions the general use of low-pressure steam 1.0MPa or less. Only when using steam as a power to require the use of high-pressure steam. 3, where the steam temperature of said steam temperature, refers to the temperature of saturated steam. Saturated steam pressure and steam temperature are corresponding. Temperature of saturated steam at a pressure of 1MPa 184 ℃. 4, gas / oil / gas consumption fuel consumption is an important indicator of concern when choosing a steam boiler, which is directly related to the use of the running cost of the boiler. In the operation of the boiler, the fuel cost is very impressive, if just considering the purchase cost of buying a cheap but high energy boiler, which led to the late high operating costs, certain that it will be wasted. 5, the thermal efficiency of fuel consumption with the boiler thermal efficiency of boilers is inversely proportional. The higher thermal efficiency, lower fuel consumption of the boiler. Boiler thermal efficiency expressed as a percentage, the value is a more intuitive. 6, the boiler operating weight, size or location in the election of the steam boiler, it should find the place whether the load per unit area can withstand the weight of the steam boiler, and if there is enough space to place the steam boiler maintenance and reserve space.

1-20 ton wns oil and gas harga coal boilers

The wns series oil and gas boiler produced by ZG boiler is a boiler with small capacity, high efficiency and high degree of automation.

It provides fast side of harga coal boilers equipment, installation and commissioning after all normal, we immediately put into use, the hotel did not delay the normal heating. Meanwhile boiler capacity, energy efficient, fully able to meet the needs of heating and bathing water in our hotel rooms. --customer feedback