kent boiler maintenance

Fangkuai Company has a fully-automatic PLC intelligent control system designed and developed by itself with complete intellectual property rights. It adopts a combination of mechatronic control equipment and a programmable logic controller (PLC). Take the advanced programmable logic controller (PLC) as the "central processing unit" of the control system. The control system is operated through the touch screen, which greatly improves the degree of automatic control and operation reliability of the kent boiler maintenance, and the operation is simpler and more intuitive.

Manufacture and use of hot water kent boiler maintenance security risks exist: the manufacture and use of hot water boiler security risks exist though boiler is not subjected to the pump pressure applied to the ring, but at all times are under boiler water storage tank to provide high static pressure the higher the floor, the higher the static pressure hot water. Pressure hot water boiler installed on the exhaust pipe main body diameter is too small, only some exhaust pipe diameter Ф20mm, can not quickly discharge the steam generated in the furnace out of the boiler body to withstand a certain pressure there is a certain risk . Inspection found a rated power pressure hot water boiler is 30 million kilocalories, exhaust pipe on the body is Ф20mm, due to lack of discharge capacity, steam pressure generated in the furnace up to 0.15Mpa. The larger the rated thermal power boiler, steam pressure generated in the furnace of the greater, the greater the risk.

Large volume of combustion chamber. Large volume design can meet a variety of needs. In order to obtain low thermal load, the kent boiler maintenance chamber with a large capacity can guarantee the full combustion of the gas or liquid fuel. the temperature can be spread evenly so as to avoid the blocking and protect the tube and the baffle.

About related features hot water kent boiler maintenance, what does:? Hot water boiler with leakage protection function (the control system detects electrical leakage when the power is automatically cut off power boiler), anti-dry low water protection (water level below the set the lowest limit level immediately stop and alarm), thermal protection furnace (boiler start automatically when the temperature exceeds 105 deg.] C the boiler shell, immediately shut down and an alarm, the normal temperature), the temperature sensor protection function (control system keeps detecting sensor condition , the alarm and immediately stop), the power supply voltage protection function (power supply abnormality, the automatic power-off. after the normal, automatic recovery operation), the heating assembly phase protection function (monitoring phase after heating assembly, shutdown protection).