Tel No. (+86) 371-55629010

Condensing Boiler 6t Dealer Georgia

Exhaust gas has been plagued by sewage paper industry, paper industry pollution problems of the country very seriously. Fujian Heng paper packaging company has been committed to the use of clean-type condensing boiler 6t dealer georgia paper processing. October 22, 2016, David Carse, the paper with my company, signed a 6 tons of steam an integral condensing steam boiler for the production of corrugated cardboard and other paper products. I provided the boiler greatly solve the problem of sewage wastewater Heng paper. After the boiler operation, both to meet local environmental requirements, but also reduce operating costs for the constant boiler paper products.

If natural gas condensing boiler 6t dealer georgia in case of emergency, such as boiler water, burst pipes and other reasons, this is an immediate need to shutdown for maintenance. In general, natural gas boiler shutdown of the following two cases.

Why sugar mill need steam condensing boiler 6t dealer georgia

Sugar making process require steam and therefore it requires a boiler. One of the byproduct of sugar making process is bagasse which is a biomass fuel that can be used in boiler. Therefore, sugar plants typically has bagasse fired boilers – typically fuel firing system used is stoker firing.

Basics 1 condensing boiler 6t dealer georgia maintenance, gas-fired boiler during operation Note the following points: (1) does not allow pressurized combustion gas boiler or furnace smoke, easy to burn out because stoker hole cover. Not on the bottom of the water (2) Gas boiler ground surface to prevent moisture corrosion. 2, gas boiler run every 2-3 weeks, should be checked once. 3, gas boiler run every 3-6 months after the shutdown should conduct a comprehensive inspection. (1) on the inside and outside gas boiler inspection, such as pressure welds, corroded steel inside and outside part of the phenomenon, if found should be repaired in a serious flaw, if the defect is not serious next time also to be shutdown to repair, if found when there is suspicious, but does not affect safety, records should be made for future reference. (2) can be checked and the water boiler primer coating to prevent corrosion. 4, gas boilers and boiler base paint at least once a year. 5, maintenance of gas boiler normally unused methods: dry and wet two kinds, one month shutdown, care should be taken dry method, wet shutdown can be less than one month regimen. (1) Dry regimen: the boiler furnace shutdown to discharge water, the inside completely remove the dirt, rinse, drying in the furnace with Weihuo (be careful not to fire), and a diameter of 10-30 millimeters block quicklime installed sub-plate, placed in the drum, without contacting the metal with lime, quicklime weight, calculated to the drum 8 kilograms per cubic meter volume, and then all of the manhole, the pipe valve closed hand holes, each of three months, check again, such as lime ingredients like broken, i.e. the need to replace, should be re-run the boiler and the lime disk unloading. (2) Wet regimen: After Shutdown of the water discharge released, the internal completely remove the dirt, rinse, refill treated water to the full, the water was heated to 100 deg.] C oven, so that the water discharge gas outside of the furnace, then close all the valves, cold climates where moisture can not support the use of law, so as not to damage the boiler furnace water freezes.