Tel No. (+86) 371-55629010

coal for steam boiler for sale petaling jaya

Cade Shopping Mall is located in central Shanghai Hongkou District, Shanghai Daily larger flow of people in the region. The introduction of Shanghai air pollutant emission standards, boiler flue gas emissions of nitrogen oxide emissions to less than 80 mg / m, Shopping Mall a coal-fired boilers have been used for many years, NOx emissions far super to this request, the urgent need to replace more environmentally friendly low nitrogen emission boilers. Other units through the use of fast Boiler introduction and understanding, determined and fast boiler to achieve cooperation, party fast to their specific needs to recommend one condensing gas hot water boiler of a 4.2MW for heating needs of the shopping center.

The reason gas coal for steam boiler for sale petaling jaya flame of abnormal phenomena and processing method. Flameout for the following reasons: 1. Auxiliary trip or power interruption. 2. boiler combustion instability. 3. When the load is too low, due to the sudden drop in load, ignition energy mill will be lost or the combustion is automatically stopped. 4. mutation coal, low volatile or low calorific value. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. 5, the automatic combustion flame detectors or failure resulting in failure to trip mill. 6. The furnace wall or squib serious improper boiler soot-blowing operation, a large amount of steam into the combustion chamber. 7, coal pulverizing system, fuel system failure, resulting in a substantial amount of fuel reduction or interruption. A large amount of water or impurities in the fuel oil gun clogging, or atomized vapor pressure is too low. Second, the phenomenon: 1, furnace pressure was significantly higher, flameless furnace flame monitoring CRT display. Pit of fire no fire. BTG MFT alarm window alarm indicator lights. 2. The unit load is reduced, steam flow drops rapidly, and the temperature of each section of the working medium vapor pressure decrease, a sharp increase in oxygen index. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. 3. Treatment: 1. If you refuse to run MFT protection, emergency stop should be handled according to the situation and stop the supply of fuel. 2.2. Identify the cause of stalling, and try to eliminate it. Conduct a comprehensive inspection of the boiler, and to confirm proper before the device is restarted.

Calculated gas coal for steam boiler for sale petaling jaya plant to explain your boiler heating area: Gas-fired steam boiler plant to you to explain the calculation method of gas steam boiler heating area of ​​the boiler, which is sure to install emissions-line monitoring devices, and, should environmental protection department of the monitoring center networking, so the job. And this kind of boiler heating area, specifically, then, is to be determined according to the location of the boiler, its usage and requirements. Generally speaking, if it is 1 ton, then, it is about 7000 square meters of heating area. 4 tons of gas steam boiler, which uses induced draft fan, then, that in the selection and configuration, generally speaking, if a different motor, then, there is a different choice, but specifically, then, is there are two First, Y5-47-6C, power is 15KW / 18.5kw, grade 2 is a motor; Second Y6-41-7.1C, power is 15kw / 18.5kw, the motor is four. 10 tons of gas steam boiler, between it and the workshop is to have a safe distance, and can not be a piece design, it must be independent. Therefore, it is generally to be more than 5 meters, so the job, however, can also be separated coal field.

Factors that affect factors superheated steam temperature changes affect food factory superheated coal for steam boiler for sale petaling jaya plant food temperature variation effects superheated steam boiler temperature variation food factory, 1, 2 changes, and the air volume ratio of 3 changes, burner fuel properties and 4, 6, 7, change the saturated steam temperature change and desuperheating water flow operation mode change in water temperature in the pulverizing system 5, the heating surface cleanliness variation boiler load variations. Change in fuel volatile carbon content, calorific value and the like: 1. Variations in the nature of the fuel. When the roughening coal, fuel combustion in the furnace a long time, the center of the flame increases, the steam temperature. When the fuel water is increased, the heat absorption of water evaporation furnace, the furnace temperature is lowered, the increase in humidity, but also increases the volume of the flue gas, the flue gas flow increases, reducing the superheater heat radiation, convection superheater heat absorption is increased. 2. And change the air volume ratio: when increasing the oxygen content of the furnace, the low temperature due to heat absorption of cold air, the furnace temperature is lowered, the furnace outlet temperature. At a total gas flow is constant, a change will also cause shifts air distribution steam temperature. When a low flow rate is insufficient, part of incomplete combustion of pulverized coal, the flame center is moved upward, the furnace exit gas temperature. 3, changing the operating mode of the burners and pulverizing system: operating system will result in an upper pulverizing the steam temperature is increased, the swing angle of the burner changes, the change in center of the flame, steam temperature changes.