Tel No. (+86) 371-55629010

superac boiler agents south africa

Henan steam superac boiler agents south africas running fast boiler company to introduce small series with the normal operation of steam boilers. Requirements normal operation of the steam boiler: furnace normal water level, steam pressure stable, keeping the boiler room tidy, do shift work to strengthen the monitoring of equipment and instruments to ensure the safe and reliable, to prevent accidents, pay attention to saving coal, fireman to regularly summarize experience, and continuously improve operation and management level. 1, water steam boiler feed water requirements need to be processed, the water supply must meet the requirements GB1576-85 "low-pressure boiler water quality standards", it requires the use of automatic continuous water supply mode, to avoid vapor pressure fluctuates due to discontinuity Sheung normal operation of boiler, for affecting the normal vapor. 2, the water level in the furnace steam boiler furnace always pay attention to water level changes, so as to maintain the normal water level in the range of ± 25 mm can not be higher than the highest or below the minimum level, the water level within the water table generally slightly shaking stationary phenomena such as water , there may be blockage in the water table, it should be washed immediately. 3, steam boiler water level gauge water level in each class should be washed at least once, the water level to maintain regular cleaning, make sure the water level is clearly visible. The glass mat should be found to leak, steam leakage when tightening the packing, such as water or water line blurred not clear, flushing effect still not be replaced. Each boiler is equipped with two water level, which if a damage should be repaired immediately, such as the two also damaged, immediately temporary shutdown until a water level returned to normal in order to continue operation. 4, when the steam boiler water supply equipment to shift to check all the pumps are working correctly, if the fault repaired immediately. Boiler feed water requires continuous feeding, the amount of use of automatic water regulating valve to open the control valve, the boiler feed water is automatically adjusted according to the size of the steam consumption. 5, the vapor pressure remains stable as possible working pressure, vapor pressure shall not exceed the rated working pressure. 6, the bending tube pressure gauge gauge class washed once and check whether the normal pressure gauge, a pressure gauge check every six months, as a difference between the atmospheric pressure reading shall be repaired or replaced.

Fast superac boiler agents south africa is a very trustworthy business, whether it is the beginning of cooperation or boiler put into operation, such as a party soon have maintained cooperative attitude, patience, careful. To ensure long-term stability of the latter part of the boiler operation, fast boiler technician fireman's gave us a free people to do the training, precautions and reduce the accident rate method full guidance boiler operation. --customer feedback

The rated output of the superac boiler agents south africa and boiler efficiency is determined, the fuel consumption is calculated, and then selected according to power a single burner arranged to determine the number of burners. Increase the number of burners, in favor of the atomization quality assurance wind oil mix, but too many, and not easy to operation and maintenance, will give burner arrangement difficult. Adjusting the burner to a large extent, be able to adapt to changes in boiler load, to ensure complete stable combustion under different conditions.

Third, post-maintenance

When selecting steam boiler, boiler maintenance problems later also various food processing companies need to consider. Fast boiler-based networking, cloud computing platform, designed to develop cloud services 3.0 system, you can view all boilers case is being used in the system, and features a variety of alarm alerts, real-time monitoring use of the boiler. When the user site due to improper operation or other unexpected circumstances leading to the boiler is not working, fast square corresponding technicians via phone or Internet, the user informed of the situation, solve the problem.