boiler autoclaves jambi

Henan burner safety controls in claim 1 gas boiler autoclaves jambi, gas boiler burner pre Henan Henan hair gas boiler before ignition burner, there must be a period of pre-blowing, the furnace and the flue gas blow-off I or dilution. Because the gas inevitably leave more than work within the furnace burner, if not pre-ignition and hair, there is the risk of explosion. I have to blow off a clean gas or dilution gas concentration does not ensure the explosion limits. Pre-blowing time of the furnace structure and the amount of hair is generally about 15 to 60 seconds is provided. 2, Henan gas boiler combustion engine auto-ignition combustion spark-ignition engine should be adopted, to facilitate automatic control. Available high-voltage ignition transformer arc ignition, which required energy output: voltage ≥3.5KV, current ≥15mA, the ignition time is generally: 2 to 5 seconds. 3, Henan gas boiler burner combustion state monitoring Henan gas boiler burner combustion state must be dynamic monitoring, once the flame detector flame sensed signal must be fed to the burner in a very short period of time, then the burner into the protected state , and cut off the gas supply. To the normal flame detectors sensing flame signal, neither sensitive nor slow. Because sensitive, Henan gas boiler burner combustion state if volatility prone to malfunction and slow, feedback flame signal lag is not conducive to safe operation. General requirements for the response time of a signal sent from the flame to flameout flame detector does not exceed 0.2 seconds. 4, when the gas boiler burner Henan misfiring burner ignition protection, into a gas, combustion gas ignition. Ignition operation request occurs before the gas passed into first ignition temperature field is formed, to facilitate ignition and combustion. If the misfire, flame detector can not sense the flame signal, burner protection status. Protection state from the ignition time to be appropriate, neither too short nor too long. If it is too short, a stable flame is formed too late; too long, causing a large amount of gas into the furnace when the misfire. General requirements in 2-3 seconds into a gas, flame burner flame detector signal sensed be determined, not the fire protection state, ignition combustion is maintained. 5, Henan gas boiler burner flame protection Henan gas boiler burner in the combustion process, if unexpected flameout, burner into the protected status. Since the furnace is hot, the gas enters prone to knocking, it should be a very short time into the protected state, cut off the gas supply. From the burner to the flameout into protected state, the response time of the process requires less than one second.

20 tph SZL coal-fired steam boiler autoclaves jambi for wine industryThe fermentation and distillation in wineries require a relatively large amount of steam. If heating and bathing heat are superadded,more steam will be needed. Therefore, coal-fired steam boilers are the preferred boilers for fermentation and distillation in wineries.In order to meet the need for production expansion, Kouzi Liquor reached and analyzed the boiler industry, and after repeated consideration, Kouzi Liquor purchased 20 tph SZL coal-fired steam boiler for the production of white wine. In oeder to reduce the coal consumption and improve the economic effectiveness of Kouzi Liquor, ZOZEN did partial improvement of water and air supply technology, which can reduce the cost of steam production.

Determination of Gas boiler autoclaves jambi water on a gas introduced through a gas boiler incineration operations: incineration of carbon-based fuels thereof containing oxygen, carbon dioxide and steam occurs, escape from the top or the side of the stack, it referred to as a flue. Such planning trouble is that a lot of heat can escape from the exhaust gas. Escape the heat means wasting energy, it will cost you money. Another system is known as the condensing gas boiler, the flue gas passing through a heat exchanger, which heats cold water from the heat sink back, the exhaust gas temperature after the recovery of only about 60 ℃, so heat power probably increased by about 10%, savings of natural gas by about 10%, while the energy recovery process, you can also reduce harmful gas emissions, reduce environmental pollution. Condensing gas boilers like this can reach more than 90% power (more than 90% of the original energy into energy to heat your room or hot water). How to compare the traditional and the modern, non-condensing gas boiler condensing gas boiler 1, different incineration technology. Condensing boiler operation under normal operating conditions, gas and fresh air was mixed burning, burning completely high power, low emission targets. However, the practice is not possible to reach the gas-fired boiler burning thorough mixing ratio, a large heat loss, but condensing boiler does not present this problem. Condensing boiler with a new technology, high cost, so its price will be higher than the average boiler. 2, the use of different age. Since the conventional gas boiler incinerator, burning chamber and other key components, plus water quality and other issues, will make use of the product life decline. With inlet incinerator normally condensing boiler service life due to its advanced technology, the use life is generally greater than a conventional gas boiler. 3, different energy saving. Usually conventional gas boiler heating power can reach only 92%, because the conventional high-temperature exhaust gas boiler, the fuel burned in the water occurs when superheated steam conditions in the flue gas, is lost with the flue gas from the stack, reducing thermal power. Condensation boiler thermal power is greater than 95%. During incineration may be the exhaust gas temperature is reduced to 50 ~ 70 ℃, it is very energy efficient. Water quality measurement process and the measurement gas boiler 1 chloride specification taken in boiler water 100ML measuring cylinder 250ml conical flask, to participate in 2-3 drops of phenolphthalein indicator, was pink, then titrated with sulfuric acid to colorless, participate 2-3 dropwise potassium network indicator, standardized silver nitrate solution was titrated to red jujube, the volume number of the silver nitrate consumed record, namely 35.5 multiplied chloride specification: 4002 Determination of chloride less alkalinity boiler water take measuring cylinder 100ml to 250ml conical flask, to participate in 2-3 drops of phenolphthalein indicator, the solution was pink, was titrated with sulfuric acid to regulate just colorless, then add 2-3 titration methyl orange indicator, titrated with sulfuric acid continued to orange red stopped, the volume of sulfuric acid consumed number record, the size of this measured value is equal to 3 hardness alkalinity boiler water 100ml measuring cylinder taken to a 250ml Erlenmeyer flask, to participate in a few grains Los black T indicator, then add 2 -3 dropwise ammonia - ammonium chloride buffer solution with standardized EDTA solution was titrated to a wine red solution turns blue end record number EDTA solution volume consumed, this value is equivalent to the size of the boiler water hardness. Specification: Hardness: Determination steam oven 0.6mmol per liter or less per liter of the water heater 4 pH measured 0.03mmol Specification PH test paper: PH value: 10-12

According to our learned Wenzhou Municipal People's Government on February 12 issued a notice "Wenzhou Blue Sky win the Battle of action to implement the program (draft)", the details are as follows.

Accelerate the implementation of the relevant arrangements for the deployment of national, provincial and develop natural gas and other clean energy. According to Yi gas of the gas, the electric power should be the principle, and actively guide enterprises to implement energy clean energy alternative, 2020, the basic completion of provincial trunk pipeline construction, the basic realization of natural gas every county, to further improve the urban and rural distribution pipe network construction , the city's natural gas consumption reached 570 million cubic meters, the proportion of non-fossil fuels in total energy consumption to reach the provincial requirements. Orderly development of hydropower, safe and efficient development of nuclear power, optimizing wind energy, solar energy development layout, local conditions to develop biomass energy, geothermal energy and so on. Where the conditions of availability of resources, to encourage the development of county biomass cogeneration, biomass briquette boilers and biogas. Orderly development of natural gas peaking power plants and other interruptible user, in principle, to new natural gas cogeneration and gas chemical projects. Continue to implement the priority generation and purchase of electricity system to ensure the city's renewable energy generation full protection of the acquisition.

Strict new coal project access, the implementation of the reduction of coal instead. According to the State to win the Battle of the sky three-year action plan calls for no new 35 steam tons / hour high-polluting fuel boilers. By 2020, the city's coal accounts for the proportion of total energy consumption fell to 42.8% or less, the city's total coal consumption decreased by 5% compared with 2015. According to focus on the use of coal and clean use of principles, focusing on reduction of non-coal for electricity, increase the proportion of electricity from coal in 2020, the city's electricity and central heating coal proportion of total coal consumption reached provincial requirements. Continue to promote alternative energy coal and oil, replace reached the provincial requirements.

For shutting down the unit's capacity, coal consumption and emissions targets, allowed to trade or replacement, can co-ordinate arrangements for building the capacity of ultra-low emission coal-fired units. Strict control of new coal-fired units installed capacity in the region rely on new clean energy generation and transmission to meet outside the main electricity consumption. In the premise of protecting the power system security and stable operation of 2020, to accept the outgoing power levels to at least 38%.

Consolidate construction achievements combustion zone ban, increase efforts to eliminate small coal-fired boilers. According to the National to win the Battle of the sky three-year action plan calls for phasing out the 10 steam tons / hour and coal-fired boilers, the county level and above urban area basically out of coal-fired tea furnace, operating a stove, grain storage and drying equipment, etc. facilities; basically eliminated the city's 10 steam tons / hour and 35 steam tons / hour of coal-fired boilers; 35 steam tons / hour and more polluting fuels and energy-efficient boilers to complete the transformation of ultra-low emissions; low nitrogen gas boiler basically completed the transformation; city built-up area of ​​biomass boilers implement ultra-low emissions transformation.