Tel No. (+86) 371-55629010

technical specification of boiler

Input condensing gas technical specification of boiler is in a volume of gas multiplied by the gas heating value (taking into account the influence of the air temperature, air pressure, humidity, heat calculation), different conditions of factors determine the calorific value of the gas has a high calorific value and low calorific value points.

Fuel oil-fired technical specification of boiler boiler water filling operation process in preparation for the next cold case into operation, we must first understand the boiler water filling system without fault, and therefore should be done before firing boiler water filling trials to test boiler water filling system is normal, pipeline The valve leaks. Operating Procedure: (1) upon inspection of boiler meet the operational requirements, in order to carry out work in Sheung Shui boilers; before (2) Sheung Shui, you must get in touch with the boiler water quality testing staff to ensure that water treatment is working properly, to avoid affecting the boiler water filling; (3) open the power, boiler exhaust valve opening, to start the pump, check the boiler water pressure greater than the working pressure, to open the valve, to boiler Feed; (4) fuel boiler Feed simultaneously, open the drain valve drainage , the inner opening the drain valve, the drain valve opened outward, outer closed drain valve, the drain valve closed inner, outer 2nd opening the drain valve, 2nd outer drain valve closed, after rinsing pot, close the drain valve to continue on to the boiler water; (5) the pot water level reaches the normal level, to turn off the water supply pump is stopped, the exhaust valves; (6) for water drainage test table, the drain valve open water table, the water table confirm normal, closed drainage water table valve, waiting for ignition. Sheung Shui operational matters should be noted: Sheung Shui to oil-fired boiler water level should not exceed the normal water level, because when the boiler ignition, the boiler thermal expansion of water, the water level rise would exceed the maximum safe water level. If this happens, the water level should be adjusted by sewage.

65bar gas fired technical specification of boiler in Pakistan

Gas fired Boilers in Pakistan

Wuhan Yu Dahua Group Co., Ltd. is a cotton based, weaving, knitting and textile car decoration installation in one of the cross-industry, diversified and comprehensive export-oriented enterprise groups. 2017, the Group expanded production scale textile processing, the number of new production lines, the Group's original steam technical specification of boiler can not meet the growing demand of orders in urgent need of a new steam boiler purchase. When selecting vendors steam boiler, the boiler output device side fast sustainable high quality steam attracted, decided to cooperate with the fast boiler. Fast art by side to the user site needs analysis, to provide two integrally condensing gas steam boiler (WNS4-1.25-Y.Q).