As a type of gas fired boiler manufacturers in uae , WNS gas fired steam boiler is designed in three-pass flame tube/smoke tube structure with the rated evaporating capacity of 1-20 ton.The horizontal gas fired steam boiler for sale is characterized by a very compact construction.

Gas steam boiler manufacturers in uae water level gauge of what common fault? Gas-fired steam boiler in the course requires a certain capacity to use water, if the water in the furnace too little can cause dangerous, so gas steam boiler water table has a very important role, if the water table is necessary and timely investigation and treatment failure . Following on from the hot gas steam boiler manufacturers to introduce common faults which have water gauge. 1, there are low-lying water table or use the water level indicator active when only a water table when gas steam boiler with a low water table when the drum is only a case of the water table, because the low water table balancer internal short circuit leakage, low water table caused by the emergence of high water, the so-called "full of water", and the water table on the drum performance but low water, and even see the water level, then the fireman because they can not immediately determine gas steam boiler actual water level and the water level will go to check on the drum table, it may be severe water boiler accidents occur because of delays. After discovering this case, the low water level should be checked as soon as possible balancer table and give treatment. 2, cocks on the water gauge screw fixed gas steam boiler water level gauge long time without cleaning operation time, but also lack the necessary daily maintenance will cause water gauge cocks rust, gas, water and even the block, or insufficient packing aging or deterioration, so the above symptoms should be given replacement and maintenance in the future use on a regular basis. 3, the performance of the water table water table fake gas steam boiler water level of the phenomenon of false water level, in addition to gas, water or even tube cock is blocked, but it could be gas, water pipes and even the water table due to dislocation connection, as well as steam water tap handle installed the wrong position caused cocks closed, or because of poor water quality, the boiler priming and thrown false water level. As long as careful to exclude targeted treatment. A wide variety of gas steam boiler manufacturers to introduce common failure of several water table, due to the water table is a device that displays boiler water capacity, the gas has an important role to ensure the safe operation of steam boilers, so the fireman must pay attention to, if found abnormal water table is necessary and timely for maintenance treatment.

Since Prime Minister Li Keqiang in the "five" proposed "Blue Sky Wars," after the strategic plan states that China provinces and cities are doing to improve environmental protection. Jilin Provincial People's Government recently issued a "Jilin Province to implement the winning Blue Sky Battle three-year action plan to implement the program," coal-fired units will conduct a comprehensive reform.

Jilin Provincial People's Government recently issued a "Jilin Province to implement the winning Blue Sky Battle three-year action plan to implement the program" (hereinafter referred to as the "Program") said that before the end of 2018, the province's 300,000 kilowatts or more coal-fired units completed ultra-low emissions transformation. Continue to promote the 200,000 kilowatts class ultra low emission coal-fired unit renovation project, before the end of 2019, ultra-low emissions and strive to transform the province's total unit capacity of thermal power capacity of more than 75%.

"Program" also proposed to complete the transformation of ultra-low emission electricity generation units appropriate to increase the number of hours. Vigorously for shutting down environmental protection, energy consumption, safety and other 300,000 kilowatts coal-fired units of non-compliance. Coal-fired generating units to increase the technological transformation efforts, speed up the heating pipe network construction, fully release and improve the heating capacity, eliminate coal heating boiler pipe network coverage and the range of loose coal. In areas do not have the cogeneration district heating conditions, the existing multiple small coal-fired boilers, alternative construction of large-capacity coal-fired boilers in accordance with the principle of equal volume. Before the end of 2020, within a 15 km radius of 300,000 kilowatts of heating and cogeneration power plant above range, in the case of cogeneration heating load to meet the heating needs, in addition to the need to retain the peaking boiler, coal-fired heating boilers and small coal-fired thermoelectric behind all closed down integration.

In addition, long-term control of total coal consumption in accordance with planning requirements, Jilin Province, to continue to reduce the amount of coal consumption, coal consumption in new coal projects to implement alternative reduction, by 2020, reduce the proportion of coal accounting for the province's total primary energy consumption to 63% the following. According to focus on the use of coal and clean use of principles, focusing on reduction of non-power coal, increase the proportion of electricity from coal, the state-assigned task is completed, the province's electricity by 2020, the proportion of thermal coal coal consumption reached more than 55%.

In the future, the province will carry out a comprehensive environmental aspects of governance, economic development and environmental protection go hand in hand.

Let's look at the causes of hot water boiler manufacturers in uae corrosion it.

1, does not control the supply of water, a 2.8MW hot water boiler, pay hundreds of tons per day, but more often, do not need to make up so much water.

2, not to seriously implement the "low-pressure boiler water quality standards", the standard clearly states, when the water temperature is ≤95 ℃, circulating water should be controlled PH value of 10-12, which is a very important indicator, but some units do not be error is supplied by the hot water boiler steam boiler water standards.

3, the hot wire mounting network failure, the user can not send the circulating water system ends. Increasing the number of exhaust air, heat will drain, not exclusively to cool, resulting in an increase of the amount of leakage.

4, may also be a constant pressure expansion tank and the boiler inconsistent. Height of less than 15 meters, but the boiler constant pressure to 2.5kg / cm2, fireman to maintain 2.5kg / cm2 working pressure indicators, regular pay, for no apparent reason the water overflows into the ditch, the water was wasted .