Tel No. (+86) 371-55629010

high quality brown coal hot water dhl boiler

Electrical difference between the high quality brown coal hot water dhl boiler and gas boiler no real good, only for it or not. (Direct thermal electric boiler in the building standards are not allowed in the following description of an electric thermal storage boilers, there is a corresponding electric thermal storage boilers local standards) investment aspects of the common gas boiler cheaper than electric boilers at the beginning, but also the gap between the number of specific distinction, gas brand boiler size, with or without condensate recovery and technical maturity; brand electric boiler, the applicable type. Related both construction conditions, such as plumbing, gas station; selecting high and low voltage power, power distribution construction. Gas heating season in general calorific value / purity of non-compliance (even if the contract is more explicit), compared with the calorific value of the basic electrical 1: 7, the proportion of LNG to be higher, lower coal bed methane (calorific value is multiplied by the thermal efficiency of the device ). In this case, electricity savings of about 1/3 than gas, according to the grapevine, is expected this year, Liaoning low power dropped to less than 0.3 yuan (business), that electricity than the gas savings is estimated to be more than half. It covers an area of ​​respect, if the construction of the gas gas station, then it must be a space-saving electric boiler and electric boiler is the basic module assembly, according to the actual situation; and gas boiler explosion venting port and need a certain security area. In terms of energy, electricity is no waste, waste gas, waste water, renewable energy, gas or have emissions, and fossil fuels are not renewable, although the state vigorously outsourcing, but in the long perspective, the decline in the price of more space large, but also more conducive to use, especially Valley electric. Finally, if it is 30 000 m2 of non-continuous heating conditions (such as schools, shopping mall, office, public venues, factory, warehouse, etc.), recommended to choose electric thermal storage boilers, the best choice for 10kv high voltage device, you can save some investment, and the province as well as policy. But if the area is less than 10,000 m2, the election 0.4kv low-voltage equipment is also good. Equipment and electric boilers are run automatically, without someone on duty, usually around six meters do not consider lifting frame height coefficient, the heating time can independently control these areas compared to the municipal district heating is also very advantage.

Four major advantages of condensing gas hot water high quality brown coal hot water dhl boiler. Condensing gas hot water boiler is the relatively large number of enterprise applications, it's at the advantage of it is reflected in where? (1) with respect to the coal boiler, condensing gas hot water boiler does not produce more soot pollution on the one hand of great significance for the protection of the environment, it can also help companies to save part of the exhaust gas treatment costs, (2) because condensing gas hot water boiler is set for example, anti-dry protection, overheating protection in the boiler boiler system and a series of safety devices and features, so the process of running the boiler will reduce the security risk to a certain extent. (3) the use of condensation techniques, can be efficiently condensed by the heat recovery device. Part of latent heat of vaporization of the high temperature flue gas discharged to absorb the boiler, the boiler to reduce heat loss, improve thermal efficiency operation. Small volume (4) condensing the hot water boiler, noise is relatively low. The larger flow, small head, the effect of multiple parallel can be achieved. These advantages condensing gas hot water boiler, use the support it occupies a place, condensation technology in the market, but also really hot water boiler to achieve energy saving effect to some extent, thus saving companies the cost of running a part of.

Hot water high quality brown coal hot water dhl boiler obvious environmental benefits of energy to achieve the sustainable use of hot water boiler pollution-free environment benefits are obvious: renewable biomass as fuel, achieving sustainable use of energy. Staged combustion technique using high temperature, low flue gas NOX, SO2, dust and other emissions, the fuel is a (gas) burner, electric heating the best alternative. Must check before check inside the hot water boiler and used to prepare inspection, inspection in the furnace and the flue, the boiler attachment check, check automatic control system, ancillary equipment, combustion equipment, check the auxiliary heating surface, running hot water boiler do some checks that we are not inconsiderable, it is possible because of our neglect and causing very serious consequences. Therefore, we must as a preventive measure, to carefully check the following before the hot water boiler operation. Including internal inspection and boiler ready to use. Furnace and inspection, fouling and debris inside the furnace and flue in the chimney should be cleaned. Flue duct and damper, the shutter must be complete and compact, flexible switch, opening and closing accurately indicated. Check the boiler accessories, check the safety accessory is intact; cock is rotating flexible, easy to use; all kinds of instruments and controls should be complete, good, clean. After passing the examination, should the gauge cocks in working condition. Check the automatic control system. Check the attached device. Check the combustion apparatus, the combustion apparatus is intact inspection; mechanical transmission system, coal handling system, the ballast system test switch normally; spring-loaded safety level of a gearbox should be appropriate, well lubricated; coal indicate the correct shutter foot eagle iron. neat, well, turn ballast plates full, flexible movement. Auxiliary heating surface of the inspection, check the auxiliary device (fan, blower, pump, etc.) are firmly connected coupling; proper belt tension triangle; oil should be good enough; cooling water flow. After passing the examination, installed security guard, respectively, commissioning, and note the current when idling. Must check before check inside the hot water boiler and used to prepare inspection, inspection in the furnace and the flue, the boiler attachment check, check automatic control system, ancillary equipment, combustion equipment, check the auxiliary heating surface, running hot water boiler do some checks that we are not inconsiderable, it is possible because of our neglect and causing very serious consequences.

After use throughout the winter, the Central Conservatory of Music give us feedback, six V6-99 fully meet the heating needs of the school. And high quality brown coal hot water dhl boiler fuel and water requirements are not high, urban water and low-pressure natural gas combustion can operate. The most important point is that nitrogen oxide emissions are very low and very happy to recommend it to others to do the brother of boiler units. --customer feedback