1 Ton Diesel Boiler Estonia

Sixth, gas 1 ton diesel boiler estonia room layout flexibility, small footprint, low noise generated.

Seven, improve the environment. Produce large amounts of dust coal-fired boiler operation, cause great pollution to the environment. While natural gas as clean energy, the environment has greatly improved.

How to determine the level of small gas steam 1 ton diesel boiler estonia in severe cases, to carry a large amount of water steam, increasing the salinity of small gas steam boiler, water hammer occurs sound steam pipe, the steam from the connection flange drop out; when the water supply It is less than the flow rate of steam flow, or if due economizer tube rupture caused by lack of water, the opposite phenomenon occurs. When the severe water shortage, from the door you can see the red water wall tube, you can also smell the coke. Meanwhile, the tube may crack, this time can be heard the blast, and the vapor and flue gases discharged from the door, fire doors look. Small gas steam boiler when the water level is below a predetermined value, the fan motor should be stopped, the induced draft fan and grate speed reducer, the security level is lower than the low water level, the water level gauge glass (plate) as a white. Rinse water level gauge to determine the small gas steam boiler is full of water and mild or severe full of water. Method: Turn off water level, water plug, then open the drain plug, if they can see the water level from top to bottom, indicating that it is a little full of water, open sewage valve, into the normal water level. If the water is full of serious, due to take urgent measures to stop work.

Installation Notes 1 ton diesel boiler estonia environmental protection boiler should not be installed in the bedroom or the bedroom figured the room. To facilitate installation and maintenance, in place boiler, the boiler and the maximum dimensions of the object, or four weeks from the wall should be less than half a meter. Placing the boiler ground should be flat, rigid, to facilitate drainage. When the boiler is mounted in place, holding the top surface portion of the boiler capacity is lower than the rear 5-10 mm. Displacement and ensure that the boiler does not occur after the sinking operation. The environmentally friendly heating system installation design are by atmospheric boilers, pressure must not be used. Heating the water temperature should not exceed 85 ℃. Circulatory system supply and return water pipe diameter must be consistent with the boiler supply and return water connection diameter shall not be reduced. Supply and return water pipe should maintain a reasonable aspect and slope, main boiler return pipe direction should bow, maintenance, overhaul, should be able to put more than water to make the system. Up and down the main supply pipeline should avoid bending, bulging, protruding local phenomenon. The pipe through the wall, slope liable to change, install with caution. Boiler expansion tank is not less than the total volume of water systems and boiler circulation pump 15 is mounted% 6: circulation pump should be installed on the main supply mains closer to the boiler, a circulation pump to be provided on both sides of the pipeline valve, to facilitate maintenance. Using temperature Importers hose connected between the valve and the pump, to eliminate the noise generated by the circulation pump. It should be set at the same time the bypass conduit, the main supply pipe the same diameter, provided on the changeover valve. During normal use of the heating circulation pump, the bypass line switching valve should be closed. Should be converted to the natural circulation loop by a pump switching valve to open the bypass pipe line, and then close the circulation pump. Bathing mounting system: the system is connected with one end export bath, the other end is connected to the water pipe. When not using this function, you do not have to do anything. Chimney installation: chimney diameter of the mounting height is not less than the list of technical parameters on the boiler chimney. Chimney installation should be vertical, vertical hanging test method may be employed. If deviations can be leveled at the flange connections correction, and to ensure the sealing effect, and the ground support chimney, furnace chimney connection must be firm and reliable. After the chimney installation having a diameter of 5 mm or more of the three wires or cable tension, the degree of tension should be substantially the same three wire. No exceptional circumstances may not set a lateral chimney. If space constraints, you must set the lateral turn, should ensure that the chimney lateral angle from the horizontal portion of angle no greater than 50, the remainder of the vertical. Should be appropriately increased stack height laterally long.

The party hot water 1 ton diesel boiler estonia output fast enough to provide high efficiency, give us save a lot of fuel costs, and exhaust gas discharged tested in full compliance with environmental regulations on emissions of air pollutants in Henan Province. Fast boiler responsible attitude also left us with a deep impression, overhaul maintenance problems for a number of aspects of boiler operation and post, sent a very professional technical staff and our butt, fireman guide our people, for the quick sale of party, we are also very satisfied. --customer feedback