Tel No. (+86) 371-55629010

10t Oil Boiler Dealer Kazakhstan

Combustion Adjustment of dual-use oil and gas 10t boiler dealer kazakhstans (Skills) boiler firing was successful, the load can be adjusted to normal operation. At this point, we should always observe the furnace combustion, if there is a bad oil and gas atomization, beating the flame, the flame hit the furnace and the exhaust gas temperature is too high or too low and so, it is timely for oil pressure, oil temperature, of steam, wind, air pressure, steam pressure hanging line adjustments to ensure safe and economic operation of the boiler. Size and load size of hydraulic, pneumatic boiler related to the oil pressure adjusted by adjusting the back pressure or fuel burner to achieve the size, by adjusting the air pressure to achieve the degree of opening of the valve. Adjust the amount of oil, air pressure adjustment load, at the same time, air volume control, must be synchronized to ensure a reasonable match of oil and the amount of wind, so as to achieve economic operation of the boiler. 1, the combustion method of determining boiler fuel gas: C02 content is determined from the flue gases and excess air ratio (1) the combustion quality (2) determines the length of the flame from the combustion quality (3) from the flame color and smoke color determination 2 is good or bad combustion, fuel combustion boiler adjustment method: the normal combustion, furnace flame stability was white orange, generally rumble, or if the flame beating abnormal sound, should adjust the fuel and air volume. If the adjusted still no improvement, it should identify the cause flameout, the measures to be taken and re-ignition.

Anyang City Power Supply Bureau as a unit in charge of the sale of electricity in Anyang City, in the choice of the 10t boiler dealer kazakhstan is more cautious. Based on our understanding and trust, choosing our split condensing steam boiler. Anyang Power Supply Bureau responsible person to us feedback, provide fast side of the boiler with the rest assured, product design everything, we believe that the fast side of the boiler can be used for more than 10 years and even 20 years. --customer feedback

wns series oil gas steam 10t boiler dealer kazakhstan for pharmaceutical factory benefits

The boiler is equipped with movable front and rear smoke box covers to make the boiler easy to repair.

The main components of organic heat 10t boiler dealer kazakhstan burner natural gas burner 5 is constructed of the following system components: 1, the function that the air supply system, air supply system into the wind speed a certain amount of air to the combustion chamber, the main components are: shell body, fan motors, fan impeller, air guns fire tube, damper controller, damper baffle, a cam adjusting mechanism diffuser plate. 2, the ignition system functions in that the ignition system ignites a mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy and other natural gas boiler manufacturers. Which facilitate saving, you can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off gas passage 3 days , system monitoring function monitoring system is to ensure that the burner safe and stable operation, the main components are flame detectors, pressure monitors, temperature monitors and the like. 4, functions of the fuel system of the fuel system is to ensure that the desired fuel burner. The fuel oil burner system are: tubing and fittings, pumps, solenoid valves, nozzles, heavy oil preheater. Gas burner mainly a filter, pressure regulator, solenoid valve, and then firing solenoid valve, the fuel valve. 5, electronic control system electronic control system command center and the focal the above system, the primary control element is a control box, with different programmer for different burners, the common programmer has: LFL series, the LAL series, LOA series, LGB series, the main difference is the time of each different program steps. The controller 1, ultra Encyclopedia Chinese LCD display, built-in luminous incandescent lamp, regardless of the day night, the screen clearly visible. 2, the image level animation display state, condition, valve status, alarm status, operation of the boiler at a glance. 3, CPU intelligent central processor, all the programs focused on a digital chip, scalability, high degree of automation, simple, and powerful. 4, includes a time setting, temperature setting, setting valve, a continuous setting, timer setting, and other control functions pressure setting, arbitrarily set the working state. 5, includes a low level alarm (anti-dry function), ultra high temperature alarm, alarm and other ultra-high pressure alarm and chain protection (shutdown), eliminate safety hazards. 6, detailed self-diagnosis, record, store alarm information, enables ready access to an alarm condition, easy inspection and maintenance.