Tel No. (+86) 371-55629010

Electric Steam Generator Electrial Boiler

Small gas steam electric steam generator electrial boiler in the hotel building applications in daily production, how to save energy and reduce the emission of pollutants, reduce costs, increase economic benefits to the business, the real problem is getting attention, and gradually resolved. Shenyang is a hotel accommodation, offices, restaurants, stores in one large commercial buildings, construction area of ​​6 × 104m2. During the heating period, heating systems, domestic hot water steam system, laundry room used by the municipal heat supply network. After the heating period, domestic hot water systems, steam laundry prepared from 2 model white WNS8-1.25-YQ fuel steam boiler (heating of serving as backup boilers) for the steam, steam production of single 8t / h. Steam boiler room to the sub-cylinder (in the basement podium) linear distance is 200m, and specifications for the steam supply pipe DN250mm, Buried employed, the compensator 4 disposed manhole. Based on the actual measured amount of steam on the hotel, and the application of energy-saving small gas steam boiler in the hotel building were discussed. Selection 2 gas steam boiler us 2009 June 7 to July 1 for steam consumption for domestic hot water systems, laundry room were measured. Average pressure of 0.08MPa steam, hot water systems, laundry average daily amount of steam were 7.43,2.43t / d. Two systems together, the maximum amount of steam per unit time and the average amounts were 0.77,0.41t / h. From the measured data, daily 9: 30-11: 30, 15: 30-17: 00 cooking gas peak, the highest air consumption is 19.65m3 / h, the hotel into the household gas pipeline gas supply capacity of 95m3 / h. According to domestic hot water, laundry room two systems unit time summer highest steam consumption is 0.77t / h, should be used in a 1t / h gas steam boiler, its gas consumption is 76m3 / h. In actual use, reasonable arrangements for gas time, can fully meet the demand for gas gas steam boiler. From the above analysis, the steam production of the hotel is much larger than the existing fuel steam boiler steam summer practical usage. According to the measured summer daily expenditure of more than just fuel costs more than 3000 yuan / d. Underground layer may be mounted on a podium 1t / h gas steam boiler, steam lines since all indoors, and therefore low cost pipeline system, and reduce the emission of pollutants, environmental protection efficiency significantly. 3 gas steam boiler room design of the hotel podium underground over 3 floors, including the basement of the original generator set oil storage has been discontinued, construction area of ​​about 60m2, close to the basement exit ramps from the gas pipeline into the family 8m, after transformation, can be used as gas heating boiler room. Gas heating boiler heating system flow shown in Figure 1. Gas heating boiler to be mounted ventilation system, the ventilation normally not less than 6 times / h, accident ventilation of not less than 12 times / h, the amount of exhaust air volume should be slightly larger, so that the boiler room space maintain positive pressure, and the ventilation should be selected proof products. Gas heating boiler to be mounted combustible gas detection and alarm devices, combustible gas detection and alarm device to automatically signal when gas leakage occurs, the emergency shut-off valve closed and to ensure that no further leakage of the combustible gas. Water spray system shall be installed, and the sprinkler system in conjunction with the original. Gas heating boiler in order to prevent water from leaking into the premises are ground floor, the ground should boiler room waterproofing and drainage ditch, the concentrated water discharged to the ground floor drainage system pressure, into the room promptly [1,2 ].

Recently, we learned, Zhangbei County, Hebei Province to speed up the transformation of low-nitrogen combustion, gas-fired, Zhangbei County Environmental Protection Agency issued the "Notice on nitrogen oxide gas electric steam generator electrial boiler governance", the transformation of the way around the gas boiler, the transformation of technology formalities to conduct a comprehensive explanation of propaganda, mobilization of Zhangbei above a certain size gas boiler units to actively participate in low-nitrogen transformation.

In order to ensure the smooth progress of work, the EPA developed a grasp of leadership, and a series of regular briefings on the system, arrange for the transformation of real-time tracking progress, personally led by the leaders in charge of the transformation of the construction-site supervision, to solve various problems during installation accelerate the transformation progress of the project. To date, more than 10 tons of steam Zhangbei natural gas boilers have been completed the transformation and detection of nitrogen oxide emissions, emission concentration all the stabilizing reached 30mg / m³ or less, over-done.

To protect the subsequent reconstruction work in depth, Zhangbei County township organization, the relevant units of the county with a comprehensive Mo Pai, gas-fired, gas-fired boilers for each specific model boiler unit, whether used and other basic information has been verified, the establishment improve the work ledger; to ensure that the base number is accurate, targeted work, Zhangbei arrange strengthen docking with the gas company, promptly verify the perfect new gas boiler archives, ensure the follow-up task of transformation clear, exhaustive renovation project. At the same time, combined with the actual development of the Zhangbei gas boiler compliance programs to lay a solid foundation for the comprehensive promotion of this work next year.

The corresponding relationship between the power generation capacity MW and the electric steam generator electrial boiler capacity of tonnage is as follows.

1. Medium pressure boiler; boiler evaporation: 75t/h; main steam parameter 3.82MPa/450°C. Supporting steam turbine generator set capacity 12MW

2. Medium pressure boiler; boiler evaporation: 130t/h; main steam parameter 3.82MPa/450°C. Supporting steam turbine generator set capacity 25MW

3. High-pressure boiler; boiler evaporation: 220t/h; main steam parameter 5.4MPa/540°C. Supporting steam turbine generator set capacity 50MW

4. High-pressure boiler; boiler evaporation: 260t/h; main steam parameter 5.4MPa/540°C. Supporting steam turbine generator set capacity 60MW

5. High-pressure boiler; boiler evaporation: 410t/h; main steam parameter 5.4MPa/540°C. Supporting steam turbine generator set capacity 100MW

6. Ultra-high pressure boiler; boiler evaporation: 440t/h; main steam parameter 13.7MPa/540°C. Supporting steam turbine generator set capacity 135MW

7. Subcritical boiler; boiler evaporation: 1025t/h; main steam parameter 14.7MPa/540°C. Supporting steam turbine generator set capacity 300MW

8. Supercritical boiler; boiler evaporation: 1900t/h; main steam parameter 26.2MPa/566°C. Supporting steam turbine generator set capacity 600MW

ZG CFBC electric steam generator electrial boiler supplier offers a wide range of world class Circulating Fluidised Bed Combustion Boilers. A modern concept in steam generators, these state-of-the-art systems are designed and manufactured for a wide range up to about 500 TPH. These boilers have multi-fuel firing capacity, high thermal efficiency, low emissions of SOx & NOx and can effectively utilize high ash coals, lignites, washery rejects, petcoke, etc.