Tel No. (+86) 371-55629010

5 Ton Coal Fired Steam Boiler for Sale

Comparison of coal-fired 5 ton coal fired steam boiler for sale and gas steam boiler? Which is more cost-effective? There will be new users are asked coal-fired steam boiler and gas steam boiler which is more cost-effective in a number of economic operation? Believed to be ready to buy a steam boiler of every business relationship or personally, with you today, I will work together to analyze these two boilers in operating costs to do a comparison. First, the first point to analyze procurement costs: Because gas steam boiler in the annex above techniques and configurations to be clear lead and coal-fired steam boiler, gas steam boiler supporting a dedicated burner, put the cost of just one burner price opened, so that the same tonnage of steam boilers, steam boilers high gas prices than coal-fired steam boilers and more. The second point to analyze construction costs: The costs mainly from the boiler room, boiler tubes of steam investment funds. Where the coal-fired steam boiler because more appropriate auxiliary equipment, so in the boiler room construction funds to be more. There is a gas steam boiler automatic control operation, and automatic alarm and automatic protection function. Connected to the gas pipeline, the burner will automatically supply costs can effectively save staff. Coal-fired steam boiler because of the need of coal on the program, so in terms of personnel expenses wage will be larger. The third point to analyze the environmental cost: major review means that the coal-fired steam boilers now more stringent. The gas steam boiler due to the operation of the economy, environmental protection and energy saving, as well as government policy to encourage more and more widely used. The fourth point to analyze the cost of fuel: coal-fired steam boiler will be much higher than the steam boilers in gas fuels. After analyzing the above four points of view on coal in order to save operating costs more than gas steam boiler steam boiler, but coal-fired steam boiler steam boiler environmentally friendly than gas in environmental protection, environmental pollution is now increasing in recent years, so the state to environmental pollution control is relatively strict, so in accordance with the requirements of environmental protection point of view has an advantage gas steam boiler.

The main characteristics of the indicators boiler What? To demonstrate configuration, capacity, parameter and economical operation of the boiler, etc., generally represented by the following indicators to the basic characteristics of the boiler. A) evaporation industrial boilers evaporation is generally 0.1 ~ 65t / h. For the hot water boiler with a nominal thermal power of its capacity to indicate the size, in units of MW. (Ii) pressure and temperature for saturated steam production boiler, just indicate steam pressure. For the production of superheated 5 ton coal fired steam boiler for sale, the steam temperature of the steam must be marked at the outlet of the superheater, i.e., superheated steam temperature, the unit is deg.] C. For hot water boiler, the hot water temperature has rated outlet and rated the import of sub backwater temperature. With rated thermal power, rated water temperature and the return temperature corresponding to the rated nominal referred circulating water flow of water through the hot water boiler, the unit is t / h. Heating boiler (iii) an evaporator heating surface and the heating surface of the heat generation rate surface evaporation rate or heating rate is an indicator of the intensity of the boiler work, the greater the numerical value, the better the heat transfer, the smaller the amount of metal consumed boiler. Heating surface evaporation rate general industrial boiler is less than 40kg / (m · h); heating surface of the heating rate of hot water boiler is less than 83700kJ / (m · h) iv) the thermal efficiency of the boiler which is an index indicating economical boiler heat, general industrial combustion thermal coal boiler efficiency of around 60% to 82%. Sometimes, in order to measure the heat economy schematically steam boiler, are also commonly used coal or coal water vapor than the ratio expressed as the ratio of the amount of coal in the boiler per unit time over the period of time and the amount of steam production. Coal-water ratio of about the size and type of boiler, coal quality and operation management quality and other factors. Industrial boilers coal-water ratio is generally l: 6 ~ 1: 7.5. Description (a) Evaporation: desired amount of steam produced per hour steam boiler called evaporation, the unit is t / h steam boiler showed that the size of the rated capacity of evaporation, i.e. in boiler design parameters and ensure a certain efficiency. maximum continuous evaporation, also known as the rated output of the boiler (ii) pressure and temperature: the rated pressure steam boiler of the steam at the outlet of the steam or the hot water boiler rated working pressure rated pressure at the outlet of the hot water boiler is called, and He said maximum working pressure, in units of MPa (iii) an evaporator heating surface and the heating surface of the heat generation rate: refers to the heating surface of the pot soft drinks and other heat transfer medium and the flue gas heat exchange area of ​​the pressure receiving member, usually with smoke metal surface area of ​​the gas-side heating area is calculated, in units of square meters. the amount of steam per hour per square meter of the resulting heating surface, called boiler heating surface evaporation rate, in units of kg / (m · h) per hour hot water boiler m² heating surface of heat generated by the heat generation rate is referred to as heating surface, the unit is kJ / (m · h). (Iv) thermal efficiency: thermal efficiency of the boiler is a boiler effective utilization percentage of the heat input and heat boiler per unit time, also called boiler efficiency, [eta] is represented by the symbol.

Henan combustion control and adjust fast boiler boiler company to introduce small series with the boiler combustion control and adjustment. 1 5 ton coal fired steam boiler for sale combustion process is the basis of all the work process of the boiler, from the safe operation of the economy, environmental protection point of view, how to properly regulate the burning furnace, saving coal consumption is the responsibility of each fireman. 2 hot water boiler combustion conditions primarily by uniformly supplying the fuel, and air distribution adjusting reasonable combustion equipment is achieved, the coordination of the three, to ensure stable combustion conditions, economy, safety. When coal and boiler load changes, will need to adjust the amount of coal feed and the amount of the wind, in order to obtain a normal combustion conditions. Indicator 3.1 normal combustion conditions 4.8.3 normal combustion means: timely fire burning strong, ash burnout. Specific requirements:. A fuel inlet from the anterior arch 0.1-0.15 m fire, gray ash ex chain at the 0.3-0.4 m burnout. B. fire bed smooth, dense and uniform flame, without flame or blown partial blackening phenomenon. C. Flame intermediate white light, two dark, the fire grate bed length representing more than 3/4 of the effective length. D. pale gray smoke or nearly colorless. In order to achieve good combustion conditions, must maintain a high furnace temperature, the temperature of the upper layer is generally burner combustion layer preferably 1100-1300 deg.] C, may be determined according to the color of the flame. Furnace temperature and flame color relationship in the following table. The outlet temperature of the furnace can also be used to determine, 29MW boiler design furnace outlet temperature of 1017 ℃, 58MW of 998 ℃. 3.3 In the case of normal combustion, the oxygen content in the flue gas is constant, the oximeter, fireman can understand the situation of excess air in the furnace, the furnace excess air is generally mechanical 1.2-1.4%, of excess air and oxygen table below. Ash 3.4 combustibles content is an important sign of good and bad conditions of the boiler combustion, which fuel, combustion equipment, and operations are closely linked, general mechanical furnace ash carbon content should be less than 10%. 3.5 water boiler operation should ensure that in the case of no condensation of the tail to minimize exhaust gas temperature, exhaust gas temperature is controlled at 110-160 ℃. Adjusting and controlling the amount of coal to a fireman who adapt to changes in load, the supply must be based on different types of coal and the various stages of the heating season, the weather trend, the thickness of the seam is determined, the general control of the thickness of 80-100mm low load, medium load control in 100-120mm, high load control in 120-160mm. 2 fireman in specifying a seam thickness, to be due to the furnace, because coal should comprehensive analysis, on balance, for the ash content, water large, large particles, high ash melting point of the coal, generally the appropriate tone thick seam, opposite seam is to tune thin. Small particles of coal or pulverized coal and a low ash melting point of the plurality coal i.e. strong bonding to a thin coal seam. Generally the 3 or the boiler when the load change is not too large, the method should not be used to adjust the thickness of the seam. Because coal seam thickness adjustment can not be effective immediately adjust the load only when a large load changes, and long-term stable operation of the boiler in the new load considering regulating coal seam thickness. 4 seam thickness can be achieved by adjusting the height of the coal and layered coal hopper shutter speed of the drum. Shutter elevation coal, coal may be added into the same hierarchical improved coal hopper drum speed may be increased into the amount of coal seam in order to obtain a proper height, the height of the shutter must coal, coal hopper drum speed stratified and chain speed adjustment of the three. Given the limited level editor, inevitable errors and inadequacies, please correct me! Henan fast Boiler Company is committed to a wide variety of gas-fired boiler, steam boiler manufacturing, product quality, reasonable prices and widespread customer industry praise, if you have any needs, please contact us!

Recently, Shaanxi Province, to build a good ecological environment, issued a "Blue Sky Battle Shaanxi Province 2019 work program", "clear water Battle of Shaanxi Province 2019 work program", "Shaanxi Province Pure Land Battle 2019 work program", "Shaanxi Castle battle province 2019 work program "and other four major environmental battle to defend the program. Details below.

"Program" is mentioned: this year by optimizing the six policies, tough fight seven games, seven strengthen security measures, the average concentration in urban areas and strive to fine particulate matter (PM2.5) fell 4 percent to ensure that the number of heavy pollution days significantly reduce atmospheric environmental quality improved significantly, people's happiness significantly enhanced blue sky.

3, increase economic policy support to accelerate clean winter heating work, in accordance with the principle of "Jiangyoufalie", the establishment of special funds for air pollution prevention and control arrangements with local ambient air quality to improve performance linkage mechanism.

1, lay the tough restructuring, according to the law closed down quit a number of energy consumption, environmental protection, safety, technology and production of non-compliance or substandard products out of production capacity, before the end of the year, the Guanzhong area basically completed "messy dirty" industrial enterprises and in accordance with regulations cluster comprehensive treatment.

2, tough fight industrial pollution control, focusing on gas-related industrial pollution sources to perform all the installation of flue gas emission standards new online monitoring facilities, the Guanzhong area cement, coke, iron and steel, nonferrous metals, glass, ceramics, tile and other industries, and to ban coal-fired hot air furnace, the coal-fired cogeneration substantially eliminated heating pipe network coverage heating, drying furnace (kiln).

4, clean energy alternatives tough fight, central heating station complete transformation of existing coal-fired clean off the area before the end of the city to clean the heating rate in urban areas off more than 90% before the end of May to complete the Guanzhong area rural village set loose coal governance indeed household inventory; motor vehicle pollution control tough fight, and increase freight railway construction investment, strengthen the construction of urban public transport system, promote high-emission motor vehicle pollution control, Guanzhong area cities and built-up area buses in the proportion of new energy vehicles to achieve 80 %, starting July 1, the province's implementation of six national emissions standards.

"Program" also pointed out that by strengthening the organizational leadership, strengthen environmental law enforcement, special inspectors carry out inspections of air pollution, strengthen grid environment supervision, improve environmental monitoring and control network, strengthen science and technology infrastructure support, strict accountability assessment 7 safeguards to ensure that work effectively.