Tel No. (+86) 371-55629010

500000 kal biomass fired steam boiler

Di 500000 kal biomass fired steam boiler safety valve installation and adjustment of safety valves for steam boilers, its importance is self-evident, its purpose is to protect the safe operation of steam boilers, when the medium pressure steam boilers or pipes increases more than the prescribed the value is automatically turned on, the steam boiler safety shutdown. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. There are heating and hot water boiler bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Safety valve is so important, then for its installation, precautions, the author based on years of experience, in particular, are summarized below. 1. The safety valve safety valve should be installed after the installation of the boiler pressure test and adjust safety valve operating pressure at the first fire. The pressure should 7≤2 provided for in section 143 of the National Bureau of Labor Table "Supervision and Regulation steam boiler safety technology" to adjust. 2. Remove the adjustment valve opening pin, remove the cover, loosen the hex lock nut, the adjustment screw is then screwed, to relax or tighten the spring to meet the required pressure exhaust valve. After adjusting tighten the lock nut, and then install the remaining components. When the valve reaches a predetermined set pressure, it should be sealed lead-sealed, unless the check valve, otherwise not allowed to remove the lead seal at any other time. First, when adjusting the safety valve, the water level should be slightly lower than normal water level of the barrel, and ready to enter the water when the safety valve is opened. Second, do not knock any part of the safety valve, the safety valve can only be opened using the valve control lever. Finally, the boiler is absolutely prohibited until the safety valve is adjusted.

Hefei Limin Pharmaceutical Co., Ltd. Nanjing Military Region, formerly the backbone of pharmaceutical companies, the main drug is slowly swallow rather teabag, relying on advanced R & D platform to carry out contract manufacturing, OEM OEM and other business cooperation. China's environmental protection development trend began to take shape, many environmental policies have been put forward for a positive response to the national environmental policy, Limin Pharmaceutical decided to introduce a gas station 500000 kal biomass fired steam boilers. After an investigation of the boiler market, Limin Pharmaceutical fast boiler is strong comprehensive strength and wealth of experience working for many years in the pharmaceutical industry to attract, party fast according to the actual needs of customers for its recommendation of one of Taiwan 4 tons of steam condensate gas-fired steam boiler (WNS4-1.25-YQ).

Pharmaceutical boiler how to correct selection? Pharmaceutical boiler how to correct selection? With increasingly stringent national environmental policy, many pharmaceutical companies increasingly began to notice how to choose the boiler, through research and analysis of the market, the 500000 kal biomass fired steam boilers in the range of pharmaceutical applications is relatively large, but the boiler only need to select the metrics solve business needs, but also reduce the operating costs of enterprises also need to have a significant contribution, then you want to meet these targets, you need to consider a number of factors, the following Xiaobian take you to do some simple understanding. Thermal efficiency is generally lower run (1) pharmaceutical boiler, heat efficiency of the boiler operation is directly related to the use of effects during use of the boiler as well as losses cost, thus making this selection, it should be carefully considered. (2) a power boiler pharmaceutical Generally, the choice of the boiler, when the boiler operating parameters understanding, we try to choose a power 20% higher than normal amounts of pharmaceutical steam boiler, to meet special circumstances special gas demand. (3) to select what type of boiler opening small series have mentioned constantly improve environmental policy, then in order to conform to the requirements of the times, many pharmaceutical companies have carried out cleaning boilers transformation, such as biomass to gas, fuel type, etc. the energy-based, but by analyzing the survey data, the application will be gas-fired boiler more certain, both from the terms of cleanliness or convenience are more suited to the application. Of course, during the selection, also we need to consider the actual situation of the boiler applications, such as space, power consumption of the local conditions selected for high efficiency boilers. In short, when pharmaceutical companies during the selection boiler thermal efficiency of the boiler efficiency, cleanliness and other factors are more important, so when choices must be based on the actual situation, more contrast analysis, careful decision-making.

Gas-fired 500000 kal biomass fired steam boilers compared to traditional heating methods advantages 1. Hot water boiler boiler assembly PC-style controller, all functions are stored on a smart chip, intelligent boiler, digitization, automation, humane, intelligent control of boiler water temperature, water temperature reached the heating automatically stop; large screen fonts display temperature, boiler water temperature at a glance. A multi-purpose furnace, while heating may be cooking, boiling water bath. 2. Super conversion system, start low temperature heat exchanger, heat transfer speed is fast. Hot water boiler boiler assembly PC-style controller, all functions are stored on a smart chip, intelligent boiler, digitization, automation, humane, intelligent control of boiler water temperature, water temperature reached the heating automatically stop; large screen fonts display temperature, boiler water temperature at a glance. 3, gas steam boiler installation cost is low, the heating safety: Universal device, without changing the heating equipment, pipes, radiators general, to achieve the water circulation heating effect; fast heating, the heating area of ​​up to 60,500 m2, the system plumbing , 24 hours of heating, long service life. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. 4. Gas steam boiler low energy consumption, low cost: a variety of materials, solar panels, solar lights, solar photovoltaic power generation inexhaustible, everywhere (eg: chaff, corn stalks, rice straw, wheat straw, sesame straw, peanut hulls , branches, sawdust, weeds, etc.). All biomass can burn agriculture and forest waste. The use of advanced technology and efficient packing gasification technology, continuous gas production, long time, once for 7 days, can replace conventional high energy heating method. It can be used to retrofit or renovation of a traditional boiler equipment. 5. safety and environmental protection: working pressure is small, does not exhaust emissions, there will be no risk of explosion, coal-fired flue gas discharge will not cause harm to people, it will not cause environmental protection. 6. widespread use, especially for the rural areas of cooking, boiling water, bathing and heating. It also applies to the boiler combustion, greenhouse heating, heating and a large area of ​​small and medium sized restaurants, and not subject to seasonal restrictions. It can be used all year round.