Tel No. (+86) 371-55629010

Seller 2t Condensing Boiler Industrial

Introduction to four problems of selecting and purchasing condensing seller 2t condensing boiler industrial!

As a new favorite of the new era, condensing boiler is not only more efficient but also environmentally friendly than ordinary gas-fired boiler. It is more and more popular with us, especially for large-family houses. However, many people are not familiar with condensing boilers, daily shopping will often encounter the following 4 major problems, let's take a look.

1, are all household sizes suitable for the installation of condensation wall hangers? Condensing boiler companies ranked top company introduction: in home applications, for only half a hundred square meters or so of the household type, is also suitable for the installation of condensation wall hanging furnace? This may be a false proposition, but the fact is that some heating companies "across-the-board" promote condensation wall hanging furnace, regardless of the size of the owner, this cost-effective account is variable, so this is a need for our specific issues specific analysis.

2, is the whole premixed must be better than the secondary heat transfer condensation? Many people in the industry will sniff at the secondary heat transfer condensing furnace as "false condensation", but the warm cube notes that the secondary heat transfer condensing heat efficiency is also more than 100%, belonging to the category of first-class energy efficiency, but the overall thermal efficiency is a few points lower than the full premix.

3, is it possible for any company to install condensing furnaces? Is it the same as installing conventional wall hanging stoves, can any company install condensation furnaces without professional training, what are the differences in installation, post-maintenance and repair aspects of condensing furnaces? when selecting and purchasing boilers, attention should be paid to manufacturers. Whether the industry organization has a supporting training or evaluation or certification system, when we select the condensing boiler company, we all need to consider these points.

4. Why are condensing boilers so much more expensive than conventional boilers? The price of condensing boilers has become the biggest obstacle to the promotion of almost every HVAC company. Looking at the current market, almost all brands of fully premixed condensing furnaces are more expensive than conventional boiler markets. Where is this expensive? Still, the question is, is your initial cost and post-maintenance cost, whether or not all household areas, all usage habits and conditions, can recover the expensive costs, and when choosing, you should look at the price list of the condensing boiler company, and for the owner, it is necessary to look at the price list of the condensing boiler company. It has made a great contribution to the national "energy saving and emission reduction".

Jiamusi City, Heilongjiang Province Tangyuan county government to further implement the "Heilongjiang Provincial People's Government of Heilongjiang Province on the issuance of three-year action plan to win the notice of blue sky Wars," the actual situation, carry out a comprehensive rectification for small coal-fired seller 2t condensing boiler industrials, as follows .

First, the objectives

By the end of 2019 out of the region to build 26 units per hour and 10 tons of steam coal-fired boilers and furnaces tea, operating a stove, food equipment and other coal-fired kiln drying facilities. Out of which 14 coal-fired heating boilers Small units, service three coal-fired boilers, industrial production of small coal-fired boilers nine. By the end of 2020, the region will build small coal-fired boilers cleared number, and completed more than 10 tons of steam per hour of coal-fired small boilers governance standards.

Second, the specific content of execution

1, source control. County-level cities built in the region 35 tons of steam per hour ban on new coal-fired boilers, the rest of 10 tons of steam per hour ban on new coal-fired boilers and below.

2, find out the base. Focus on carefully checking the area of ​​coal-fired boilers case, before the end of May, the completion of the area and the development of coal-fired boilers ledger built-up area, and clearly out of all kinds of coal-fired boilers responsible departments and completion time.

3, held a mobilization meeting. 10 tons of steam per hour, organization and small coal-fired boiler unit, responsible departments held a meeting to clear out of time limits, and invite gas companies, boiler manufacturers, heating companies and small boiler unit for docking, to help provide alternative solutions Program.

4, announced the phase-out plan. Through government websites, issued to small coal-fired boiler unit a variety of ways such as notification, publish small coal-fired boilers out of the list, time frame for completion and telephone hotlines.

5, to carry out law enforcement inspection. Organization of joint law enforcement inspection, supervision of small coal-fired boiler unit to carry out the planned phase-out time frame. Carried out errant time, press the "Heilongjiang Province Air Pollution Prevention Act," the imposition of penalties.

Note industrial seller 2t condensing boiler industrial water quality testing of water quality testing what are the considerations which industrial boilers (1) pay attention to scaling problems boiler. When carrying out inspections of the boiler water quality, pay attention to the problem of scale boilers. Boiler heating surface scaling, will not only affect the thermal conductivity of the boiler, but also can disrupt the normal structure of the boiler, affecting the normal operation of the boiler. Fouling will too concentrated so that the temperature of the steel sheet, the steel sheet could afford once over, will produce accidents. Moreover, the scale problem is a common cause of boiler accident, we need to attach great importance to staff fouling problems, do water quality testing. (2) pay attention to water treatment and work-related training of personnel. First, we must strengthen the progress of the work of the boiler water treatment, understand the importance of water treatment. Second, we must strengthen the training of staff so that it can fully understand the water treatment process. To make it have the necessary knowledge of water treatment. In particular, to strengthen the natural water, the impurities in the water for effective treatment to improve water quality. To pay attention when handling method, common in two ways, first, filtration, and second precipitation. In personnel training, to ensure that staff can master the common water quality testing methods and treatment, to master the professional knowledge, and constantly improve the quality of personnel. First, to ensure accurate test results of water quality, so as to smoothly guide the follow-up by the correct data. Second, we must strengthen the technical quality of the staff increase, so do the theory with practice. Third, the development of sound, a sound regulatory framework, the rule-based quality inspection can reduce boiler performance problems caused by poor water quality. (3) prevent boiler corrosion problems. Boiler corrosion problems need attention, which need to focus on sensitive monitoring of the boiler, the weak link in the water quality testing, monitoring whether it is corrosive. If the monitoring to corrosive media, to fully, completely clear. Taking into account the protection of the cold parts of the corrosion-prone parts of timely protection, corrosion has been the site for processing, so that you can effectively avoid the boiler cause further corrosion. (4) strengthen the supervision of water treatment. To further strengthen the supervision of the water treatment process, so as to improve the performance of the boiler, saving operating costs, reduce the occurrence of accidents. First of all, to supervise water quality around the normal operation of the boiler, to avoid adverse water quality. Second, we must strictly examine the quality of treated water in accordance with the relevant requirements, the supervision carried out, to achieve the quality supervision and inspection of the entire process. Only strengthen supervision, the implementation of routine inspections in order to truly improve the effectiveness of water quality tests.

Startup seller 2t condensing boiler industrial drum water level should be adjusted according to the change control kotelshchik conditions. Initial ignition, boiler water is gradually heated, vaporized, expanded, the water level rises, then the accident easily by lowering the water level drainage door, and the door should be periodically discharged sewage, can improve the water quality of the pot, and promote circulation; as the steam temperature the weight of steam rise, increasing the discharge of steam, should be based on the trend of drum level, replenish the water supply; red tube boiler during verification or security doors, often due to a sudden increase in steam flow, steam pressure and cause serious downhill the "false water level" and, therefore, before performing the above operation, the water level should be kept low, then increase the water supply according to changes in the flow of steam, causing the water level is too low to prevent the safety valve seat and other reasons; according to the boiler load conditions, timely switch running feed line, and in accordance with a predetermined condition, automatic water supply input.