Tel No. (+86) 371-55629010

4t Industrial Boiler Hot Selling

Why more users choose to use the condensing steam 4t industrial boiler hot selling steam condensing boilers due its advanced technology, cost-effective, good quality and other advantages many corporate users to capture the hearts and minds, to stand out in a crowd kind of boiler, gradually became a public company recognized and selected mainstream boiler. Here we have to discuss about it, and why more users choose to use the steam condensing boilers. 1, equipment maintenance and overhaul convenient condensing steam boiler with automatic identification record set failure, which is not only for the convenience of users faster queries, can also help users to quickly identify the cause of failure in the boiler, perform maintenance and overhaul. Meanwhile, local boiler easy to damage also set up inspection holes manholes and hand holes, etc., once the site of failure, the operator through the inspection hole, will be able to carry out maintenance work, very simple and convenient. 2, intelligent operating system condensing steam boiler is through the intelligent touch-screen direct operation, intuitive operation can grasp the real-time status of the entire boiler, including the boiler flame height and temperature changes in the state, can glance. And all pre-condensation heating has a variety of programs that can be directly applied. 3, reasonable structure design condensing steam boilers science has been able to have good thermal effects, lasting supply of energy, because the main reason is that scientific rationality in the structural design of the boiler. For example an energy saving and a condenser at the rear, not only can help improve the efficiency of condensation of the steam boiler, and excellent selection of panel material great protection and thermal insulation performance of the sealing steam boiler using condensing process. Thus, the reason why users are keen to use the steam condensing boilers, the main reason is obvious, not only because of the full range of condensing steam boiler technology to improve the performance of outstanding features, energy saving and pollution-free and does occur in the use and supply sufficient heat, and on the repair and maintenance of the entire device is very convenient to be able to quickly deal with the problem by past record.

ZG 4t industrial boiler hot selling’s products such as boilers and autoclave are very popular in overseas markets, and there are many reasons for them. A boiler is a large-scale energy conversion device that many companies look for when buying a boiler. ZG boiler is a popular boiler manufacturing brand, and ZG boiler has successfully provided products and services to more than 10,000 customers. ZG boiler attaches great importance to R&D and innovation, and has scientific research cooperation with more than 10 well-known scientific research institutions such as the Chinese Academy of Sciences and Tsinghua University. ZG boiler has nearly 400 high- and medium-level R&D technicians and more than 130 invention patents (including utility models).

To build greener homes, recently, the ecological environment of the Office of Hebei Province issued "on improving air quality guidance on the implementation of regional differentiation of access environment." "Opinions" clearly states: Shijiazhuang, Baoding and other eight cities as a red zone atmospheric transmission channel, a ban on new industrial projects and expansion of 10 large iron and steel, thermal power, cement and so on.

"Opinions" also pointed out that the province's administrative regions and the municipalities and districts male An District, Dingzhou City, Xinji City administrative area, is strictly prohibited new construction, expansion (except for cogeneration and the same amount of alternative projects) coal; a ban on new , expansion of production capacity of iron and steel, cement, plate glass, petrochemicals project (excluding off-site relocation of upgrading) and 35 tons of steam coal-fired boilers; prohibit new emissions intensity below the access conditions of other industrial projects.

Handan, Xingtai, Shijiazhuang, Baoding, Langfang, Tangshan, Dingzhou, classified as a red zone xinji atmospheric transmission channel. Within this administrative area (except city back removal capacity), to prohibit new and expanded (except equivalent replacement) steel, thermal power (except CHP), coke, cement, lime, gypsum, fertilizer, general casting of ferrous alloys, iron alloys smelting, carbon, other industrial projects using coal as a fuel; Jing Kun high-speed east, north wing black high speed, and Langfang, Baoding and Beijing bordering county area designated as coal ban areas, not in addition to the approval of central heating coal-fired project.

Future, Hebei Province, will strengthen self-examination, government oversight and something in the ex post regulation, the implementation of various construction projects of environmental protection requirements as well as changes in environmental quality, pollutant emissions such as the implementation of dynamic monitoring of the implementation of environmental access requirements for non-construction strictly punished according to the law project, supervise the rectification of the problem is serious, shut down or banned. Meanwhile, according to relevant laws and regulations, environmental protection requirements and regional environmental quality changes and other regional differentiation environmental access requirements will be adjusted in due course.

A 4t industrial boiler hot selling water testing methods) and storage of water samples taken 1, depending on the volume of water analysis items, only a simple analysis of water samples is generally 500 to 1000 ml. 2, the sample container should be filled with water using a rigid glass or plastic bottle. Never use of wood, paper balls, metal plugs and maize. 3, sampling Note Samples should be slowly into the bottle, it can not produce water rippling. When the water sample into the bottle 10 ml shall be left void, or to prevent the water temperature changes, the cork pushed open. When averaged water sample must be taken at the same time under the same conditions. Determination of the hydrogen ion concentration in water (B) PH value of which depends mainly on the carbon dioxide, bicarbonate ion content of between opposing sulfate ions, but also somewhat affected by other ions. Whichever it is usually expressed negative numbers. Symbol "PH". PH = log [H +] measured PH value method has potential method and colorimetry, only the chapter describes the more common potential method. PH value of measured potential method, the potential difference between the solution is indicated in the measurement and reference electrodes difference generated. The potential of the reference electrode is constant, the potential of the indicator electrode with different PH value of the solution is changed. Thus the electromotive force consisting of a battery can be measured accurately with the compensation method. Using PH PH meter can be directly measured value of the solution. The procedures for measuring PH meter may be used, accuracy of 0.01. (Iii) Determination of calcium measured calcium EDTA volumetric method widely used in the PH> 12 in an alkaline solution, by EDTA titration, acidic chrome blue K- Naphthol Green B as an indicator, titration end point from red to blue 1, a reagent filter paper was immersed in Congo red 0.1% Congo red solution, soaked until removed, and then dried in air, and then cut into 1 × 1 cm pieces of about. Ammonium hydroxide - ammonium chloride buffer solution (pH 10.1) was weighed 67.5 g of ammonium chloride dissolved in 200 ml of water, was added 570 ml of ammonium hydroxide diluted with water to 1000 ml. Weigh calcium standard solution bake for 3 hours at 105 ~ 110 ℃ pure carbon 1.2485 g of calcium beaker, calcium carbonate solution to dissolve just finished boiling rush carbon dioxide with dilute hydrochloric acid. After cooling, into 1000 ml flask, diluted with distilled water to the mark. This solution was 0.5 mg per ml of calcium ions. Tetraacetic acid disodium (EDTA) disodium EDTA weighed 2 g, dissolved in 1000 ml of water to dissolve a little heat, pressing calibration method: lessons per ml standard solution containing 0.5 mg of calcium ions 5 to 10 ml, in a dry 250 ml Erlenmeyer flask, diluted with water to about 50 ml, analysis by calibration procedures; calculated equivalent concentration: where: N - equivalent concentration of calcium standard solution consumed V1-- EDTA titration standard EDTA standard solution few ml solution; the total solution milliliters V - C - 1 ml of the number of milligrams of calcium standard solution of calcium; 20.04-- equivalents of calcium. K-- Acid Chrome Blue mixed indicator naphthol green B; 0.5 g, said acid Chrome Blue K with 1 g of naphthol green B, was dissolved in 5 ml of ammonium hydroxide in PH10.1 - ammonium chloride buffer solution (preparation method see the measurement of magnesium), and add a little hydroxylamine hydrochloride, water was added to 100 ml shake. 2, Procedure Pipette 50 ml of water and 100 samples, 20% sodium hydroxide solution was added 2 to 3 ml, acid chrome blue K-- naphthol green B 2 drops of mixed indicator, titrated with EDTA standard solution changed from red to blue is the end note of the consumption of EDTA standard solution, preservation solution for the determination of magnesium. Calcium content of the sample is calculated as follows: wherein V1-- Titration standard solution consumed few ml EDTA; N - equivalent concentration of EDTA standard solution; V - sample volume, ml. (Iv) the PH10 determination of magnesium in the solution to acid chrome blue K- naphthol green B as indicator titration with EDTA standard solution of calcium, magnesium content. It titration end is blue. Then subtracts the subtraction to yield a calcium content and magnesium content. It may be in solution after titration calcium, magnesium measured continuously adjusted PH value. Assay (e) the sulfate (gravimetric method) with barium sulfate to form sulfuric acid in an acidic solution precipitated barium. Obtained from the sulfate content by weight of barium sulphate (sample when large water content, with hydrochloric acid in advance to be evaporated to dryness, the sulfate measured by the steps below to root damage nitrate: 100 ml water samples taken transparent, injection 250 ml beaker, and 1: 1 solution of 2 ml of hydrochloric acid, heated to boiling, hot slowly added under stirring 10 ml of 5% barium chloride solution, incubated for 2 hours on a water bath or sand bath, or overnight, and then quantitative filter paper with a dense, washed with hot distilled water until free from chloride ions (checking with silver nitrate solution) so far. the precipitate was dried together with the filter paper, into constant weight porcelain crucible, carefully ashing furnace set temperature, calcined at 850 deg.] C to constant weight sulfate ion content of the following formula: sulfate (mg / l) = formula weight of precipitated barium sulfate in W-- (mg); V - measured as the volume of water samples . 1.gb6903-1986 standard boiler water and cooling water measured analysis General 2.gb/t14415-1993 boiler water and cooling water 3.gb/t6908-1986 analysis of the solid matter boiler water and cooling water conductivity analysis Determination 4.gb/t6904.1-1986 pot Determination of mercuric nitrate boiler water and cooling water 6.gb/t14419-1993 Analysis 5.gb/t6905.3-1986 boiler water and cooling water chlorides Analysis Analysis water and cooling water ph glass electrode method of measurement Determination of hardness 8.gb/t6909.2-1986 boiler water and cooling water analysis method for measuring hardness 7.gb/t6909.1-1986 boiler water and cooling water Determination of alkalinity high hardness low hardness 9.gb/ Determination t6913.2-1986 boiler water and cooling water analysis Determination of total inorganic phosphate boiler water and cooling water 10.gb/t6913.4-1993 phosphate phosphate analysis